Leaking solenoid operated water value on ice maker.
Removal of old valve very easy and accessible, 2 screw/bolts for mounting, disconnect to electrical leads by hand, disconnect 2 plastic water lines with push/pull connectors and reverse order for installation. Total time-less than 5 minutes and basically no tools required expect pliers or nut drive to loosen screw/bolts. Just turn on and it was making ice
Parts Used:
Ice Maker Water Inlet Valve
  • Robert from Nashville, TN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers
Was this instruction helpful to you?
Thank you for voting!
Water Was Leaking Into The Control Board
I removed the inspection cover, removed 2 screws holding the control valve,depressed the realease rings on the water lines,unpluged the 2 electrical connections and removed the bad valve. I re-installed the water lines into the new part, reconnected the electrical plugs,replaced the 2 screws in the new valve keeper and replaced the inspection cover. Everything I received from partselect fit perfectly. Thank you partselect, the ice machine works great. I sure was glad you were there. Thanks,, alfred harvey
Parts Used:
Ice Maker Water Inlet Valve
  • Alfred from Hot Springs, AR
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Ice maker would not make Ice.
Took out one strap support with a nut driver, unplugged the device and plugged in the new one. Reinstalled the support strap. Job complete.
Parts Used:
Thermistor
  • Paul from Paige, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
Was this instruction helpful to you?
Thank you for voting!
Water was not circulating to the freeze area
Easy. I took a picture with everything in tact. Took apart a couple of parts with screw driver. Replaced the pump. Put it all together and it worked fine.Thanks.
Parts Used:
PUMP
  • Jerry from Frisco, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Water Leaking From Under Icemaker
Removed lower vent cover and removed valve. Removed water lines and power hookups and attached to new unit. Approx. 15 Minutes total repair. Checked for leaks. Finished. Part select had replacement valve to my door within 24 hours. Great service and simple to understand installation instructions. Highly recommend.
Parts Used:
Ice Maker Water Inlet Valve
  • Keith from Paducah, KY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
our ice maker stopped working
I am the canteen manager at a V.F.W, our ice maker stopped working and I had an appliance technician come in and see what was wrong with it. The technician told me I needed a new compressor costing around $500.00. The next day I pulled out the ice machine and noticed there was condensation dripping on the start relay. I pulled the start relay from the compressor and saw a lot of corrosion. I then sealed the leek and cleaned the pins on the compressor. I ordered a new $40.00 start relay (which came in no time) and installed it. It works perfect.
Thanks Brian
Parts Used:
Start Relay & Overload
  • brian from columbus, OH
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
loud noise coming from back of fridg.
Unplug A C Cord . Simply unscrewed lower back cardboard cover panel and unscrewed condenser fan motor , removed wiring plug , pulled fan motor out removed fan blade and put it on new motor . then I Reinstalled motor. Noise is gone . EASY INSTALLATION .
Parts Used:
Condenser Fan Motor Kit
  • William from Fort Mohave, AZ
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
Was this instruction helpful to you?
Thank you for voting!
Recirculating pump stopped working
Remove ice tray and guard over moter. Un plug the 3 plugs and pull the entire motor assembly out. Use a screw driver to gently pry motor out. Snap in the new motor(the wiring was on the wrong side and the power cord coloring backwards on the replacement motor, but I snapped it in with the colors criss crossed and it worked). Re plug in the 3 plugs. Re mount mounting assembly, tray and then guard. Had a little trouble getting the tray back in. There is a little flap in the back that goes inside the tray. Other than that, a pretty easy fix.
Parts Used:
PUMP
  • Gene from Battle creek, MI
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
Was this instruction helpful to you?
Thank you for voting!
Water bucket had cracked and leak
Remove pump and hoses from bad bucket, removed bucket and install new bucket . To remove pump, remove screw holding pump and turn pump 1/4 turn. Be careful Putting new bucket back, can break hose if not careful. Good luck
Parts Used:
Water Bucket
  • Mitchell from Danville, KY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
condenser fan would not come on, and when it did, made loud noise.
Repair was so simple, I didn't even need instructions. Removed old fan with motor, installed new one, installed harness that converted plugs, done. Saved hundreds of dollars doing the repair myself.
Parts Used:
Condenser Fan Motor Kit
  • Sean from Simi valley, AL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Socket set
Was this instruction helpful to you?
Thank you for voting!
Noisy fan motor
Before I began I unplugged the electrical at the wall outlet. 1. Unscrewed the 4 mounting screws. 2. disconnected electrical at the motor. 3. removed the assembly. 4. mounted the new motor on the assembly as described in the instructions. Installed the assembly and reconnected the electrical. Works great, easy job!
Parts Used:
Condenser Fan Motor Kit
  • eBooks4u from Wimberley, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Wrench (Adjustable)
Was this instruction helpful to you?
Thank you for voting!
Unit very noisy when running sometimes and then get quiet the noise would vary
Remove back panel on unit locate condenser fan and motor remove three small screws holding motor assembly to metal bracket disconnect electrical connection press new fan blade on new motor reverse directions
Parts Used:
Condenser Fan Motor Kit
  • william from glen gardner, NJ
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Socket set, Wrench set
Was this instruction helpful to you?
Thank you for voting!
My undercounter ice machine grid cutter wire broke
I removed the two screws that hold the shield in front of the grid and put them aside allowing access to the grid. I then removed the two screws that hold the grid in place. I unplugged the connector and then pulled it out. I reversed the process to reassemble and powered up the unit. I now have ice again. This whole process probably took me 15-20 minutes to do the install.
Parts Used:
Complete Ice Cutter Grid Assembly
  • Ronnie from Corpus Christi, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
Was this instruction helpful to you?
Thank you for voting!
cutting grid wire broke
Bought new wire, strung it end to end and fastened it at each end.
Parts Used:
Ice Cutting Grid Wire
  • Dean from Anchorage, KY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Socket set
Was this instruction helpful to you?
Thank you for voting!
removing broken cutter grid
The thumbscrews that hold the cutter grid can only be removed by using a needle nose pliers , you cannot turn them by hand. The electrical connections for the grid and level sensor can be removed by pressing the front side of the connector while pulling down. Re-installing the cutter grid is in reverse to the removal, just follow the instructions. But be aware that all wiring remains outside the grid perimeter when reconnecting. One other thing: While you are at it, remove the lower outside panel to expose the evaporator coils which need to be vacuumed. Replacing these parts is tricky. I had to remove the door then loosely install the upper retainer bracket for the lower panel so I could slide the upper edge into that bracket before installing the lower screws. I used an ice pick to line up the holes while using a blade screwdriver to push the panel in its place to install the retaining screws. It took me about a half hour after I figured out what to do.
Parts Used:
Complete Ice Cutter Grid Assembly
  • Juergen from Belle Chasse, LA
  • Difficulty Level:
    Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers