Freezer And Frig Both Warm And Compressor Would Not Run
I replaced the thermostat, temperature sensor, and the run capacitor. . . Refrigerator still not cooling. I checked the start relay and measured the input terminals on the compressor for the correct resistance. . . Everything measured correctly. In a last ditch effort before calling for service, I pulled the main board, inspected it and saw the problem right away. One leg on the compression capacitor had desoldered itself. Got out my soldering iron and applied a good amount of solder to that point. Put everything back together and turn it on. . . Problem fixed. The compressor kicked on right away and started cooling the refrigerator.
Parts Used:
Run Capacitor
  • joe from decatur, GA