noisy evaporator fan motor
Replaced evaporator fan motor, and this solved the whistling noise that had developed. Reviewed and followed the removal and installation instruction video as closely as possible. This was very helpful, with a few additions. For the model PS123NGPBBB GE refrigerator/freezer, there were a few differences from the video. There a was an additional cover panel that was positioned vertically at the back of the freezer compartment below the auger motor assembly. It was necessary to remove this cover (4 screws) to gain access to the auger motor cover screws. The unit also has a different light configuration with 2 lights. I found it helpful to remove these light bulbs and the corresponding light fixtures in order to remove the evaporator motor assembly. As mentioned in the video, it was necessary to cut the 4 wires from the wire harness of the new motor, and use butt end connectors to reattach these wires to the corresponding wires in the unit. Total job took between 1 and 2 hours, and the motor change solved the noise problem.
Parts Used:
-
Russell from GLEN, NH
-
Difficulty Level:Easy
-
Total Repair Time:1- 2 hours
-
Tools:Screw drivers, Socket set, Wrench set
2 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
ice maker was running over
removed the back cover, removed one srew that held the valve, disconnected water lines, and installed the new valve. Piece of cake!
Parts Used:
-
Randall from Spurgeon, IN
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver
2 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water Valve Isn't Work
I put the water hoses out the valve and put the hoses back in new valve after that put the valve in the same place with the nutdriver. When refrigerator take the temperature inside, the ice began really easy. Thank you.
Parts Used:
-
LUIS from MIAMI, FL
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Nutdriver, Screw drivers
3 of 5 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice Maker Not Making Ice
My GE SideBySide fridge stopped making ice. The green LED light on the icemaker was not blinking. The water dispenser worked fine. Fridge is only 5 years old. Freezer temp set at 7 degrees...fridge at 37 degrees. I have been using these temps since new. GE hotline suggested freezer temp should be at zero degrees. That did not work. Second call suggested an airflow issue within the freezer...there should be 1 inch space between food and back wall. Still no ice. The water valve looks to be the issue. I ordered it and got it in 2 days. Valve is in the back bottom, refridgerator side. Push the white collars around the water hoses...Then pull the hoses out. An adjustable wrench removes the nut for the inlet hose. Disconnect 2 electrical plugs. Be sure to push the water hoses fully into the new valve. I pulled the white collars out a bit to insure a tight fit. I was surprised at how simple this was to install. As it turns out, I was still getting no ice. I ordered a new ice maker and now I'm getting ice. The icemaker was EVEN EASIER to install.
Parts Used:
-
Kevin from Alhambra, CA
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers, Wrench (Adjustable)
3 of 5 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Squeky Evaporator Fan
-
Douglas from LAFAYETTE, LA
-
Difficulty Level:Really Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Screw drivers
2 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Change odor filter
Remove odor filter cover...pull out filter...replace new filter...replace cover...So easy a caveman could have done it...
Parts Used:
-
Fred from Sumter, SC
-
Difficulty Level:Very Easy
-
Total Repair Time:Less than 15 mins
2 of 3 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
was not able to get water out of the dispenser or the ice maker
Very simple fix. Just remove the back cover, unscrew the water valve, unplug the water valve and disconnect the water line. Then reinstall the new one. Takes about 15 to 20 min and it worked like a champ
Parts Used:
-
Darren from Riverside, CA
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver, Socket set, Wrench set
2 of 3 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Defroster fan burned up
First I removed the ice tray rack lifting it out of the way to reach the back cover of the fan. Then, the whole back inside panel had to be removed. Two screws removed the fan and bracket from the freezer unit. The missing bumper lid just snapped into place. Replaced everything in reverse order. Pretty easy job.
Parts Used:
-
Peter M. from Lincoln Park, NJ
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver, Pliers, Screw drivers, Socket set
3 of 6 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water dispenser inoperative
Replaced Double Outlet Water Valve then defrosted coiled plastic water tubing at bottom position inside refrigerator into pan of hot water for 10 minutes. Water still did not flow. Defrosted refrigerator and water dispenser immediately resumed operation. Suggestion -
defrost refrigerator first.
defrost refrigerator first.
Parts Used:
-
Gregory from The Villages, FL
-
Difficulty Level:Really Easy
-
Total Repair Time:1- 2 hours
-
Tools:Nutdriver
2 of 3 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
No water to dispenser or ice maker.
