Washer leaked at water inlet valve
The part was fine,except for one problem. The screw holes in the part were too small for the sheet metal screws. After several minutes of trying to get the screws to turn, I got a small round file and enlarged the holes until the screws fit. Luckily for me, I've had to do things like that before. Otherwise, the installation was straightforward. And the washer no longer leaks!
Parts Used:
Water Inlet Valve
  • Joel from Eugene, OR
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Worn out belt replacement
First unplug power cord and removed water hoses, then removed rear panel of machine. Shop-vac old debries out of machine Remove small spring holding belt tensioner pulley assembly. Remove hex key from motor shaft that connects to the pump. Use pliers to spin clamps out of way so you can then remove the (4) four bolts that hold pump to bottom of the motor, no need to remove other pump bolts. I used a straight screwdriver to pry the pump loose from the motor shaft to slip the old belt out of the machine. Put new belt on and reversed process for reassembly. :Note: Shop vac up water that leaks out of pump when you remove the 4 bolts, also wipe down pump so you can check for leaks after tightening pump back onto motor.
Parts Used:
BELT
  • DAVID from WAPAKONETA, OH
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers, Screw drivers, Socket set
Was this instruction helpful to you?
Thank you for voting!
cold water continued to run and water leaked all over garage floor
The original inlet valve comes in from the rear and the replacement inlet valve mounts horizontally and this will not allow the use of the valve mounting plate and I needed to make a new plate so the supply hose could mount. After making the new plate and having the supply hose attach vertically, the system appears to be functioning properly. Having to make a new mounting plate was an unexpected adventure!
Parts Used:
Water Inlet Valve
  • Gary from Porter, ME
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!