Models > KUIC15PLXS2 > Instructions

KUIC15PLXS2 KitchenAid Ice Maker - Instructions

All Instructions for the KUIC15PLXS2
106 - 114 of 114
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
The old condenser fan was rattling and driving everyone nutts.
I surfed partselect and read that a reader had a similar problem with a rattling fan. I then removed the back panel, after I had unplugged the unit, and was able to feel the slop in the fan shaft. I then watched the video of how to replace the fan and ordered the part soon after. The part arrived 3 days later! Easy to do. I was finished in 12 minutes and the fridge runs silently. The part of the job that took the longest was vaccuming the undercarriage. There was alot of dust! Couldn't have helped the efficiency on the fridge. Keep it clean.
Parts Used:
Condenser Fan Motor Kit
  • William from Salem, WI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Wrench set
Was this instruction helpful to you?
Thank you for voting!
Very noisy operation
Removed and replaced the condenser motor fan kit. This was a very easy tear down and replacement of a bad component. Removed 4 screws to remove the bracket holding the fan motor kit pulled it out and replaced with the new unit (4 screws supplied) plgged in adapter cord (supplied) and re-installed took about 10 minutes.
Parts Used:
Condenser Fan Motor Kit
  • Mike from Coon Rapids, MN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
Was this instruction helpful to you?
Thank you for voting!
cutting grid wire broke
Bought new wire, strung it end to end and fastened it at each end.
Parts Used:
Ice Cutting Grid Wire
  • Dean from Anchorage, KY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Socket set
Was this instruction helpful to you?
Thank you for voting!
Water bucket had cracked and leak
Remove pump and hoses from bad bucket, removed bucket and install new bucket . To remove pump, remove screw holding pump and turn pump 1/4 turn. Be careful Putting new bucket back, can break hose if not careful. Good luck
Parts Used:
Water Bucket
  • Mitchell from Danville, KY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
removing broken cutter grid
The thumbscrews that hold the cutter grid can only be removed by using a needle nose pliers , you cannot turn them by hand. The electrical connections for the grid and level sensor can be removed by pressing the front side of the connector while pulling down. Re-installing the cutter grid is in reverse to the removal, just follow the instructions. But be aware that all wiring remains outside the grid perimeter when reconnecting. One other thing: While you are at it, remove the lower outside panel to expose the evaporator coils which need to be vacuumed. Replacing these parts is tricky. I had to remove the door then loosely install the upper retainer bracket for the lower panel so I could slide the upper edge into that bracket before installing the lower screws. I used an ice pick to line up the holes while using a blade screwdriver to push the panel in its place to install the retaining screws. It took me about a half hour after I figured out what to do.
Parts Used:
Complete Ice Cutter Grid Assembly
  • Juergen from Belle Chasse, LA
  • Difficulty Level:
    Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Recirculating pump stopped working
Remove ice tray and guard over moter. Un plug the 3 plugs and pull the entire motor assembly out. Use a screw driver to gently pry motor out. Snap in the new motor(the wiring was on the wrong side and the power cord coloring backwards on the replacement motor, but I snapped it in with the colors criss crossed and it worked). Re plug in the 3 plugs. Re mount mounting assembly, tray and then guard. Had a little trouble getting the tray back in. There is a little flap in the back that goes inside the tray. Other than that, a pretty easy fix.
Parts Used:
PUMP
  • Gene from Battle creek, MI
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
Was this instruction helpful to you?
Thank you for voting!
refrigerator on and off
as told per compter
Parts Used:
Condenser Fan Motor Kit
  • Anthony from Culpeper, VA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Machine Quit Producing Ice
Trouble shooting discovered no water going to into the unit, decided to replace water valve which fixed the problem.
Parts Used:
Water Inlet Valve
  • RONNIE from ODESSA, TX
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Pliers, Screw drivers, Socket set, Wrench set
Was this instruction helpful to you?
Thank you for voting!
No ice, the cabinet was warm, but most annoying it broke every 6 mos since I got it
I replaced the thermometer first and it started working again. I was convinced that the reason that it continued to break every 6mos was because no one had ever replaced the fan. The difficult part was getting to it. After trying to get in from the front and from the back I finally figured out that I had to take the bottom off and tilt it on its side. I was then able to get out the pin in the condenser and move it to the side. I could then reach the screws that held in the fan. I then decided to put the fan on the motor and when I was tapping it on with a hammer the back cracked. I attempted to fix it by taking apart the old motor and salvaging the parts but that didn't work. I had to buy another $85 part and take the whole thing apart again. It was easier the second time because I knew which screws and pins I had to remove and how to get to them. I very, very carefully tapped the fan onto the motor and now it is working fine. I will let you know if it is still working at Easter. If it is I will have done a better job than the 7or 8 repairmen who have fixed it in the past
Parts Used:
Condenser Fan Motor Kit
  • Cynthia from Wilmington, DE
  • Difficulty Level:
    Very Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Screw drivers, Socket set
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the KUIC15PLXS2