Replacement valve fit perfectly but didn't fix the problem. More troubleshooting found blockage through the water filter assy although I don't use a filter and just have the the bypass plug installed...7 years like this. Used compressed air to blow out the line and got some crud out. Works now but can't turn water pressure up full or line hammers and stops flow. Left supply valve open slightly which supplies ice maker fine and dispenser ok. Must be something wrong with internal spring stopper in filter assy...keeps water from pouring out if filter or bypass not installed.
Parts Used:
-
Joe from Irmo, SC
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:1- 2 hours
-
Tools:Nutdriver, Pliers, Screw drivers, Wrench (Adjustable)
2 of 4 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
My son's Refrigerator
I started out replacing a bad thermostat, no problem,
when I hooked up the water, I found that the water resovior had a leak.
I replaced the resovior, easy fix, but I had to buy two 5/16 brass couplers.
then I found that the box would not get below 10 degrees, and the suction pressure was very low.
I figured that the fan motor was burned out, so I opened up the access covers, the fan motor was hanging there with broken mounts, so I replaced the motor, and repaired the mount.
Everything works great now, The parts shiping was very fast, I was impressed.
I thought I was going to get away without fixing everyones
HVAC problems when I retired.
Friends and family still remember that you are the HVAC man.
Tom
when I hooked up the water, I found that the water resovior had a leak.
I replaced the resovior, easy fix, but I had to buy two 5/16 brass couplers.
then I found that the box would not get below 10 degrees, and the suction pressure was very low.
I figured that the fan motor was burned out, so I opened up the access covers, the fan motor was hanging there with broken mounts, so I replaced the motor, and repaired the mount.
Everything works great now, The parts shiping was very fast, I was impressed.
I thought I was going to get away without fixing everyones
HVAC problems when I retired.
Friends and family still remember that you are the HVAC man.
Tom
Parts Used:
-
Thomas from Brentwood, CA
-
Difficulty Level:Easy
-
Total Repair Time:More than 2 hours
-
Tools:Nutdriver, Screw drivers, Wrench (Adjustable)
2 of 4 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Loud whirling noises when the motor started up, then they subside (and stop) in a short time
I have not yet done the repair. After watching this repair video two problems came to mind. First I only ordered one grommet not knowing that there were two (or more I don't yet know). The second problem is that this video must be for a fridge from like the 1940, but it looks NOTHING like mine from 2008. The manual shows a bazillion parts and frankly I'm just a wee bit afraid to get started, and I am generally very handy, buuuttttttttt I don't know about this one
Parts Used:
-
Randy from VALLEY CENTER, CA
-
Difficulty Level:Very Difficult
-
Total Repair Time:More than 2 hours
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fan was not centered in the middle of the back panel opening.
Bent the motor bracket down, then using a rat tail file, elongated the holes in the back panel of the refrigerator to secure the fan in the "centered" position. This was a problem that was with the refrig. since it was made. The parts involved were perfect. NO problem at all installing them.
Parts Used:
-
James from GREENSBORO, NC
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Screw drivers, Socket set
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Opend freezer door and found ice everywhere from dripping ice maker. Even with power unplugged water was still leaking through so I determined it must be the water valve at the back of the fridge that had failed.
Unplugged fridge. Shut off the water supply valve under sink. Removed lower access panel at back of the refrigerator (six screws). Removed single green screw holding water valve bracket and pulled assembly out to access wiring and hoses. It is a dual valve as one valve is for the water dispenser and one is for the ice maker. Disconnected the 2 electrical connectors (one for each valve). Unscrewed the compression fitting for the water inlet with 1/2 " wrench. Then the two water lines on the outlet which are quick disconnects. You must push the ring towards the valve and then the tubing can be pulled out by hand.
Reattach everything to the new valve and install and its ready to use.
Reattach everything to the new valve and install and its ready to use.
Parts Used:
-
Doug from Madison, WI
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Socket set, Wrench (Adjustable)
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Bottom of refrigerator wouldn't coool
I removed the top vent and unplugged the ice machine ,took the back cover off the freezer.Removed the old fan which was pretty easy(unplugged it after I took the housing out for easy access) I plugged the new fan in and put everything back in the order I took off, and yada yada yada we have cooling.
Parts Used:
-
Charles from El Dorado, AR
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver
2 of 4 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!