Models > M05B > Instructions

M05B (V2) Frigidaire Freezer - Instructions

All Instructions for the M05B
106 - 111 of 111
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Heard a five second buzzing sound repeated 4 or 5 times per cycle coming from rear lower left compressor side.
Removed the six screws holding the bottom access plate found at the rear of the refrigerator. This gives you easy access to the run capacitor that has a retaining clip. Remove the wire clip and pull out the capacitor (it has two quick disconnect terminals). Reverse the process using the new run capacitor to complete the repair.
Parts Used:
Refrigerator Capacitor
  • Burton from Pecatonica, IL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
Was this instruction helpful to you?
Thank you for voting!
Switch didn't work
followed the video as instructed. Saved two repairman calls, one to find the problem, one to install. Net savings was about $130.00
Parts Used:
Refrigerator Door Switch
  • Don from Laramie, WY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
Was this instruction helpful to you?
Thank you for voting!
Broke the arm off the food compartment rocker switch
After receiving the new part almost immediately,using two screw drivers, removed the broken switch from the plastic frame. Be careful not to scratch or otherwise tear the plastic...very pliable. Since the original switch was factory installed and the wires were packed in fiberglass insulation, the switch came out but the wires and clips were still in place and could not reach the new switch. It was necessary to pull them down with bent long nose pliers...used a lot of "pull" but the wires held up.Connected the switch, turned the power on and there was light! Reports from other users really took the uncertainty out of the task.
Parts Used:
Refrigerator Door Switch
  • David from St. Pete Beach, FL
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
light socket in fridge corroded, kills light bulbs
The old light fixture and socket were easily removed. This was done with the power connected, but I already knew the switch didn't need to be handled. The solderless connectors are all insulated, so I just had to be careful. The new socket would not accept the connector for the "hot" (red) wire in the fridge, due to a design change. This is, of course, why you furnished a loose 3/16 inch crimpon connector. Rather than cutting the red wire (remember, the power is still connected), I obtained an insulated 3/16 connector of the opposite gender, and a short piece of red-insulated wire from an old fluorescent tube ballast, and made a jumper. The connector I provided (male) did not fit tightly in the original fridge connector, so I put a layer of resin-core solder on my male connector. You need tight connections. If the solder layer is too thick, it's easy to file down. Make sure to heat the solder sufficiently that the solidified solder is shiny and not dull gray. I used a 100-watt gun. 20 watts would probably work too. DO NOT USE ACID-CORE SOLDER OR FLUX ON ELECTRICAL WORK! I knew the switch was good, because I had checked for voltage at the socket terminals using my voltmeter, before I ordered the socket. It read 120 volts every time the door switch was open, and zero volts every time the door switch was pushed closed. A simple voltage tester would work here, too. Be very careful if you do this test or this repair with the power connected to the fridge; there is considerable potential to find yourself touching 120 volts with one hand while your other hand is touching a perfect "ground". There doesn't seem to be any choice if you want to test the switch. You do have a choice with the socket replacement - - the jumper described above. If you're not going to use the jumper approach, cut the power! If you are going to make a jumper and are not comfortable working on a "live" circuit, cut the power.
Parts Used:
Single Lamp Socket Kit
  • Lynn from Phoenix, AZ
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers
Was this instruction helpful to you?
Thank you for voting!
Burned out defrost coils
removed back sheet from inside of freezer unit. removed upper and lower coil brackets. undid clips and replaced coils. reattached wires to top , replaced back sheet.
Parts Used:
Defrost Heater - 500W 115V
  • Ralph from Randolph, UT
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Socket set
Was this instruction helpful to you?
Thank you for voting!
Both light bulbs had been replaced, but lights did not turn on.
I tried to remove the old light switch using a putty knife and a hammer. It was hard to compress the plastic tabs to pull it back through the hole, but all of a sudden, the lights came on. I guess banging on the switch freed-up the contacts. The new switch is now a spare part in case I need it.
Parts Used:
Refrigerator Door Switch
  • Richard from Arlington, MA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the M05B