Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
All power to the microwave went out.
PartSelect had helpful repair instructions on-line which made the repair easier and faster. Unfortunately, there were other problems with the oven that immediately blew the new fuse I had just installed. It was then determined that additional repair would most likely cost almost as much as a new microwave.
Parts Used:
Microwave Fuse
  • Michael from East China Township, MI
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
F2 error code
Really easy fix. Unplug oven. With a 5/16 nut driver take the 5 screws out of the center long tin cover and remove. Unplug little white temperature sensor plug located between broil heating element. Open oven door and remove one screw holding temp. sensor using same nut driver and simply pull out old sensor. Install new sensor. It's that easy. No more f2 been working like a champ!!!
Parts Used:
Temperature Sensor
  • jud from gatesville, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
Was this instruction helpful to you?
Thank you for voting!
Flashing F2 and erratic temperature readings.
Unplugged from wall outlet, then opened oven front door. Reached in and removed two screws. Pulled oven sensor threw and detached electrical connector from old sensor. Plugged in new oven sensor and reversed removal procedure. No more Flashing F2 and oven temperature came to ready. Very easy.
Parts Used:
Temperature Sensor
  • Kenneth from Salem, OR
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
Was this instruction helpful to you?
Thank you for voting!
microwave won't heat
bought a fuse but that didn't solve the problem. Guess I need a new microwave
Parts Used:
Microwave Fuse
  • Stephanie from Kernersville, NC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
oven not warming, f2 indicating overheat
Removed 4 screws from back panel, disconnected small electricsl connector from sensor, removed one mounting screw from sensor inside oven,pulled wires through and removed old sensor. Fed wires for new sensor through and connected electrical connector, installed panel, installed mounting screw on sensor and checked oven, worked like a champ. Took 5 minutes.
Parts Used:
Temperature Sensor
  • David from Lisle, IL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
Was this instruction helpful to you?
Thank you for voting!
Turntable roller replacement
This was as easy as it gets. The whole process took seconds to complete. Simply remove the old roller and install the new one. It was wonderfully easy.
Parts Used:
Turntable Roller Guide
  • Nicholas from Durham, NC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
Was this instruction helpful to you?
Thank you for voting!
Not heating
Removed the above stove microhood. Removed the side panels & the top panel. Diode located on right hand side of microwave. Removed with screwdriver & replaced new diode. It's best to get the microwave schematic online to pinpoint location of the part.
Parts Used:
Diode
  • Debra from Concord, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
I had a broken turntable roller quide under the glass plate
opened the microwave door, removed the glass plate, removed the bad roller quide, replaced with the new one, replaced the glass plate and then closed the door. :)
Parts Used:
Turntable Roller Guide
  • Danny from Glendora, MS
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
Was this instruction helpful to you?
Thank you for voting!
Microwave died-no display-15amp fuse blows
I shut off power to the microwave, discharged the Hi-voltage capaciator and disconnected the wires to it, then removed the screw and bracket that held the capaciator in place. After removing and replacing the capaciator, reattaching wires and mounting bracket, and replacing the 15amp fuse, the microwave woked fine.
Parts Used:
Microwave Capacitor
  • David from Hot Springs Village, AR
  • Difficulty Level:
    Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Pliers, Screw drivers
Was this instruction helpful to you?