No or little ice would dispense
Went exactly by the video. Perfect job, you send the installation video with the part. You watch the video before or during, goof proof, took longer to disassemble than to replace the part.
Parts Used:
-
stephen from GOODLETTSVLLE, TN
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Nutdriver, Screw drivers
2 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Won't dispence ice or water
Changing out solenoid was very easy, but you don't have to remove trim ring and it didn't fix my problem. Turns out a relay fell out of its holder in the piece you have after removing the 4 screws per the video.
Parts Used:
-
Randy from Cypress, TX
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Screw drivers
2 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Frozen water dispenser line; install water line heater
This should have been easy, but I couldn't get the housing shield off. I removed the 4 screws but it wouldn't come off. It seemed to be stuck in the lower right. (It seems that many people have the same problem.) I decided to destroy the old one and install a new dispenser housing shield, and replace the flapper while I was at it. I finally got the shield off (by taking a pipe wrench to it and breaking it into little pieces) and discovered what the problem was: the light in the lower right had melted the plastic of the dispenser shield, which fused to the plastic of the housing! Bad design, GE! After that, it was no problem. However, I couldn't remember how to replace the microswitch. I should have taken a picture, first. Duh. Lucky for me, Parts Select had a very informative video showing how to replace the microswitch. ! was saved! Thanks, Part Select!
Parts Used:
-
Harvey from ATLANTIS, FL
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:1- 2 hours
-
Tools:Pliers, Screw drivers
2 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
noisy evaporator fan motor
Replaced evaporator fan motor, and this solved the whistling noise that had developed. Reviewed and followed the removal and installation instruction video as closely as possible. This was very helpful, with a few additions. For the model PS123NGPBBB GE refrigerator/freezer, there were a few differences from the video. There a was an additional cover panel that was positioned vertically at the back of the freezer compartment below the auger motor assembly. It was necessary to remove this cover (4 screws) to gain access to the auger motor cover screws. The unit also has a different light configuration with 2 lights. I found it helpful to remove these light bulbs and the corresponding light fixtures in order to remove the evaporator motor assembly. As mentioned in the video, it was necessary to cut the 4 wires from the wire harness of the new motor, and use butt end connectors to reattach these wires to the corresponding wires in the unit. Total job took between 1 and 2 hours, and the motor change solved the noise problem.
Parts Used:
-
Russell from GLEN, NH
-
Difficulty Level:Easy
-
Total Repair Time:1- 2 hours
-
Tools:Screw drivers, Socket set, Wrench set
2 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The capacitor on the main board was shorted and swollen
This particular model has the top mounted compressor so the main board was located in the top section behind a metal shield. Remove all the plugs from the board they are all different sizes so it’s easy to replace correctly. The most difficult part is removing the board from the nylon stand offs. Use needle nose pliers to press retainers in and pull each corner from the standoff. A piece of 1/8 metal tubing makes compressing the standoffs easy.
Parts Used:
-
THOMAS from LOGANVILLE, GA
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver, Pliers, Screw drivers
2 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice funnel was broken and didn’t dispense water or ice
Used a YouTube video with step by step directions, this made the repair very easy.
Parts Used:
-
Jennifer from EDMOND, OK
-
Difficulty Level:Really Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Pliers, Screw drivers
2 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Solenoid wasnt pumping water to the ice maker
I started by shutting off the water inlet valve and then unplugged the refrgerator. I then disconnected the tubing leading into the solnoid. Removed the old solenoid, replaced it with the new part reconnectted the tubing and gave it a test run. After about 2 hours we had ice being made again! I then reconnected the bracket to the refrigerator and haven't had a problem since.
Parts Used:
-
Michael from Boyds, MD
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Screw drivers
3 of 5 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
heavy frost buildup in ice dispenser chute and door
After inspection of the new door recess assembly, I realized that I could use sidecutters (electronic assembly type) and 'clip' off the inward lock tabs of the old recess assembly and disengage it from the crank door arm without any further disassembly of the refrigerator door. It was easy to 'unhitch' the tang from the crank arm and wiggle it out through the external opening of the ice/water dispenser compartment. I reversed the process and inserted the new assembly through the external opening of the compartment. The new door recess assembly snapped into place on the crank arm and fit tightly against the ice chute opening, correcting the issue caused by aging distortion of the old rubber seal cup portion of the door recess assembly.
Parts Used:
-
Robert from Rockford, IL
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Pliers
2 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker
Remove ice maker out of fridge; remove 3 screws
replace defective part re-install all components 30 minutes later " magic ice again. Very easy repair most important low cost. Thanks "Parts Select"
replace defective part re-install all components 30 minutes later " magic ice again. Very easy repair most important low cost. Thanks "Parts Select"
Parts Used:
-
Eli from Buford, GA
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers
2 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water leaking and freezing everywhere. Weird shaped ice cubes, more like chunks which jambed the dispenser.
