Light would no longer turn on
I watched the video online, followed the instructions and within minutes had the part installed. The frig light was working once again! I will say the original switch was very snug and I had to do some very minor scraping of the plastic to get the new part to slide in.
Parts Used:
-
paypal_shipping_address from Ripon, CA
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Pliers
3 of 6 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice flap in door wouldn't close
Take the face (the part with the buttons on the outside) off, disconnect wired connectors (three), take the screws out of the part behind that (4), and then find the solenoid value (on the right). It's attached with three screws. Mine was rusted beyond belief. I knew this was the problem, ordered a new solenoid valve, put it back in place with three screws (use new screws that fit, not the old rusty ones if possible). When testing, make sure you give the flap a couple of seconds to close. There is a delay, and I initially wasn't patient enough so I had to disassemble and assemble an extra time because of this.
Simply put: If your solenoid value is rusted and the value won't operate smoothly, order the part and install it. This is as easy as any repair could be.
Simply put: If your solenoid value is rusted and the value won't operate smoothly, order the part and install it. This is as easy as any repair could be.
Parts Used:
-
Benjamin from Goldsboro, NC
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Screw drivers
2 of 3 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
water leak from water line and value housing
Unplugged unit. Removed back cover plate. Used 5/16 water line. Cut old broken line. Used water tube union and attached new line. Removed electrical contacts. Note very easy removeand replace the red and white hookups. Next remove water line at the old vale with1/2 wrench. Hook up water line to new valve. Icemaker line was not damaged so I removed from old valve and trimmed the end. Really installed line to valve. Plugged in fridge and turned water supply back on. Check for leaks. Had trouble locatingthe 5/16 water line but found bulk. PARTS SELECT had the guest connector and the replacement valve. I received the correct parts and saved me $$$$. Plus my wife happy right before the holidays! !!,
Parts Used:
-
Joseph from Stewartsville, NJ
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Wrench set
2 of 3 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Defroster fan burned up
First I removed the ice tray rack lifting it out of the way to reach the back cover of the fan. Then, the whole back inside panel had to be removed. Two screws removed the fan and bracket from the freezer unit. The missing bumper lid just snapped into place. Replaced everything in reverse order. Pretty easy job.
Parts Used:
-
Peter M. from Lincoln Park, NJ
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver, Pliers, Screw drivers, Socket set
3 of 6 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice dispensor door would not open all the way and did not close
I used a mirror to locate the two small plastic tabs located on the underside of the ice dispenser light. I used a small flat blade screwdirver to push the plastic tabs forward to release the ice/water selector unit. I read about someone that did not see the tabs and ended up removing the inside of the freezer door, a two hour task! The ice and water control unit then slides out. remove the four rusty screws holding the dispensert and ice chute, the selenoid isthen easy to see.
Just replace the solenoid if your are having problems, I tried to lube it but to now avail. There is some rust in there so good time to clean up and put new screws in. Be care when removing the plastic lock tab on the circut board it breaks easely. If it does no big deal just make sure the connection is pushed in all the way. test your handy work before buttoning up. The solenoid comes with a new plunger so don't worry about cleaning the old one. The screws do not come with.
Just replace the solenoid if your are having problems, I tried to lube it but to now avail. There is some rust in there so good time to clean up and put new screws in. Be care when removing the plastic lock tab on the circut board it breaks easely. If it does no big deal just make sure the connection is pushed in all the way. test your handy work before buttoning up. The solenoid comes with a new plunger so don't worry about cleaning the old one. The screws do not come with.
Parts Used:
-
Richard from Coppell, TX
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers
2 of 3 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Light out
Turned off the breaker to the fridge because I couldn't reach the power plug to unplug it . Use small flat head screwdriver to pop out the piece, disconnected the rubber prong connectors, inserted the new piece into the rubber prongs snapped it back into place. Flipped the breaker back on and prayed it worked. It did and I saved myself $120 service call.
Parts Used:
-
Jodi from Benton Harbor, MI
-
Difficulty Level:Very Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Pliers, Screw drivers
2 of 3 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
brand new ge refrigerator delivered with broken access cover. cost 6.95 so i repaced it myself.
