Frost in freezer, fridge not cold
From most posts I've read, the defrost timer was the culprit so I blindly ordered one. Easy install but did not fix the problem so I broke out the ohm meter. The only other 2 items it could be all tested good with my meter so I bypassed the defrost thermostat (per forum help...actually quite easy)and it defrosted fine, which told me I needed a new defrost thermostat. Installed fairly easy and problem gone.
Parts Used:
Defrost Timer - 60Hz 120V
  • Bob from Pinole, CA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
all 3 refrigerator door retainer bar were broken
I had to cut the replacement bars to the correct length. But everything else was easy. The quality of the repacement bars is much better than the originals. Thanks!
Parts Used:
Door Shelf Retainer Bar - Cut to Fit Door Shelf Retainer Bar End Cap - Right Side Door Shelf Retainer Bar End Cap - Left Side
  • cheryl from hammond, NY
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The refrigerator wasn't getting cold the freezer was getting to cold
Followed the installation instruction for both parts now both the freezer and refrigerator are getting cold
Parts Used:
Defrost Thermostat Defrost Timer - 60Hz 120V
  • eddie from CHICAGO, IL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Socket set
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
the freezer would stick in defrost and not come out
Removed the vent cover at the bottom. Removed the screws. disconected the harnes and put the new timer in. This was a very easy fix. Thank You!
Parts Used:
Defrost Timer - 60Hz 120V
  • carol from woodland, WA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
relaced shelves
Removed old , assembled and popped in new.Perfect!
Parts Used:
Door Shelf Retainer Bar End Cap - Right Side Door Shelf Retainer Bar End Cap - Left Side
  • Christine from Bourne, MA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Defrost timer was not working
Found the part on this site ordered and received part in 3 days. Took approx. 10 min to replace. Thanks for the quick service.
Parts Used:
Defrost Timer - 60Hz 120V
  • Harold from Grants, NM
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
2 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
I was missing the bar and end caps for the bottom shelf
I purchased a left and right end cap and the bar but I ended up with 2 right end caps of different sizes. Partselect happily accepted my return and shipped the correct part. I hadn't had a bottom condiment shelf for over 4 years. It's nice to have one now. It was easy. Just popped on one end cap, slid the bar on, slid on the other end cap (had to force a little) and popped on that end cap. Voila! new shelf.
Parts Used:
Door Shelf Retainer Bar End Cap - Left Side
  • Deborah from Warren, MI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broken shelf retainer end
I just slid the end of the cap on the end. REAL EASY...Now I can use my shelf again.
Parts Used:
Door Shelf Retainer Bar End Cap - Right Side
  • Francine from Port Charlotte, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The end cap for the lower door shelf broke
Removed the broken end cap piece from the shelf retainer bar. You need to pry up the little metal tabs with a screwdriver to remove the end cap, then slide in the new one and crimp down the tabs with the pliers. super easy. Replacement part was identical so it fit perfectly.
Parts Used:
Door Shelf Retainer Bar End Cap - Left Side
  • James from Austin, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator wasn't getting cold
removed the back panel of the freezer and unplugged the connector for the Motor. Removed the air diffuser, then removed the fan blade. Removed the 2 screws holding the motor to the bracket. Disconnected the old wire harness and installed the new one. Put the fan blade onto the new motor and installed the motor onto the bracket. Put the air diffuser back on, plugged the motor back in and fastened the back panel. Plugged the refrigerator into the outlet and tested, OK!
Parts Used:
Evaporator Fan Motor Kit - 120V 60Hz
  • Brad from STOCKTON, CA
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer worked, refrigerator didn't. Ice build up on coils.
Unplugged refrigerator. Emptied freezer and removed ice maker and cover, need to unplug fan. Defrosted coils with hot water. Cut wires to thermostat as close to it ad possible to leave extra wire in case of an error. Stripped wire in new thermostat and put in shrink plastic then the wire crimp connector joining both light blue wires making sure wires were in before crimping them. Repeated with other dark blue wire. After used the heat gun to shrink the protective white tubing. The only thing i found not satisfying was tge tubing. It was too wide and too small. When i shrunk it did not cover the whole connector and was loose. I had to use a glue gun to cover both ends of each wire connector. Hope this helps other users.
Parts Used:
Defrost Thermostat
  • Salvador from SANTA ANA, CA
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
door shelves were broken from use
simply replaced the pieces directly. It was very easy.
The different parts are easily deciphered and reassembled.
Parts Used:
6A- Door Shelf Retainer Bar End Cap - Left Side Door Shelf Retainer Bar - Cut to Fit Door Shelf Retainer Bar End Cap - Right Side Door Shelf Retainer Bar End Cap - Left Side
  • Murray from FORT MYERS, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Light not turning on when door opened
Used a flat head screwdriver to pop out the old switch, removed the contacts and placed on the new switch, popped the switch back in. Done in about 2 minutes.
Parts Used:
Light Switch
  • Michael from TUCSON, AZ
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Intermittent loud noise coming from fan motor located in freezer compartment
Ordered a new evaporator fan motor and watched the repair video supplied by part select on their web site.It was spot on step by step instructions
Parts Used:
Evaporator Fan Motor Kit - 120V 60Hz
  • Donald from Okeechobee, FL
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Coils frozen over. Refrigerator not cooling
I cut wires from bad thermostat and removed it . Stripped wires and crimped connectors on new thermostat and wires from old thermostat. Used heat gun to seal sleeves over connectors. Very helpful video from this site Thanks, you will be my go to parts supplier from now on!!!!!!!!!!!!
Parts Used:
Defrost Thermostat
  • Robert from MONTGOMERY, IL
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Socket set
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!