W8TXNGMWB01 Whirlpool Refrigerator - Instructions
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
light inside fridge was flickering and clicking
tested bulb good ,replaced door switch first(least expensive)then ordered light socket and circuitboard.If clicking sound is heard replace circuitboard first to save on return shipping because the switch and socket where ok
Parts Used:
-
bill from escondido, CA
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver
20 of 35 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
evaporator iced up every 5 days or so
Very easy, unscrewed control panel cover (1 screw) which is located under the freezer compartment inside the refrigerator. Took out non working defrost timer installed new one replaced cover, done. Total time: less than 5 minutes.
Parts Used:
-
nicholas from riverside, CA
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Pliers
14 of 18 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The ice maker stopped working
First I unplugged the unit, then I popped off the cover to the icemaker electronics. Removed 4 screws, pulled out the broken electronic panel, and replaced with the new one. Returned the screws and cover. The next moring the ice bin was full.
This must have saved me $300, and the inconvernience of waiting around for the repair man. He would have made two trips since he would never have had this part with him.
This must have saved me $300, and the inconvernience of waiting around for the repair man. He would have made two trips since he would never have had this part with him.
Parts Used:
-
Duncan from Larchmont, NY
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Screw drivers
16 of 25 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Leaking water inlet valve
This would have been a less-than-5-minute repair except for one item. The water intake nossle was 180 degrees from the original part. As a result, the copper water inlet tube would not fit in the old space and still allow me to reattach the valve to the freezer chassie. I ended up leaving the valve hanging loose under the freezer. I spent most of my time trying to fit the valve into the old space.
Unplug freezer. Disconnect electrical connections (pull apart). Remove one screw holding the valve to the chassie. disconnect water inlet pipe and water outlet pipe from old valve.
Reconnect electrical connection to new valve. Reconnect in and out water hoses. Reconnect valve to chassie. Plug freezer back in. Finished
Everything works just fine !
Unplug freezer. Disconnect electrical connections (pull apart). Remove one screw holding the valve to the chassie. disconnect water inlet pipe and water outlet pipe from old valve.
Reconnect electrical connection to new valve. Reconnect in and out water hoses. Reconnect valve to chassie. Plug freezer back in. Finished
Everything works just fine !
Parts Used:
-
Steven S. from Kerrville, TX
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver, Wrench (Adjustable)
14 of 19 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Scratches in Surface
This product comes in a bottle with a brush like Liquid Paper. It goes on incredibly easy. A second coat might be needed. I wanted to prevent rust from setting in so I covered the scratches and dings. The paint is a little brighter since my washer is 10 years old but it still looks great.
Parts Used:
-
Michelle from Richardson, TX
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
83 of 227 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator and freezer was not "working " ,ice machine not working.
Removing the panels inside the freezer section was the most difficult ,because it is narrow,hard to fit your body inside compartment, in order to cut wires and to splice Bi-metal Defrost Thermostat wires (2 ) Watch the videos on the web site so you know where to start. First time I ever "repaired " a large appliance, saved me over $ 600.00 (that's what the people I bought the Refrigerator from wanted to charge me.) My parts cost 65.00 !!!!! My younger brother turned me onto the web site... , I'll be returning to the site and telling my friends about it. It's a total "rip off" what service organizations charge the general public these days from Car Dealer ships to the stores we purchase our appliances from. !!! Glad I still have my health and faculties to repair the essentials we have around our homes. !!!!
Parts Used:
-
Guy from MUNSTER, IN
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Pliers, Screw drivers, Socket set
11 of 12 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
No water to the ice maker
At age 65 I have never attempted to repair a refrigerator, until now. It took longer than needed because I did not read these articles carefully. Please note that when you open the door and the light blinks twice, waits a second and blinks again, the optics are working fine. I ordered an emitter and receiver when I didn't need to. I sent it back, the money was refunded, and ordered the ice maker. I replaced the old icemaker by removing three screws and slipping it out of its holder.
Here is how I found out I needed the new ice maker. I took the supply line apart that runs down the back of the refrigerator. I blew through it without any trouble. This told me that the line was not frozen within the refrigerator. I put the supply line back together, and jumped the solenoid that was connected to the supply line at the bottom right of the refrigerator. My model is the side by side, so it has two solenoids. The solenoid that runs the water to the dispenser in the door was always running, so I knew if there was a problem it would be with the ice maker solenoid. So, how did I jump the solenoid. Kids, don't try this at home. I disconnected the wiring harness to the solenoid by pulling it straight out. Then I took the female end of an extension chord and placed a twelve two electrical wire with the ends stripped into the positive and negative slots. I then jumped the solenoid. Water ran to the ice maker, but there still wasn't any ice made. Since the optics and the solenoid were working it seemed to me that the ice maker wasn't doing it's part. There are easier ways to check the solenoid in this forum, but this worked for me. I saved a lot of money and the parts got here quickly.
