Replaced under hood surface light bulb
Very easy to replace. This replacement part is the perfect fit for my microwave since the original part has been discontinued. It does have the night light and bright light feature.
Parts Used:
HALOGEN LAMP
  • Dottie from NEW MILFORD, CT
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The part was burnt and was causing sparking inside the microwave
Removed the old canopy mica, it has tabs that slip into slots on the top of the microwave. Then installed the new part, the tabs are inserted into the same slots.
Parts Used:
Microwave Canopy Mica
  • Bill from MAGNOLIA, TX
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Microwave not turning on. All other functions operate
DISCONNECT THE POWER CORD and discharge the capacitor
Leave unplugged overnight
Remove vent grille by removing the 2 philips screws
Remove the LED panel by removing 1 phillips screw
Disconnect all connectors that plug into back of the LED board completely
Remove the wires from the switches (3) at the inside edge of the microwave door
Gently remove each switch housing and test all three switches for continuity
Carefully replace non-functioning switches and reassemble the panel
GOOD LUCK
Parts Used:
Primary Door Interlock Switch
  • Tom from DENVER, CO
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Turntable motor was making noise
Unscrewed and dropped the bottom panel of the Advantium on its rear hinge, disconnected the light and the motor, removed the motor screws, and replaced the motor. Very simple.
However, not related to the Advantium or the motor, trim had been applied to the bottom of the wall cabinets after installation of the Advantium. This trim prevented the lowering of the panel (and future removal of the whole oven), so I had to chisel and file and repaint the trim to get it out of the way.
Parts Used:
Motor, Turntable
  • Allan from LOUISVILLE, KY
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Frost build up on bottom to ice bin and delivery chute in door creating ice blockage
Remove the ice bin.
Turn the ice maker selection to "OFF"
Use small flat blade screwdriver to open the plastic ears on the electic plug in connectiion
Use #2 Phillips screwdriver to remove the screw on the front left side of the ice maker
Pull the ice maker forward until free of the two studs in the left side rear of the freezer wall
Check to see if the supplied water chute is the correct size for your application, if not remove the water chute from the old ice maker and place it on the new one.
Place the new ice maker in the freezer connecting the slots on the left read with the studs on the left wall
NOTE; IF THE ICE MAKER DOES NOT APPEAR TO BE LEVEL HORIZONTALLY REMOVE IT AND CAREFULLY REINSTALL IT TO ACHIEVE LEVEL
NOTE: ENSURE THE WATER DELIVERY TUBE RESTS IN THE RECEIVER TRAY
Reconnect the electrical plug ( needle nose pliers may be helpful in aligning the male plug with the female plug)
Move the selector from "OFF" to "ON"
Replace the ice bin and close the freezer door
Parts Used:
Microwave Fuse
  • Ronald from PONCA CITY, OK
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
the TCO is a temperature fuze on the side of the exhaust outlet. When the exhaust registers too high a heat temperature the fuze blows and stops the entire unit from working.
I replaced the TCO (fuze) through the vent opening after removing the vent cover and several small panels with a screw driver for visible access.. Some of the screws require a small offset screwdriver because of the limited access. I did not have to drop the unit from the wall over the range and was able to access through the vent opening to replace to failed TCO with a new one. The TCO is wired in-line with the power and other fuses to the unit and when it fails the enitire unit is cold with no power to lights or function of any kind. The GE service rep. said that the unit needed a new smart board but that was not the problem and they are no longer made for the older unit. I discovered the repair by looking at YouTube for repairs for the GE Advantium 120 microwave/convection combo unit.
Parts Used:
THERMOSTAT
  • James C from ARLINGTON, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Bad door switch and divide
Remove upper grill, then control panel, then 2 screws hold door switch mounting bracket, that will let you roll the switches out to work on them. Remove each switch by carefully pushing back retainer clips. Diode a long pair of needlenose pliers is helpful. The control board in front of capacitor comes out with a flat screwdriver and pry up. Removing grnd wires helps
Parts Used:
Diode Cable Monitor Interlock Switch Primary Door Interlock Switch
  • Robert from COLORADO SPGS, CO
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
3 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Blank LCD screen
.Shut breaker to microwave
. Remove two screws on each side of microwave cabinet frame holding it to the wood frame
. Get assistance in pulling microwave out of cabinet
.unplug power cable before pulling microwave completely out of cabinet
. Microwave has two separate panels top and sides removed all screws around frame along the door and sides
. Remove top steel panel
. Remove sides
. Locate screws around the electrical board screen just behind the front cover
. Use small flat head screwdriver to move plastic fasteners on each side of the electrical to release the board.
. Identify the LCD screen board and remove two screws on each side unplug the wire harness from the board.
. Lift LCD board off the two set pins
. Replace board
. Replace screws
. Plug harness back into board
. Reassemble electrical board back into display panel. Pay attention to re-engage the two plastic clips before replacing screws.
. Once panel is completely replaced.
. Resemble all panels in reverse order
. Test microwave before installing unit back into cabinet.
Parts Used:
Digitron
  • Ezequiel from Lithia, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Door Switch went bad, Internal Fan would run every time you open the door
Unscrewed the control panel (2 screws), lift up and let hang, with a plan screwdriver open bracket holding the switch, unplug 2 wires, replace with new switch, plug in the 2 wires, push switch back into bracket. Then slide on the control panel, put the 2 screws back. Easy fix.
Parts Used:
Primary Door Interlock Switch
  • gilbert from TOMS RIVER, NJ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The unit would run when the door was open!
First I had to accept the fact that the unit was designed to keep non-professional people from doing any repairs. The switch was installed in such a manner that I had to break the mounting to remove the switch, then drill a hole in the mounting to secure the new switch in place.
Parts Used:
Primary Door Interlock Switch
  • Mike from BLUFFTON, SC
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Pliers, Screw drivers, Socket set, Wrench set
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Burned out magnetron
Removed cover
Disconnected capacitor from old magnetron
Removed old magnetron
Installed new part
Connected capacitor
Reinstalled cover
Parts Used:
Microwave Magnetron
  • Dewey from MADISON, AL
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Microwave would not heat up
Part just snapped into place and wires were reattached.
Parts Used:
Primary Door Interlock Switch
  • Suzanne from POWELL, OH
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
MOTOR STILL DOES NOT TURN
PER YOUR INSTRUCTION
Parts Used:
Motor, Turntable
  • Robert P. from DEDHAM, MA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Canopy Mica broke off piece that secures to the top of the micro
Slips in easily. Line up the tabs with the brackets and pop in.
Parts Used:
Microwave Canopy Mica
  • Kathy from SARASOTA, FL
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Not heat
-unplug
-remove top and front covers
-unplug wire connectors from heating assembly
-remove heating assembly from metal stand and push out of the way
-remove metal stand from dry
-pull out heating assembly
-install new one in reserve order
Parts Used:
Microwave Fuse
  • Kip from POWELL, OH
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Socket set
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the CSB9120SJ1SS