The control board generated clicking noise. Temperature display wrong values.
On the internet forum I read that if the control board needs to be changed , do the same for the Run Capacitor/relay.
The Ge profile refrigerator was 15 years old. First I disconnect the power cord,
I removed the control board at the back of the fridge, replaced it with a new one and did the same for the run capacitor.
Plugged the power cord back and it works fine. GE repair service did not want to come to do it. DIY is fine.
Parts Used:
Run Capacitor
  • QUOC-LOC from LYNN HAVEN, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Short in the light socket.
Un Plugged the frig. Unlocked the socket by pressing down on the latch. Pulled the socket out ensuring I had enough slack. Unplugged the old socket installed the new. Plugged the frig back in. Tested the switch . Very easy-to-use.
Parts Used:
Light Socket
  • ED from ENON, OH
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Change bulb
Easy
Parts Used:
Light Bulb - 40W
  • Louis from LEAGUE CITY, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
3 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Light burnt out.
Turned the wire protector to the side. Turned out the old bulb and replaced it with the new. Turned the wire protector back in place and I'm like new.
Parts Used:
Light Bulb - 40W
  • Roscoe G from ROCHESTER, NY
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
2 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
socket had melted
pluged the wire harness into the new socket from the back and snaped the socket in place.
Parts Used:
Light Socket
  • Chris from Charlotte, NC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
1 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Light socket missing in refrigerator
Frig parts had been scavenged in an apartment complex. Restoring socket was only a matter of plugging in two spade contacts and clipping in socket.
Parts Used:
Light Socket
  • Wayne from Issaquah, WA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
1 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
compressor running and hot, refer and fridge room temp.
Watched a youtube on capacitors- though on a motor with a pulley, the symptoms were the same, motor running and pulley not turning-bad capacitor. Took a chance for a 17+ dollar part vs a new compressor. It worked.
Parts Used:
Run Capacitor
  • Charles from Durham, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
Was this instruction helpful to you?
Thank you for voting!
light would not stay on
First I flipped breaker to off position for refigerator, Pulled down on socket and broke it free. Then took needle nose piars to pull wire and plug out from hole, so I could conect to new light socket then snaped it in place . Hardest part was getting wire and plug out of hole.
Parts Used:
Light Socket
  • Kenneth from Leavenworth, KS
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
Was this instruction helpful to you?
Thank you for voting!
needed new light socket
Pulled out old socket.pushed in new one.
Parts Used:
Light Socket
  • Charles from Williamsburg, VA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
Was this instruction helpful to you?
Thank you for voting!
Both the fridge aqnd freezer would not get cold.
Easy. Followed the video instrucations. the part was right there next to the compressor.
Parts Used:
Run Capacitor
  • Mary from Farmingdale, NY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
fan and compressor wont start
Googled the model number of refrigerator with symptoms of "refrigerator wont run". Parts select web site appeared on my screen, opened Parts Select website, Partselect said probable cause of my frige symptom was that the run capacitor usually burns out 51% of the time. They were correct with the diagnosis 100%. I ordered the run capacitor for $23.00, installed it in 10 minutes, refrigerator runs good as new. Thank you for saving me cost of service call. I probably saved $200 or more. I will use Partselect again with my next problem. THANK YOU,
Parts Used:
Run Capacitor
  • JOSE from NEW YORK, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Refrigerator and freezer drawer would not maintain set temperature
Condenser fan motor was running slow. This was not a problem included in your list of possible problems. I thought that maybe the capacitor was bad but have no way to check it. So I ordered one. when I received it, I installed it. That was not the problem. So I ordered a fan motor and installed it. That was not the problem. So finally I ordered a control board and installed it. That solved the problem. So maybe you should put "cond.fan motor runs slow" in your list of possible faults and what causes that problem. Capacitor was easy to install, simply remove the cover plate, flip off retaining wire, unplug the capacitor and replace. Fan motor was a bit more difficult. It must be removed from mount after fan scroll is removed. Remove one screw that holds scroll, bend the top down and remove. Then pull hard on fan blade to remove it. It must be installed on new motor. Two screws in frame mount can be removed with some effort if you have a 1/4" drive ratchet with a Phillips screwdriver bit. Then pull frame open and install new motor. Push fan blade on new motor shaft hard. Replacing control board was easy. I used a pair of long nose pliers with 90 degree bend to get mounting pins closed to pull board off.
Parts Used:
Run Capacitor
  • James from Bel Air, MD
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Socket set
Was this instruction helpful to you?
Thank you for voting!
The motor was making a thumping out of balance sound.
Naturally you have to push the frig from the wall and unplug it form the wall outlet and while you are removing and installing the old motor and installing the new motor. Do not open any of the frig and freezer door untill you are finished and you plug the power cord back into the wall outlet. Remove the lower back panel with a screw driver or a 5/16th hex driver. It is a kind of carboard. Once all the screws are out of that panel pull the top out from behind the steel above and then pull it out from the bottom and set it aside. Unplug the power line off of the motor. There are 3 separate brakets holding the motor in place. 1st remove the fan from the motor by romving the finger nut off the motor shaft and then remove the 1st bracket screw from the bracket all the way. Then use a light to see the other 2 screws and you will see that you do not have to take them all the way out like the first one. Just loosen the other 2 and then turn the motor and brackets counter clockwise and then pull the motor and brackets all out as one from the right hand side of where the brackets were mounted. I took the motor and brackets to the counter and removed te brackets from the motor and installed them to the new motor making sure that the bracket with the one screw hole in it is mounted at the right place so that when you reenstall the motor and brackets will let the motor wire connector be the closest to the outside where you can replug the power cord back onto the motor. Install the fan onto the new motor with the new finger nut that comes with the new motor. replace the back panel and pkug in the power cord fot the frig and let it run. Mine ran a lot quieter after the new motor was plugged in. Have fun if you have to do it. It is worth it.
Parts Used:
Condenser Fan Motor
  • Alan from Spring Valley, IL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Socket set, Wrench (Adjustable)
Was this instruction helpful to you?
Thank you for voting!
Starter/overload assembly and run capacitor were bad
Removed rer cover, unplugged starter assembly from side of compressor and replaced unit with a new one. Plugged fridge in and it works good.
Parts Used:
Run Capacitor
  • Colby from Blanding, UT
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Compressor fan bearing worn. Refrigerator was manufactured 9/78/
I followed the instructions verbatim as others explained. I did it step by step exactly as instructed, The timing was almost exact no more than 30 minutes. I removed the fan the night before the delivery of the new fan and used a small desk fan to cool the compressor. It worked fine in one half hour my freezer read a perfect zero. Thanks for all the help
Parts Used:
Condenser Fan Motor
  • Edmund from Bethel Park, PA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Socket set
Was this instruction helpful to you?
Thank you for voting!