Here is how I found out I needed the new ice maker. I took the supply line apart that runs down the back of the refrigerator. I blew through it without any trouble. This told me that the line was not frozen within the refrigerator. I put the supply line back together, and jumped the solenoid that was connected to the supply line at the bottom right of the refrigerator. My model is the side by side, so it has two solenoids. The solenoid that runs the water to the dispenser in the door was always running, so I knew if there was a problem it would be with the ice maker solenoid. So, how did I jump the solenoid. Kids, don't try this at home. I disconnected the wiring harness to the solenoid by pulling it straight out. Then I took the female end of an extension chord and placed a twelve two electrical wire with the ends stripped into the positive and negative slots. I then jumped the solenoid. Water ran to the ice maker, but there still wasn't any ice made. Since the optics and the solenoid were working it seemed to me that the ice maker wasn't doing it's part. There are easier ways to check the solenoid in this forum, but this worked for me. I saved a lot of money and the parts got here quickly.
Parts Used:
-
Ron from Ferndale, WA
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver
11 of 13 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Didn't know if I needed Left or Right.
The item is listed as R, meaning right hand side. If you need it for the left hand side, simple turn it over. It is designed to work on both sides of the door.
Parts Used:
-
Joyce from Kerrville, TX
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
11 of 14 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
socket melted with bulb in it.
-
martin l. from JACKSONVILLE,, IL
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
12 of 18 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Blower motor expired
Pulled off the interior panel, removed the old blower, reinstalled the new one, plugged the frig in to make sure it ran and replaced the interior panel.
Parts Used:
-
Raymond from Cedar Falls, IA
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver, Pliers, Screw drivers
10 of 12 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker stopped working
Our ice maker had been overfilling and causing a big block of ice in the bin for some time, but it finally stopped working completely. In trying to determine the problem, I read the comments on the PartSelect website from other customers and thought I needed either a new valve or a new ice maker. I replaced both because when I took the old ice maker out, it had a lot of mineral deposits in it and looked very unappetizing. The videos on how to replace the valve and ice maker were very helpful. Other customers comments on replacing the valve were also great. The only thing I would add is that after getting the parts installed and the water line and electricity reconnected, it takes an hour or so for the ice maker to to fill. I suppose there is a temperature sensor that won't fill it until gets down to a certain point. I am very pleased with the outcome of this project on our 28 year old refrigerator.
Parts Used:
-
Martin from DESOTO, TX
-
Difficulty Level:Really Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver
9 of 9 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
THERMOSTAT
I followed your instructions , the only thing that was left out was that the freezer has a drain hole that had to be thawed out with a hair dryer,till the water went to the drain pan underneath the ref. your instruction were through enough, that's why I purchased the part from your company, I installed the part 2 days ago and its working like new again 23.00 for the part instead of 1200.00 dollars for another ref. thanks very much. 6 months ago I purchased the relay and compressor starter from your company at that time per your instructions I shook the compressor starter and like a light bulb it had something broke inside,I needed that thanks again oomk
Parts Used:
-
dominique from COMPTON, CA
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver, Screw drivers
9 of 10 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
There was no light on in refrig area
Just replaced the switch, but unfortunately that was not the problem; nor was it the bulb....so I am back to square one.
But Parts Select is a great place to order from. Thank you.
But Parts Select is a great place to order from. Thank you.
Parts Used:
-
Lori from Chuluota, FL
-
Difficulty Level:Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Screw drivers
12 of 19 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Icemaker Would Not Produce Ice
Contacted sears home service to perform repair. Quote for repair was $307. 43. ( $196. 90 For labor ,$102. 58 For part) plus $75. 00 For service call. Based on the charge, I refused the repair and ordered the appropriate part from "part select" (733947) (wpl 8201515) motor module for a cost of $81. 84. To my surprise, the part arrived the next day and in 15 minutes the icemaker was in a position to make ice, and has been producing ice ever since. To perform the module replacement, I had to remove one screw with a nutdriver, pull the icemaker out, disconnect a wire harness, replace the module and do the reverse procedure to complete the installation. I saved a total of $225. 59 By doing this repair myself. A lesson learned. . . . . I will always investigate doing a repair myself with the help from the people at part select. Very professional and they sent the correct part the first time.
Parts Used:
-
ROBERT from INVERNESS, IL
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver
8 of 8 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
replacing thermostat did not help
Icecubes came out half-way, and refrooze. I figured out, that the melter does not work (HEATER in the icemaker) Voltage measured 105V no load. Studied the Internet, and folloved an advice: shorted the back wire and the blackwire with white stripes.these go to relay contacts. It seems, that the relay contacts are no good on Infrared receiver boaed. I turn off manually the icemaker, when needed
Parts Used:
-
John from Rocky River, OH
-
Difficulty Level:Difficult
-
Total Repair Time:More than 2 hours
-
Tools:Pliers, Screw drivers, Socket set
10 of 15 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!