Models > KP2671XWH3 > Instructions

KP2671XWH3 KitchenAid Mixer - Instructions

All Instructions for the KP2671XWH3
121 - 135 of 141
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Stripped worm gear
Looked at the schematic for this model on Parts Select. Removed Aluminum band screw, removed the 4 screws that hold the top of the mixer. Lifted the top off. Removed 4 screws and lifted the gear case. Removed snap ring and took off tapered gear. Removed pin and removed worm gear. Picked out the metal, in the grease, from the old worm gear, using a magnet then inserted new worm gear and put it back together in reverse order. There was plenty of grease and didn't need to add any.
Parts Used:
Worm Following Gear
  • Johna from Ketchikan, AK
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Speed control stuck from sugar/flour build up on slide
Took housing off, removed computer board and disconnected speed control assembly from board. Soaked plastic slide in hot water and freed up mech. Discovered a crack in plastic slide from forcing it. Ordered new assembly and installed. TIP: Keep slide clean of substances that will jam it by cleaning occasionally with water. For a complete cleaning you will have to remove it. Total of 6 easy to reach screws.
Parts Used:
Stand Mixer Speed Control Board and Knob (Black)
  • David from Dekalb, IL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Worn gears
Took mixer apart and then the gear compartment. inspected components. Replaced the worn gears and re-greased the new parts. Put the gear compartment back together, tested the operation of the unit and then replaced the rest of mixer, re-tested and declared victory.
Parts Used:
Mixer Retaining Pin Mixer Retaining Ring Hub Gear Hub Gear Stand Mixer Gear Grease
  • Ronald from Spring Field, VA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
no power and have bad noise
remove the cover,take out four screw from gear box,remove the gear box,clean all gears,then you see damage gear,replace it ,install new grease.
Parts Used:
Mixer Worm Gear Worm Following Gear
  • Man fui from East Brunswick, NJ
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Gears worn and Speed control sensor
I have to thank you at Partselect.com. You happen to help me help other people. Now I have several people bringing me their Kitchenaids to me instead of sending them in. I replaced two worm gears on a Kitchenaid 6 and the Hall sensor on a Kitchenaid 5. Very easy to do. Next week I have another Kitchenaid 5 to replace the motor on. Thankyou again for having the parts I need
Parts Used:
Mixer Drive Motor 10 Tooth Mixer Worm Gear Worm Following Gear
  • robert from san antonio, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Drive shaft separated from the planetary
Open the case, removed gear cover, removed planetary drive shaft and gear, replaced with new planetary and reassemble.
Parts Used:
Planetary (Cobalt Blue)
  • Ann from Chico, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Mixer stopped working and gave grinding sounds
Following Replacement Part Youtube instructions, I disassembled the mixer and found what caused the sounds and prevented the mixer from operating. The worm follower gear had been ground down by the worm gear. I found that the shaft from the planetary gear had not been adequately greased and siezed preventing the worm follower gear from turning. The worm gear is obviously made of harder material and thus, was able to wear away the follower. I appreciate the your help which saved having to replace a perfectly good/expensive mixer. Thanks.
Parts Used:
Worm Following Gear
  • brian from carlsbad, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
worn teeth on worm gear. beater not turning
took off the strap band around mixer, took off the cover (4 screws, took off gear cover (4 screws) took off the retaining ring(used pliers and screwdriver) took off upper gear, took out retaining pin, took off lower gear (becareful to grab the planetary assembly as it will fall out after you take out the retaining pin) cleaned out all of the gear grease (the teeth that were missing were in it. replaced the planetary assembly, lower gear and retaining pin. replaced the upper gear, replaced the retaining ring (used screwdriver and hammer. you have to spread the ring with end of screw driver so it will fit on the shaft then tap lightly with screwdriver and hammer to get it down to the keyway for the ring.) replaced the gear grease with NEW grease, reaplaced the gear cover, replaced the mixer cover, replaced the strap band and plugged it in to test it. IT was quieter than before and works great. i spent less than $30 to repair my 10 year old, out of warranty, Kitchen Aid Mixer. much better than the $32.00 to ship it to factory repair shop and get an estimate to repair. I needed it to make a cake for my nephews wedding. I had my parts in 2 DAYS!!! it was a great experience over all.
Parts Used:
Mixer Retaining Pin Worm Following Gear Mixer Retaining Ring Hub Gear
  • Joanna from Tower Hill, IL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Thumb screw
the plastic covering the thumb screw cracked almost half way and lost the piece....so the new one is being used to replace this old one...very easy to install
Parts Used:
Mixer Thumb Screw
  • Linda from Lynden, WA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
Was this instruction helpful to you?
Thank you for voting!
missing part
just attached it
Parts Used:
Flat Metal Beater
  • Bill from Charlotte, NC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
Was this instruction helpful to you?
Thank you for voting!
Mixer goes full speed even when on low setting.
Removed one screw to remove deco band around mixer body. Removed four screws under band to remove mixer top. Removed two screws holding switch. Removed wires one at a time putting them in the same position on the new switch. Re-attached switch, mixer top, and deco band. Works perfectly.
Parts Used:
Stand Mixer Speed Control Board and Knob (Black)
  • JOHN from RIVERSIDE, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
worn gear causing slippage under load
removed cover. Removed cover over gears. Used lock washer pliers to remove lock washer. Took out gears. Cleaned metal shavings from old gear and grease. Reassembled using new gear. Took about 15 minutes and saved $$ over sending mixer out for the repair.
Parts Used:
Worm Following Gear
  • Rodney from Thornton, NH
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Mixer wouldn't slow down
I unplugged the mixer, then I removed the Phillips screw holding the beauty ring, then removed the 4 screws that hold the motor housing together. I removed the housing top, and unscrewed the speed control switch. I marked each one of the connectors of the switch (there are 4) 1-4 then disconnected the speed sensor from the switch and the motor. Replaced the new sensor and connected that to the new speed control switch. reconnected the connectors to the terminals I took them from ( 1 - 4 ) screwed it into place. replaced the top motor housing, I screwed that back with the four screws. replaced the beauty ring and screw. plugged it in and tested it and it was like new
Parts Used:
Stand Mixer Speed Control Board and Knob (Black) Stand Mixer Speed Control Board and Knob (Black)
  • Sal from STATEN ISLAND, NY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
head of screw was broken in half
I looked on line found the product sent in information and 3 days later was in my mailbox,great service and ease of ordering. thanks marjorie
Parts Used:
Mixer Thumb Screw
  • marjorie from juda, WI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
Was this instruction helpful to you?
Thank you for voting!
Trouble with switch
removed top casing, removed old switch and sensor,and replaced with new ones. It was just a matter of a half dozen screws and unpluging 4 or 5 wires and then reversing the process. Couldn't be easier. thank you
Parts Used:
Stand Mixer Speed Control Board and Knob (Black) Stand Mixer Speed Control Board and Knob (Black)
  • Dawn L from Ceres, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the KP2671XWH3