-
Gerald from Shelton, CT
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Nutdriver
4 of 9 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
was not able to get water out of the dispenser or the ice maker
Very simple fix. Just remove the back cover, unscrew the water valve, unplug the water valve and disconnect the water line. Then reinstall the new one. Takes about 15 to 20 min and it worked like a champ
Parts Used:
-
Darren from Riverside, CA
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver, Socket set, Wrench set
2 of 3 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
the cecular door for the ice was geting stuck opened
with a small screwdriver push in tabs in upword movement to remove the face cover for the three botons of ice crushed ice and water .
once removed remove four screw to take out the circular door .
solinoid plunger will be atached to the door and it has to screws holding the solinoid .
instolation is the oposit steps of removing the part
once removed remove four screw to take out the circular door .
solinoid plunger will be atached to the door and it has to screws holding the solinoid .
instolation is the oposit steps of removing the part
Parts Used:
-
john from st aug, FL
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Socket set
2 of 3 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water dispenser inoperative
Replaced Double Outlet Water Valve then defrosted coiled plastic water tubing at bottom position inside refrigerator into pan of hot water for 10 minutes. Water still did not flow. Defrosted refrigerator and water dispenser immediately resumed operation. Suggestion -
defrost refrigerator first.
defrost refrigerator first.
Parts Used:
-
Gregory from The Villages, FL
-
Difficulty Level:Really Easy
-
Total Repair Time:1- 2 hours
-
Tools:Nutdriver
2 of 3 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice wouldn't come out of door. It backed up in door
I followed the instructions on a posted desctiption. It workded perfectly. Replacing the inner door panel was not as difficult as described. Just start the process with the screws in the middle of the door. Those two screw holes were not slots. All of the remaining screw holes had slots. I installed all of the door screws before tightening any. I workded right the first time.
Parts Used:
-
Stephen from Richmond, VA
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:1- 2 hours
-
Tools:Nutdriver, Screw drivers, Socket set
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Replacing Ice Maker in GE French Door Bottom Freezer Fridge
The best instructions were several YouTube videos for replacing icemakers on GE french door bottom freezer refrigerators, but none fully described the process. The following difficulties were encountered: (1) Instructions for removing the freezer door showed three screws on each side that needed to be removed; in fact, there was only one screw on each side. It was smaller than the three depicted screws and its location was not exactly as shown in the videos. (2) None of the instructions adequately described the process for removing the mounting plate from the nonfunctioning icemaker so it could be attached to the replacement unit. The key was to forcibly pry open the cover over a screw that then needed to be loosened with a screw driver. It seemed that I risked breaking the unit when I tried to slide the tab, but it eventually moved and revealed the screw that was holding the original mounting plate in place. (3) Replacing the freezer door required lining up some metal studs with slots in the undercarriage; you need to get down on the floor to examine how this fits back together. (It might help to take some photos before removing the freezer door.) (4) Replacing the upper drawer was perhaps the trickiest. My first effort resulted in having the rod with gear pinions on each end pop out because some of the tabs holding the gear pinions on each end broke. That meant that I had to order two replacement gear pinions (left and right are identical). Then, as with the freezer door, it was necessary fo slide metal studs on each side into a vertical slot leading to a horizontal slot in order to seat the upper drawer properly. So the whole process took a few weeks; actual work time was perhaps 3-4 hours. This could have been shortened significantly had I taken photos as I disassembled everything and if the procedure for moving the mounting plate had been clearer (or even existing). All in all, though, this is a doable DIY project.
Parts Used:
-
David from WOODSTOCK, NY
-
Difficulty Level:Difficult
-
Total Repair Time:More than 2 hours
-
Tools:Screw drivers, Socket set
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Opend freezer door and found ice everywhere from dripping ice maker. Even with power unplugged water was still leaking through so I determined it must be the water valve at the back of the fridge that had failed.
Unplugged fridge. Shut off the water supply valve under sink. Removed lower access panel at back of the refrigerator (six screws). Removed single green screw holding water valve bracket and pulled assembly out to access wiring and hoses. It is a dual valve as one valve is for the water dispenser and one is for the ice maker. Disconnected the 2 electrical connectors (one for each valve). Unscrewed the compression fitting for the water inlet with 1/2 " wrench. Then the two water lines on the outlet which are quick disconnects. You must push the ring towards the valve and then the tubing can be pulled out by hand.
Reattach everything to the new valve and install and its ready to use.
Reattach everything to the new valve and install and its ready to use.
Parts Used:
-
Doug from Madison, WI
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Socket set, Wrench (Adjustable)
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water running out of ice cube maker
After turning the water off, I removed the silver covering located on the left side bottom. The valve was connected to the frame on the left side. I removed the defective valve and replaced it with the new one. Everything was color coded and the hoses were different sizes, making it impossible to screw up. It was over so fast I thought I made a mistake.
Parts Used:
-
Glenn from Pembroke, NH
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Pliers
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
ice dispencer door will not closeremoved hte control panel
removed the control panel ,using a paper clip, removed five screws, disconected wire connector, and removed the solenoid. reversed procedure to reassemble. ordered the part one day and received it the next day. Thank you for the prompt response.
Parts Used:
-
robert from kansas city, MO
-
Difficulty Level:Really Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Screw drivers
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!