JIM158XBCX0 Jenn-Air Ice Maker - Instructions
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
leaking water inlet valve
Received replacement valve ~ 3 days, easily replaced in less than 15min, works great
Parts Used:
-
Barton from Ringgold, GA
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Screw drivers, Socket set
4 of 15 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freeze ruptured inlet valve
Simple to replace. Next fall I will be sure to drain the outdoor icemake and shut it down for the winter.
Parts Used:
-
Lindey from Austin, TX
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Nutdriver
7 of 24 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
water leaking from water control board.
After turning off water to icemaker, defective control removed (two screws) and new unit installed.Worked perfectly.I was totally amazed when I ordered the part thursday afternoon and it arrived fridaY morning.Total time out of operation less than 24 hours.Wonderful results.
Parts Used:
-
otis from frenchburg, KY
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver, Screw drivers
0 of 10 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Condenser Fan was making noise
Having read a few of the user reports like this one gave me the confidence to do this repair. The space was really tight, but one of the write ups suggested removing the frame and then replacing the motor on the frame. That was an excellent suggestion. The only difficulty I had was when I used the motor screws from the old motor to install the new motor. They were slightly longer and didn't tighten down all the way. So the first "test" resulted in still having a noisy fan motor because it was shaking around a bit. But, taking it back out and using the screws that came with the new motor did the trick. The refrigerator is now whisper quiet all the time. I also appreciated the conversion wiring harness in the kit that was simply plug and play for this new motor to my old refrigerator.
Parts Used:
-
Kerry from Franklin, TN
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver, Socket set
Was this instruction helpful to you?
Thank you for voting!
Condenser fan vibrated loudly while turning
I pulled the back panel covering the fan and condenser off the refrigerator (just a few screws) and disconnected the fan which was a simple plug. The fan was held in place with three screws which I took out. I pulled out the old fan and replaced it with the new one, three screws to secure it in place and reconnect the fan plug. Then simply replace the back panel and plug the frig in. the fan silently started right up. Good as new and no service call! :)
Parts Used:
-
Robert from Aurora, IL
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver, Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Recirculating pump stopped working
Remove ice tray and guard over moter. Un plug the 3 plugs and pull the entire motor assembly out. Use a screw driver to gently pry motor out. Snap in the new motor(the wiring was on the wrong side and the power cord coloring backwards on the replacement motor, but I snapped it in with the colors criss crossed and it worked). Re plug in the 3 plugs. Re mount mounting assembly, tray and then guard. Had a little trouble getting the tray back in. There is a little flap in the back that goes inside the tray. Other than that, a pretty easy fix.
Parts Used:
-
Gene from Battle creek, MI
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver
Was this instruction helpful to you?
Thank you for voting!
Water bucket had cracked and leak
Remove pump and hoses from bad bucket, removed bucket and install new bucket . To remove pump, remove screw holding pump and turn pump 1/4 turn. Be careful Putting new bucket back, can break hose if not careful. Good luck
Parts Used:
-
Mitchell from Danville, KY
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver, Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Unit very noisy when running sometimes and then get quiet the noise would vary
Remove back panel on unit locate condenser fan and motor remove three small screws holding motor assembly to metal bracket disconnect electrical connection press new fan blade on new motor reverse directions
Parts Used:
-
william from glen gardner, NJ
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Socket set, Wrench set
Was this instruction helpful to you?
Thank you for voting!
condenser fan motor making alot of noise, possibly going out.
A bit of a tight squeeze for my hands, but very basic as I followed the instructions and watched the installation video. I only had the fridge unplugged for about 20 min..The fridge is as quiet, as it was brand new. The only tool I needed was the 1/4 inch socket wrench. A portable lantern was very helpful as well. Runs very quiet now, like new! Thx!!!
Parts Used:
-
rex from folsom, CA
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Socket set
Was this instruction helpful to you?
Thank you for voting!
Compressor fan and motor was load,barring was wobbling .
-
William from Fox lake, IL
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver, Pliers, Socket set
Was this instruction helpful to you?
Thank you for voting!
Loud condenser fan
Pretty much followed the how to video. Biggest pain was removing the screws to the bracket that houses the motor.
Parts Used:
-
Mike from Lake tapps, WA
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers, Socket set
Was this instruction helpful to you?
Thank you for voting!
our ice maker was not cutting the ice into squares.
I determined it was the cutter grid because there was a broken wire on the existing one. They have to heat up and cut the ice. I ordered it and the part was at my house in 1 day. The cutter grid part was easy to install. The ice maker is working great now.
Parts Used:
-
Scott from Phoenix, AZ
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver
Was this instruction helpful to you?
Thank you for voting!
Under counter Ice maler not making Ice
Had repair man out to make repair his price for part $219.00 and $271.00 labor as he was looking up his price I got on line and found part here for $121.00 thought it might take me 1 hour to fix only 6- 1/4" nuts 2 screws and less than 30 min I had Ice maker working. Bottom line my total cost $75.00 repar man $121.00 part $196.00 that was a savings of $294.00
Parts Used:
-
Ronald from Flowery Branch, GA
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
removing broken cutter grid
The thumbscrews that hold the cutter grid can only be removed by using a needle nose pliers , you cannot turn them by hand. The electrical connections for the grid and level sensor can be removed by pressing the front side of the connector while pulling down. Re-installing the cutter grid is in reverse to the removal, just follow the instructions. But be aware that all wiring remains outside the grid perimeter when reconnecting. One other thing: While you are at it, remove the lower outside panel to expose the evaporator coils which need to be vacuumed. Replacing these parts is tricky. I had to remove the door then loosely install the upper retainer bracket for the lower panel so I could slide the upper edge into that bracket before installing the lower screws. I used an ice pick to line up the holes while using a blade screwdriver to push the panel in its place to install the retaining screws. It took me about a half hour after I figured out what to do.
Parts Used:
-
Juergen from Belle Chasse, LA
-
Difficulty Level:Difficult
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver, Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Kit did not match up to existing bracket
fan motor housing had to be drilled through both sides of housing to attach to existing bracket. Possible damage to wiring inside the unit may disable condensor fan motor when motherboard is replaced. (Motherboard on order.)
Parts Used:
-
John from Severna Park, MD
-
Difficulty Level:Difficult
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver, Socket set, Wrench (Adjustable)
Was this instruction helpful to you?
Thank you for voting!