Michael from Claremont, CA
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Pliers, Socket set
Parts Used:
Top part of agitator (auger) was not turning
Using kit 285587 was straight forward. Removed fabric softener dispenser & sealing cap. It took more time to find the socket set (needed a 7/16 socket) with a long driver (10 inch) than to unscrew & remove the auger & agitator.
Cleaned up the bowl whilst it was apart (good buildup of junk under the agitator). Replaced agitator, new thrust washer to find that grease should be applied but isn't included in kit (get part not 350849). Grrr.... Applied new auger, cam, dogs and holder. (No instructions in kit for assembling cam, dogs & holder, but you can work it out ok). Applied new bolt & washer, new seal on cap. Installed fabric softener. Could have been a 15 minute job but peace and quiet in the garage makes it worthy of taking longer ;-)
170 of 194 people found this instruction helpful.