Ice cutting grid wire broke into.
Removed broke wire and replaced new wire. Use gloves to pull the wire tight. That's very important.
Parts Used:
-
William from WINTER HAVEN, FL
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
broken light switch
Figured out You have to pop off the cocer than remove the 1/4 hex head screws only not the philips ones
Parts Used:
-
Atlee from Jupiter, FL
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver, Screw drivers
0 of 1 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Failure to make ice
Unit was failing to make ice as a result of cutting grid fail (broken cutting wire disrupted circuit so no heating) and corresponding ice build up on cooling plate. Defective cutting grid swapped out - replacement part had superior design to OEM and was made of comparable to superior materials. Very satisfied.
Parts Used:
-
James from Baltimore, MD
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver
0 of 3 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
our ice maker was not cutting the ice into squares.
I determined it was the cutter grid because there was a broken wire on the existing one. They have to heat up and cut the ice. I ordered it and the part was at my house in 1 day. The cutter grid part was easy to install. The ice maker is working great now.
Parts Used:
-
Scott from Phoenix, AZ
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver
Was this instruction helpful to you?
Thank you for voting!
loud noise coming from back of fridg.
Unplug A C Cord . Simply unscrewed lower back cardboard cover panel and unscrewed condenser fan motor , removed wiring plug , pulled fan motor out removed fan blade and put it on new motor . then I Reinstalled motor. Noise is gone . EASY INSTALLATION .
Parts Used:
-
William from Fort Mohave, AZ
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver
Was this instruction helpful to you?
Thank you for voting!
Unit very noisy when running sometimes and then get quiet the noise would vary
Remove back panel on unit locate condenser fan and motor remove three small screws holding motor assembly to metal bracket disconnect electrical connection press new fan blade on new motor reverse directions
Parts Used:
-
william from glen gardner, NJ
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Socket set, Wrench set
Was this instruction helpful to you?
Thank you for voting!
Loud fan motor
Removed lower plate on back of refridgerator and changed out fan. The video was great and made the repair a snap. Fan is quiet and no more overheating refridgerator.
Parts Used:
-
Brian from Saint Augustine, FL
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver
Was this instruction helpful to you?
Thank you for voting!
Recent move and movers broke the light switch on refrigerator side.
Unplugged the refrigerator then removed two vertical screws on the very back back of the control panel (the ones with the washers). Do not remove the four other vertical screws in the panel. The front plastic plate on control panel snaps off and there are two horizontal screws under the plate. Remove them and the control panel will drop down allowing access to the light switch. Unplug the two wires (one black and one white) from the old switch. Discard the old switch, snap the new one into place and reconnect the two wires. Snap the front plastic plate back into place, plug in the refrigerator and you are done! Problem solved with a new $16.00 switch and saved at least $75.00 or more from an appliance repair call. Thanks Part Select!
Parts Used:
-
Carl from Warsaw, MO
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers
Was this instruction helpful to you?
Thank you for voting!
condenser fan motor making alot of noise, possibly going out.
A bit of a tight squeeze for my hands, but very basic as I followed the instructions and watched the installation video. I only had the fridge unplugged for about 20 min..The fridge is as quiet, as it was brand new. The only tool I needed was the 1/4 inch socket wrench. A portable lantern was very helpful as well. Runs very quiet now, like new! Thx!!!
Parts Used:
-
rex from folsom, CA
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Socket set
Was this instruction helpful to you?
Thank you for voting!
Compressor fan and motor was load,barring was wobbling .
-
William from Fox lake, IL
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver, Pliers, Socket set
Was this instruction helpful to you?
Thank you for voting!
No water running across the evaporate plate
Since no ice was forming on the evaporator plate, I first checked to see if I was getting water. Water to reservoir was fine, but it was not moving from the reservoir. Pretty logical that something was wrong with the pump. I pulled pump out. It was locked up, with a significant amount of calcium buildup. Replaced it and all works fine. Great ice again.
Parts Used:
-
Scott from Las Vegas, NV
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver, Pliers
Was this instruction helpful to you?
Thank you for voting!
Loud condenser fan
Pretty much followed the how to video. Biggest pain was removing the screws to the bracket that houses the motor.
Parts Used:
-
Mike from Lake tapps, WA
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers, Socket set
Was this instruction helpful to you?
Thank you for voting!
Old fan housing broke
Disconnected power cord, removed rear cover of refrigerator, disconnected pig tail, removed 4 housing screws, took three mount screws out and removed old fan. Reversed steps, plugged in and complete repair done.
Parts Used:
-
Michael from Pinedale, WY
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver, Socket set
Was this instruction helpful to you?
Thank you for voting!
Fan became noisy and started wobbling.
UPS delivered the part at 11:05 AM and I had it installed in less than 30 minutes. No issues, easy removal and re-installation although the compartment was very tight for my hand and a 1/4" drive socket wrench. One installation suggestion however, pre-thread the 3 mounting screw holes on the motor housing first by screwing one of the screws provided into each of the three mounting holes on the motor housing prior to attempting to install the new motor. This way you'll find it much easier to get start the screws given the very limited work-space behind the fan compartment.
Parts Used:
-
James from Cave Creek, AZ
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Socket set
Was this instruction helpful to you?
Thank you for voting!
Water was not circulating onto freezing plate
Simple, remove water reservoir (2 screws). Remove pump cover (1 screw). Remove 2 screws on bracket holding pump and unplug pump. My wiring was somewhat corroded and it took a bit of pulling to unplug. When you replace with new motor make sure to snap in new plug snug or it will not start up. Reassemble and away you go.Making ice no problem.
Parts Used:
-
doug from atlanta, GA
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Pliers, Socket set
Was this instruction helpful to you?
Thank you for voting!