First removed the two screws that holds the old ice maker in place. Unplugged it. The freezer compartment was too narrow to allow the unit to slide out or turn in any other direction. Had to also remove the two front screws from the left side ice bin track and swing it down. The door opening was also too tight. Scratched the plastic door jamb putting the new unit in but other than that all is well and functioning well.
Parts Used:
-
Peter from Riverdale, NJ
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver
3 of 5 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
the cecular door for the ice was geting stuck opened
with a small screwdriver push in tabs in upword movement to remove the face cover for the three botons of ice crushed ice and water .
once removed remove four screw to take out the circular door .
solinoid plunger will be atached to the door and it has to screws holding the solinoid .
instolation is the oposit steps of removing the part
once removed remove four screw to take out the circular door .
solinoid plunger will be atached to the door and it has to screws holding the solinoid .
instolation is the oposit steps of removing the part
Parts Used:
-
john from st aug, FL
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Socket set
2 of 3 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice dispensor door would not open all the way and did not close
I used a mirror to locate the two small plastic tabs located on the underside of the ice dispenser light. I used a small flat blade screwdirver to push the plastic tabs forward to release the ice/water selector unit. I read about someone that did not see the tabs and ended up removing the inside of the freezer door, a two hour task! The ice and water control unit then slides out. remove the four rusty screws holding the dispensert and ice chute, the selenoid isthen easy to see.
Just replace the solenoid if your are having problems, I tried to lube it but to now avail. There is some rust in there so good time to clean up and put new screws in. Be care when removing the plastic lock tab on the circut board it breaks easely. If it does no big deal just make sure the connection is pushed in all the way. test your handy work before buttoning up. The solenoid comes with a new plunger so don't worry about cleaning the old one. The screws do not come with.
Just replace the solenoid if your are having problems, I tried to lube it but to now avail. There is some rust in there so good time to clean up and put new screws in. Be care when removing the plastic lock tab on the circut board it breaks easely. If it does no big deal just make sure the connection is pushed in all the way. test your handy work before buttoning up. The solenoid comes with a new plunger so don't worry about cleaning the old one. The screws do not come with.
Parts Used:
-
Richard from Coppell, TX
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers
2 of 3 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Defroster fan burned up
First I removed the ice tray rack lifting it out of the way to reach the back cover of the fan. Then, the whole back inside panel had to be removed. Two screws removed the fan and bracket from the freezer unit. The missing bumper lid just snapped into place. Replaced everything in reverse order. Pretty easy job.
Parts Used:
-
Peter M. from Lincoln Park, NJ
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver, Pliers, Screw drivers, Socket set
3 of 6 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
frost/ice buildup in icemaker chute in the freezer door
The only difficult part was not knowing which parts had to be removed to gain access to the flapper to replace it. It appeared as if the frame around the control panel would have to be removed as well as the door handle; we tried but were not able to remove the frame. It turned out that the panel just popped out with the frame in place. Once we had access to the flapper, it was easy to replace it. The repair fixed the problem.
Parts Used:
-
Kyoko from Bellevue, WA
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Screw drivers
2 of 3 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator not defrosting, ice tray clogging up in ice tray, refrigerator making loud humming noise, and compressed running all the time.
First, turn off power - since I did not want to pull the refrigerator out on my wood floor I tripped the circuit breaker to that circuit and opened door to make sure interior light was off (ensuring power was off). This unit has a bottom freezer, I took out all shelves, ice maker and all parts in the way of accessing back of interior of freezer section. Removed back plastic section by removing one screw in middle top of back panel and prying it out. This was a bit difficult as it was in there a bit tight but once the plastic warmed up it pulled out ok. This revealed the compressor section and temp sensor that was attached to the copper coils with of all things - a zip tie! In pictures of this that I looked at on various web sites the sensor was on a metal bracket attached to the coil so it made me wonder if tf the factory took a shortcut? I cut the old sensor wire, stripped the two wires 1/2", and connected them to the new sensor wire with butt connectors, I put some silicone into the ends of the butt connectors to prevent moisture from entering into connectors and wrapped the connection in black electrical tape. I then "attached" the sensor to the coil using a zip tie, put the plastic back piece back on, inserted everything I took out and put power back to refrigerator. It's been 3 days and temp of refrigerator is stable, ice maker not clogging up, and compressor not running all the time! So far so good.
Parts Used:
-
Mark from ROSEMOUNT, MN
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:30 - 60 mins
-
Tools:Screw drivers
2 of 3 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!