DFE28JMKCES General Electric Refrigerator - Instructions
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Refrigerator water filter replacement.
I followed the directions included with the water filter and it was simple. The only problem I had was not being strong enough to easily remove the old filter. I did accomplish that after a few tries and the rest is history.
Parts Used:
-
Sheryl from SAINT LOUIS, MO
-
Difficulty Level:Really Easy
-
Total Repair Time:30 - 60 mins
3 of 4 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Would not dispense water or make ice.
Pull the fridge out from the wall.
Close the water supply valve.
Unplug the appliance.
Using a nutdriver , remove the panel at the lower rear. Set aside.
Disconnect the water supply line from the solenoid valve.
Using the nutdriver, remove the defective water valve.
Disconnect the electrical connector noting orientation.
Remove the black safety device from the valve where the quick connect line goes to the dispenser. Depress the ring on the fitting and remove the gray dispenser line.
Discard the defective valve.
Insert the dispenser line into the quick connect fitting on the new valve. Ensure that the line goes all the way into the fitting.
Reconnect the electrical connector.
Install the valve and connect the supply line.
Reinstall the panel.
Open the supply line valve.
Plug in the refrigerator.
Test. There well be some gurgling as water refills the system.
If no leaks and water dispenses properly, push the fridge back against the wall.
Enjoy!
Close the water supply valve.
Unplug the appliance.
Using a nutdriver , remove the panel at the lower rear. Set aside.
Disconnect the water supply line from the solenoid valve.
Using the nutdriver, remove the defective water valve.
Disconnect the electrical connector noting orientation.
Remove the black safety device from the valve where the quick connect line goes to the dispenser. Depress the ring on the fitting and remove the gray dispenser line.
Discard the defective valve.
Insert the dispenser line into the quick connect fitting on the new valve. Ensure that the line goes all the way into the fitting.
Reconnect the electrical connector.
Install the valve and connect the supply line.
Reinstall the panel.
Open the supply line valve.
Plug in the refrigerator.
Test. There well be some gurgling as water refills the system.
If no leaks and water dispenses properly, push the fridge back against the wall.
Enjoy!
Parts Used:
-
George from GEORGETOWN, DE
-
Difficulty Level:Very Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Nutdriver, Wrench (Adjustable)
3 of 4 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
broken door shelf
-
James from SUN LAKES, AZ
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
2 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The freezer started icing up and the freezer drawer guide broke
I was able to repair both problems for a cost of about $6.00 thanks to parts select. Will definitely be back for more parts when I need them. Great selection and rapid shipping.
Parts Used:
-
Louanna from RICHMOND, VA
-
Difficulty Level:Really Easy
-
Total Repair Time:30 - 60 mins
2 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer door handle broke off from constant pulling breaking the freezer air seal.
I attached the new handle and tightened the set screws with an Allen wrench. Piece of cake!
Parts Used:
-
ROBERT from NORTHRIDGE, CA
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Wrench set
2 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Low water flow from the dispenser.
Replaced the water solenoid that has a filter/screen as part of the unit.
Removed the back bottom plate. Turned off water supply, removed hose from water valve. Removed valve assembly, and un-pluged wiring. Installed new unit reverse of removal
Removed the back bottom plate. Turned off water supply, removed hose from water valve. Removed valve assembly, and un-pluged wiring. Installed new unit reverse of removal
Parts Used:
-
Donald from PIONEER, CA
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver, Pliers, Wrench (Adjustable)
2 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Lights in the refrigerator were very dim
I determined one of the five LED lights in the refrigerator was dead by swapping it with a working one. The refrigerator lights are wired in series and if one of the lights is dead the remaining ones turn on, but very dim. I called PartSelect.com and thanks to their help we determined the correct part to order which is the oval-shaped cover LED assembly which includes the cover, LED, and female connector. The part from PartSelect arrived in three days. The oval-shape LED plastic Cover assembly is mounted on the refrigerator and held by a couple of side latches. First unplug the refrigerator and then proceed to lightly pry the oval-shaped cover side facing the rear of the refrigerator with your finger nail to remove it. With the LED cover removed you can then press on the LED connector tab to slide it off. Now slide the female connector of the replacement part to the refrigerator male connector and snap the oval-shape plastic cover onto the refrigerator receptacle and then plug it back to its outlet. Now all the lights in the refrigerator should light up brightly! That's all folks. Hope this helps. Good luck. Yours truly.
Parts Used:
-
Elias from PARKER, CO
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
3 of 5 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Replace freezer door handle
Loosen the two set screws. Remove old handle. Install new handle and tighten the two set screws. Job done.
