Freezer And Frig Both Warm And Compressor Would Not Run
I replaced the thermostat, temperature sensor, and the run capacitor. . . Refrigerator still not cooling. I checked the start relay and measured the input terminals on the compressor for the correct resistance. . . Everything measured correctly. In a last ditch effort before calling for service, I pulled the main board, inspected it and saw the problem right away. One leg on the compression capacitor had desoldered itself. Got out my soldering iron and applied a good amount of solder to that point. Put everything back together and turn it on. . . Problem fixed. The compressor kicked on right away and started cooling the refrigerator.
Parts Used:
Run Capacitor
  • joe from decatur, GA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Wrench (Adjustable)
Was this instruction helpful to you?
Thank you for voting!
My fridge was colder than my freezer
I can't tell you how luck I feel after finding your website I ordered the temperature sensor after watching one of your videos on-line and the repair went just as on the video. I pulled the "bad" sensor out, and replaced it with the new one. Keep in mind that this is the first time I ever touch an appliance, needless to say I'm feeling pretty good about that! All in all it took me about 20 minutes to complete my repair and it now has been about 4 days and the refrigerator is working like new again!
Parts Used:
Temperature Sensor
  • Marco from Fallbrook, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers
Was this instruction helpful to you?
Thank you for voting!
refriger warm
replace sensor in refriger.
Parts Used:
Temperature Sensor
  • chol from Glenview, IL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Would not self defrost.
Remove the shelves then remove the back by removing the two screws at the top of the panel. Locate the temperature sensor on top of the coil. Cut the wires and replace with the new one. Use wire nuts and electrical tape to reconnect the wires.
Parts Used:
Temperature Sensor
  • Greg from Rockwood, TN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
Was this instruction helpful to you?
Thank you for voting!
fridge to warm
followed part select video instructions
Parts Used:
Temperature Sensor
  • Michelle from Chimacum, WA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers
Was this instruction helpful to you?
Thank you for voting!
The frig was not cooling in main section or freezer
I ordered 3 temperature Sensors Part#PS304103 and viewed the video. Got there, opened the frig. and it looked totally different and no place in any part of this frig. that took these sensors as viewed on the video. Totally baffled why these parts were listed for this frig. there was no place in this frig that would access for these parts. Serial # was HR443071.Maybe this model is out of date for these parts. Trying to find someone who can repair it. Any ideas???Purchased this GE in 2008. Model #is GSS25WSTFSS Thanks, for your help. JIM
Parts Used:
Temperature Sensor
  • James M. from Belfair, WA
  • Difficulty Level:
    Very Difficult
  • Total Repair Time:
    More than 2 hours
Was this instruction helpful to you?
Thank you for voting!
no light in freezer
Connected the 2 wires and pushed in the switch until it clicked.
Parts Used:
LIGHT SWITCH
  • christopher from collegeville, PA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
Was this instruction helpful to you?
Thank you for voting!
Both the fridge aqnd freezer would not get cold.
Easy. Followed the video instrucations. the part was right there next to the compressor.
Parts Used:
Run Capacitor
  • Mary from Farmingdale, NY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
defrost problem (refrigerator/freezer not cooling)
After replacing the Defrost Thermostat, Defrost Heater Assembly, and the Main Board, I concluded that the problem must be the Defrost Thermistor, which I replaced in less than 10 minutes and it fixed the problem! I cut the wires on the old thermistor and connected the new one after stripping the wires and taped the new connections with electrical wire. Fast and easy repair (the last part anyway ;).
Parts Used:
Temperature Sensor
  • Gordon from Sugar Grove, IL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
refig light did not work
per your instructions
Parts Used:
LIGHT SWITCH
  • paul from east hanover, NJ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
coils were icing up and refrigerator section was warm freezer was cold
Unplugged unit and removed vented cover over compressor section. The run capacitor is a simple fix 1 Phillips head screw and 2 spade wire connectors. For the temperature sensor I had to remove all drawers and the ice maker to remove the back cover to expose the condenser. Put a bowl at the drain stem in the rear of the unit and used a heat gun to defrost the coils on the condenser. Cut the wire about 3" from the sensor end . cut about the same off the new sensor stripped the wires put shrink wrap on each wire, attached butt connecors . heat gun for the shrink wrap and reassembled everything. Simple job that took about a half hour to do both. I will monitor the fridge for a couple of weeks to see if I need to change the control board.
Parts Used:
Run Capacitor Temperature Sensor
  • Chuck from TARRYTOWN, NY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
failed light switch
I started removing the switch by prying on the right side with a screwdriver, when it emerged enough I used pliers to finish removing it. I then unpluged rhe wires from the bad switch and pluged them on the new switch and "poped" it into the hole.
Parts Used:
LIGHT SWITCH
  • Jules from Crowley, LA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
coil frosting up and refridgerator section was not cooling
took out shelves and removed the back plate my removing 2 screws with a nutdriver.removed the old defrost timer and defrost heater which was really easy.then installed the new ones.the video i watched on the website was really helpfull.
Parts Used:
Temperature Sensor
  • Vernon from Harmony, NC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
frige too cold
changed sensors did not repair problem,replaced damper with mechanical damper fixed problem.
Parts Used:
Temperature Sensor
  • John from Island Lake, IL
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Defroster stopped working and iced up evaporator coil
I have a GE Profile French door refrig. It's only about 4 yrs old and the defroster stopped working. I read the other repair stories and was able to narrow it down to either the temp sensor, defrost timer, or main board. The refrig section was up to about 47 degrees and freezer was around 25. I could tell it was trying to cool but couldn't. So I tried the temp sensor first. I cut and spliced the new sensor on the outlet of the Evap. Coil and it took about 15 mins. Turned refrig back on and waited. The coil started to ice over after about 5 hrs I left the back panel off so I could see if and when then heater kicked on. After about 8 hrs I looked in and saw a faint glow and water trickling down and running out the drain. Turned out the sensor was bad and wasn't telling the main board it needed to defrost. I would try the sensor if you are having the same issues before spending a lot of money on the main board, defrost heater and or timer.
Parts Used:
Temperature Sensor
  • Brandon from Bruceton Mills, WV
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers, Screw drivers, Socket set
Was this instruction helpful to you?
Thank you for voting!