my refrgerator stopped cooling and freezing
Take the cardboard grill off the bottom of the back it is held on with 5-6 hex head screws. Located the voltage inverter on the tank. It's on the bottom left of the refrigerator. Removed the screw that holds it in place.Remove the jumper wires at the quick connect. Rotate the voltage inverter and removed it. Check the voltage at the plug in going to the voltage Inverter. It should be 115-125 volts. Plug in the voltage inverter to the Quick connect away from the tank check the voltage on the side that would be connected to the tank. If both sides don't read at least 115 volts the inverter is bad. Order a new on and reinstall in the reverse order.
Parts Used:
Refrigerator Inverter Kit with Jumpers
  • Mike from Aguilar, CO
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
12 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Dorr stop was broken when door was allowed to swing too hard.
I removed the two screws which released the door stop. I then put the new door stop in place and installed the two screws. Job Done.
Parts Used:
Screw - 10-16 Door Stop - Black
  • Mark from Frederick, MD
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Wrench set
17 of 28 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Internal light switch was sticking
Two tabs hold the switch in place. I used a plastic wedge to remove the switch. Removed and replaced the two connectors held in by friction. Painless.
Parts Used:
Light Switch
  • John from Vallejo, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
13 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broken freezer light switch
Part arrived very fast as ordered..need to pry old switch out from top..use care to push the retainer down..after old switch was 1/2 out, I used a putty knife for better leveridge.Remove wire connector...after plugging in the wire connector to the replacement switch, make sure the switch is properly positioned so the switch will depress when door shuts.
Parts Used:
SWITCH LIGHT FZ
  • James from Goshen, KY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
14 of 20 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
High pitch noise
My GE refrigerator emitted high pitch noise a short while ago. I tried different dampening methods that helped but not eliminating the problem. I finally replaced the fan, motor, and associated parts and solved the problem. The total cost was about $50.
Parts Used:
EVAPORATOR FAN BLADE Compression Ring Evaporator Fan Grommet - Grey Dust Cap
  • Bert from Audubon, PA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
15 of 24 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Flapper was stuck open. Old and warped.
Replaced flapper
Parts Used:
Dispenser Door Assembly or Flapper
  • James from Virginia Beach, VA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
16 of 27 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broken Switch
Just pop the old one out, careful not to lose the wiring inside the ref wall & popped the new one in.
Parts Used:
Light Switch
  • ron from hermitage, TN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
11 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Overflowing ice maker creating glacier on back wall
No instructions came with the replacement control board. A notice that this part supercedes the original circuit board part number would have been helpful, although it is noted on the web site IF you drill into the parts list deep enough. Diagrams on the web site gave a general location for the circuit board.

Swap-out of the boards was relatively easy, although some of the connectors were reluctant to separate.

The new control board solved the overflowing ice maker issue.
Parts Used:
Main Control Board
  • Richard from Florence, OR
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
14 of 22 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
going from warm to to cold
i used the video it showed on the site or iwould not have been able to do it
Parts Used:
Evaporator Thermistor Clip
  • roy from spring hill, KS
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver
16 of 28 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Interior light needed replaced
Unplugged the appliance for safety. Removed two 1/4" screws that held the assembly in place. Carefully removed the wire guard that retains the glass shield. Unscrewed old light bulb and replaced with new part. Reversed the steps after cleaning glass cover.
Parts Used:
Light Bulb - 40W
  • Leo from TWIN FALLS, ID
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
15 of 25 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Twice I ordered the oven light bulb & each time the light bulb was defected
I had to call for a appointment for repair with GE Appliance because I thought then it . .was something electrical. The technician came out & checked everything out, turned out it was not electrical, The technician went out to his truck got a light bulb from his truck, put it in & it worked. It cost me $121.00 for trip charge from GE appliance for a light bulb that worked, your light bulbs were defective twice. Very disappointed with your products, cost me alot of money for a good light bulb thru GE appliance
Parts Used:
Light Bulb - 40W
  • Barbara from BELLEVUE, WA
  • Difficulty Level:
    Very Difficult
  • Total Repair Time:
    Less than 15 mins
14 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Feezer door would not always seal
Because the lever was broken, when you close the refrigerator door, the freezer door would unseal slightly causing frost to build up on the inside and outside of the door.

After removing the base grille, the repair was made by simply placing the new part in the slot where the old part was then re-attaching the spring from the part to the hook in the base of the refrigerator. Now replace the base grille with the two screws. Time: About 10 minutes. Tools: Phillips screwdriver, needle nose pliers.
Parts Used:
Freezer Lever - Black
  • Larry from Columbia, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
11 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
replacing ice maker drive dispensing cup
followed instructions already posted on your website, but had a very difficult time getting the dispensing side of the auger assembly to slide out, even after I disengaged the plastic tabs. There is no easy way or place to grab the assembly to pull it out. Finally turned the unit upside down and pounded on the edges of the assembly with a wood block and a small hammer. Once the part started coming out a couple of inches, I flipped over the ice bin and was able to pull it out the rest of the way, once I had something to grab on to. After the auger assembly was out the cup replacement was easy per posted instructions and the unit snapped back together easily.
Parts Used:
Ice Dispensing Drive Cup
  • David G from Walpole, MA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
11 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Icemaker flap not closing, frosting up
Watched video, however could not get outer casing off. Under the panel are three small holes, pushed up with an Allen key, used a small screwdriver to wedge out, came out easily, followed instructions from video on removing and replacing solenoid
Parts Used:
Dispenser Door Solenoid Assembly
  • Graeme from Sarasota, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
9 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice would melt intermittently creating an ice wall on the back or side of the freezer.
Replacement of the Main Control board was relatively easy, although some of the connectors were reluctant to separate.

The new control board appears to have solved the problem.
Parts Used:
Main Control Board
  • Don from Herndon, VA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
12 of 19 people found this instruction helpful.