Parts Used:
-
Dennis from NORTH PORT, FL
-
Difficulty Level:Very Easy
-
Total Repair Time:Less than 15 mins
3 of 5 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
freezer stoped freezing
my freezer quit freezing, it would freeze for one day, thaw the next, so I went online, found PARTS SELECT, LOOKED UP MY MODEL #, come to find out it needed three parts to keep my freezer to freeze, first part was a thermistor a small PART took me longer to remove all the covers, and shelving, PULLED THE OLD OUT, CUT THE WIERS TO SIZE, AND REINSTALLED, IT WELL! THAT WASN'T ENOUGH THE FREEZER STILL DIDN'T FREEZE IT THOUT IT WAS A COOL WORMING OVEN, HAD TO INSTALL THE THERMISTOR I, SO I DID, TEN MIN, NOW I THOUGHT THAT WAS IT BECAUSE IT STAYED FROZEN FOR A WEAK, HAVE YOU EVER EATEN SOUPY ICE CREAM? SO BACK TO PARTS SELECT, THIS TIME I BOUGHT ONE MORE PT, THE RUN CAPACITOR, FIVE MIN, THAT/S ALL IT TOOK TO INSTALL. I DID NOT KNOW AT THE TIME YOU NEED THE THREE OF THEM TO RUN THE FREEZER ONE TO KEEP THE TEMP., ONE TO KEEP THE FAN RUNNING THE WAY IT SHOULD, AND THE THIRD TO MAKE SURE THE OTHER TWO KEEP RUNNING. NOW I CAN SET IT AT 4- 5 AND. FREEZE.
Parts Used:
-
paul from ENDICOTT, NY
-
Difficulty Level:Very Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Pliers, Screw drivers
2 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Compressor would run for three seconds and stop, two minutes and repeat.
The overload protector was the problem. It plugs into the side of the compressor and the run capacitor plugs into it.
If you pull the overload protector and it rattles when you shake it, that's probably your diagnosis.
The replacement is different from the original and the wire connectors are different. Hold the thing in the same orientation as if it were plugged in. The vertical connector goes to the neutral wire, which on my fridge is orange. The horizontal connector is for the overload, which for mine is black and white. If you have a schematic you should verify the wires yourself.
Anyway, the refrigerator now works like new.
If you pull the overload protector and it rattles when you shake it, that's probably your diagnosis.
The replacement is different from the original and the wire connectors are different. Hold the thing in the same orientation as if it were plugged in. The vertical connector goes to the neutral wire, which on my fridge is orange. The horizontal connector is for the overload, which for mine is black and white. If you have a schematic you should verify the wires yourself.
Anyway, the refrigerator now works like new.
Parts Used:
-
Steve from SPRINGFIELD, SC
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Nutdriver
2 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
both freezer and refigerator were warm.
I watched the video online and it said there were three sensors in the refrigerator, two in the freezer and one in the refrigerator. I only ordered one sensor and was going to try the one in the refrigerator first. He said the upper one in the freezer is the most difficult, but is usually the problem. So, I replaced the upper sensor and tried restarting the unit. Everything went well and it fixed the problem.
Parts Used:
-
Harry from DURYEA, PA
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver
2 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The Refridgerator and Freezer were not cooling.
-
Frank from VERO BEACH, FL
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Pliers, Screw drivers
2 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator not defrosting, ice tray clogging up in ice tray, refrigerator making loud humming noise, and compressed running all the time.
First, turn off power - since I did not want to pull the refrigerator out on my wood floor I tripped the circuit breaker to that circuit and opened door to make sure interior light was off (ensuring power was off). This unit has a bottom freezer, I took out all shelves, ice maker and all parts in the way of accessing back of interior of freezer section. Removed back plastic section by removing one screw in middle top of back panel and prying it out. This was a bit difficult as it was in there a bit tight but once the plastic warmed up it pulled out ok. This revealed the compressor section and temp sensor that was attached to the copper coils with of all things - a zip tie! In pictures of this that I looked at on various web sites the sensor was on a metal bracket attached to the coil so it made me wonder if tf the factory took a shortcut? I cut the old sensor wire, stripped the two wires 1/2", and connected them to the new sensor wire with butt connectors, I put some silicone into the ends of the butt connectors to prevent moisture from entering into connectors and wrapped the connection in black electrical tape. I then "attached" the sensor to the coil using a zip tie, put the plastic back piece back on, inserted everything I took out and put power back to refrigerator. It's been 3 days and temp of refrigerator is stable, ice maker not clogging up, and compressor not running all the time! So far so good.
Parts Used:
-
Mark from ROSEMOUNT, MN
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:30 - 60 mins
-
Tools:Screw drivers
2 of 3 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
COVER LATCH BROKEN
I recieved the package with the correct part number but the wrong part inside. The item in the package does not even resemble the part on the GE parts website. Tried to contact parts select but no luck.
Parts Used:
-
Steven from NORMAN, OK
-
Difficulty Level:Really Easy
-
Total Repair Time:30 - 60 mins
2 of 3 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Replaced thermistor 5.2 ohms of resistance
Exposed evap defrosted with heat gun exposed defrost element defrost termination switch ok therminster didn’t check out the thermistor sends the signal to logic panel then run the the freezer ice machine and refer temps it took 24 hours before the system starting to show results freezer compartment 10 below ice compartment 0 degrees refer temp 37 degrees one refrigerant three different temps system is running at optimum performance 450.00 $ service call the thing with GE appliances there is no wiring diagram .thankyou parts select .ill use you on all domestic service calls.
Parts Used:
-
elissa from ASHBY, MA
-
Difficulty Level:Very Easy
-
Total Repair Time:More than 2 hours
2 of 4 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!