Dryer would not heat.
Diagnose that the circuit is functioning up to the igniter. This is done by removing the peep hole cover on the bottom front panel, turn the dryer on and watch for a glowing igniter. My dryer would still ignite the first time because the coils would not show an "open" until they heated up. So if you see the igniter glow it is most likely your coils are bad. Remove two screws from lint trap area on top of dryer. Pry up on top panel at the two clips. Panel is on hinges, so flip it out of the way or just brace it with something enough to keep it off the front panel. Remove the two bolts from inside top corners of the front panel. Use a small punch or screw driver to push in on the tab to release the doors electrical connector. Pull straight up on front panel to remove it from bottom clips. The gas valve is very easy to get to without removing the drum. If needed for inspection or cleaning, just pull back on the belt tensioner to remove the belt from the motor and then pull the drum out. Or just use a stubby phillips screw driver to remove the bracket from the top of the ignition coils. Use a very small flat head screw driver to lift the locking tab on each electrical connector while removing. Remove the coils and place new ones in very same position (note the tab or key way of the coils faces up and are defined in the bracket). Re-assemble all parts making sure connections are tight and drum is correctly mounted. Note: if you remove the drum, return the belt back, in a loop, through the tensioner. This part hurt my head for a moment because I did not pay attention. Also a good idea to vacuum the debris and lint while your in there! As always check to make sure the exhaust pipe is clear. Have fun!
Parts Used:
M Series New Style Coil Kit
  • Melissa from FOWLER, OH
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers, Socket set
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
My gas dryer was drying intermittantly. The gas valve wasn't opening when the igniter was firing up.
rts came quickly & I got started. First, I unplugged the dryer and pulled it away from the wall about a foot. this was done so the top would have clearance when it was lifted up. Next, I removed the lint trap and then took the two screws under the lint trap door out. Then you use a screwdriver(flat blade) to release the top of the dryer. The release points are about 1-2 inches from the edge of dryer. Next pull the wire connector apart so the front can be removed. The connector is on the right side, front corner, facing the dryer. There are two hexhead screws near the top on both sides. Remove the and the front will come apart as you lift it slightly. Then you disengage the tub belt. Once this is done the tub can be lifted out and set aside/ take care to remember each things position as you take it apart, so you will not get confused when you reassemble. Now the solinoid assembley is easy to get to. Use a phillips screw driver and remove the two screws that retain the bracket that holds the solinoids in place.. Lift the bracket and remove one solinoid at a time. Pull the wire from it and plug the new, like solinoid to the wire and put it back in place. then do the other one. set the bracket back over the new kit and replace the screws to the bracket. Set the tub back in, rethread the belt to the drive wheel. Next put the front back on making sure the bottom part slips into the two sides of the dryer.Replace the hexhead screws on each side; plug the wire connector together. Now , pull the lid down into position and press into place. Replace the lint trap screws and replace the lint trap. Plug dryer up and we are done. Repossition the dryer to its original place. It really was not a hard job at all. Thank-you Susan for your help and expertise.
Parts Used:
M Series New Style Coil Kit
  • Alfred from DELMAR, DE
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers, Socket set
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The heat would go off after a few minutes
Removed the screws on the dryer vent and the back of the dryer top. Then I raised up the top panel and removed the screws that held the front panel on. I removed the front panel to access the coils. I replaced the coils and then the front and top panel and screws. All went well. The dryer is working properly now.
Parts Used:
M Series New Style Coil Kit
  • John from MUSKOGEE, OK
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers, Wrench set
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
would not heat
I started by changing the part that had the highest percentage to solve this problem , the top three didn't work , the fourth part, the disposable thermostat, and the last one that could be done from the front worked.
Parts Used:
Dryer Radiant Flame Sensor
  • Arthur from VALLEJO, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Socket set
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
the coils was not releasing the gas into the chamber.
I unplug the electric, close the gas valve, use the putty blade to prize up the top,unplug the electric horness, took the front door off, took the anker plate off the two coils, removed the wire from each coil,be careful not toget the wires mixed up one coil has two proms and the other has three proms after that u put everything back together the way u took it off!!
Parts Used:
M Series New Style Coil Kit
  • Frank from EWING, NJ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Pliers, Screw drivers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Drum did not turn on heavy loads, only light loads.
I guessed that a new belt may fix the problem. The repair was nearly as easy as the video suggested. I believe the dryer had been repaired before since there was a circular panel on the side which had been removed. I could reach in through the side to slip the new belt onto the pulley. The new belt now enables the drum to turn even for heavy loads.
Parts Used:
Multi Rib Belt
  • William from MELBOURNE, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
I changed multiple parts on my dryer.
I totally disassembled the Dryer, and replaced the Guide Rollers, Blower Wheel, Idler Pulley Shaft, Idler Pulley, and Belt.
Parts Used:
Blower Wheel
  • Edward A. from PHILADELPHIA, PA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Screw drivers, Wrench (Adjustable)
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Delaminated blower fan
I followed the online video on PartSelect website. No other instruction necessary.
Parts Used:
Blower Wheel
  • Geoffrey from GREAT FALLS, VA
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Socket set
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
dryer door would not stay closed.
I unscrewed the door catch and pried out with some resistance the strike part. Screwed in the catch and pushed in the strike. Closed door. Voila!! Back in business with assurance.
Parts Used:
Dryer Door Catch Kit
  • maria from ROCHESTER, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The door switch was defected
The door switch was easy to replace. It is located in the right bottom of the door and I popped out with my fingers. Follow the wire connectors from the old switch and remounted back in.
Parts Used:
Door Switch Kit
  • Pete from ANAHEIM, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Dryer flame would light then would not ignite again
I used a socket to take of the front cover. I used a screwdriver to remove the two screws that held the coils in place. Replaced the coils and put everything backs together. Piece of cake!
Parts Used:
M Series New Style Coil Kit
  • Susan from Glendale, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers, Socket set
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Loud screeching from idler pulley
The round exhaust duct in the back my dryer can be removed simply by pulling straight out. This gives full access to the belt tension wheel. Slip belt off the wheel, remove snap ring with snap ring pliers, remove washer and wheel. Install new wheel, attach belt, and reinstall duct by looking right down the middle to line up properly. Dryer sounds like new again. 10 minute job.
Parts Used:
Idler Pulley Wheel w/ Bearing
  • Ken from POMPTON LAKES, NJ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
THe burner on the dryer would not light although the glow plug was working
First I shut off the gas supply (the valve is an in-line shut-off and it's right there. I removed both of the retaining screws and detached the gas supply line.

Remove hte valve from the mounting plate (two more screws) and then reversed the process to replace the part.

It works just fine, thank you very much!!
Parts Used:
ASSEMBLY GAS VALVE-120/60 PKG
  • Geoffrey from Centerburg, OH
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Wrench (Adjustable), Wrench set
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broken prong
I began by removing the two screws at the lower part of the front panel. After removing the panel I was able to access and remove the broken switch which was located on the front panel. I popped out the old switch and replaced it with the new one, reattached the wires and put the front panel on and the jod was done.
Parts Used:
Door Switch Kit
  • Larry from Amarillo, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Gas dryer would not ignite.
I removed two wires from the coil valves. Then I removed two screws from the bracket that holds the coil valves in place. I removed the faulty coil valves and replaced them with the new ones. Put the bracket back on and replaced the two screws and wires. It took almost 5 minutes. The dryer is like new once again.
Parts Used:
M Series New Style Coil Kit
  • William from Plainfield, IN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!