evaporator coil in freezer section fozen solid, refer not cool
To remove freezer door, push white tabs, inside rail toward back, remove door and rails as one unit. Unscrew plastic rail support on one side, remove ice maker, then back panel. Cut off thermostat, strip old leads, match colors, twist copper wires together, then crimp on new part using connectors provided. Reassemble, hardest part was figuring out how to remove freezer door. Check for continuity between heater lead and white terminal of icemaker plug just to make sure the heater is good while everything is apart.
Parts Used:
-
Michael from Tucson, AZ
-
Difficulty Level:Really Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver, Screw drivers
10 of 16 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Compressor would not start
Removed back access cover with quarter inch nut driver, unplugged wire harness, pulled old relay out & plugged in new one, reconnected wire harness, and reinstalled access cover. Piece of cake. (Shipping was very quick) ***Frig was only 3yr an 1 mounth old.*** Maytag - Dependable Huh?
Parts Used:
-
Rich from Monon, IN
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Nutdriver
7 of 7 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Not freezing or keeping thing cold in fridge
Once I got the right part the repair was quick and easy. All I had to do is get the old part off with a screwdriver and curved needle nose pliers and the old part came right off. The new part went in just as easy. Quick and easy. Less than 15 minutes.
Parts Used:
-
BRUCE from AMMON, ID
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Pliers, Screw drivers
8 of 10 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Power surge cause compressor to stop functioning
Followed the YouTube video linked to the Compressor Start Device and Capacitor I purchased. The repair was just as easy as the technician in the video said it would be. Removed the back panel, remove the clamp, worked the Compressor Start Device and Capacitor off the electrical prongs and replace it with the new one. After I reassemble the refrigerator, it was fully operational. Very easy to do and only required a few tools.
Parts Used:
-
Alvin from ORANGE PARK, FL
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Pliers, Screw drivers, Socket set
7 of 7 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
light not working in fridge
It was so easy!
Thanks for the rush to my home on the part.
I just unscrewed the plate that locks in the light switch (screwdriver) and unplugged the old faulty part and plugged in the new switch, screwed the cover back on and I was done!
Easy!
And I am not Mr. Fix-it!
Thanks for the rush to my home on the part.
I just unscrewed the plate that locks in the light switch (screwdriver) and unplugged the old faulty part and plugged in the new switch, screwed the cover back on and I was done!
Easy!
And I am not Mr. Fix-it!
Parts Used:
-
Michael from East Meadow, NY
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Screw drivers
7 of 8 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Damper wouldn't open in referigerator
Removed pop off plate inside top of refrig.
Removed 2 screws holding cover.
Removed cover and styrofoam piece
Unplugged wiring
Removed old part
Transferred wiring to new part
Replaced all parts.
Removed 2 screws holding cover.
Removed cover and styrofoam piece
Unplugged wiring
Removed old part
Transferred wiring to new part
Replaced all parts.
Parts Used:
-
William from Meredith, NH
-
Difficulty Level:Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Screw drivers
7 of 9 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator would cool for a very short period of time. Then the compressor would shutdown via internal thermal overload or high head pressure. This was caused by the lack of airflow across the condenser coils and compressor.
(1) Slide out appliance and remove power source. (2) Removed lower access cover on rear of refrigerator. (3) Disconnected plug to the condenser fan motor. (4) remove blades by pulling gently forward (5) remove mounting hardware holding the fan motor (3 screws) (6) motor is now free and new motor can be installed
Parts Used:
-
Daniel from RICHTON, MS
-
Difficulty Level:Very Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Nutdriver, Pliers
10 of 18 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Insulation was disintegrating.
On the back of the refrigerator, I unscrewed and removed the lower-right panel. As I peeled the insulation off the panel, the insulation would disintegrate, so I used a vacuum-cleaner hose to remove most of the insulation. I removed the remaining adhesive with my fingers. I peeled the backing off the new insulation, and stuck it to the panel.
I had ordered two pieces of insulation, hoping to also replace the insulation behind the compressor, but removing the compressor was complicated and risky, so I returned the second piece of insulation.
I had ordered two pieces of insulation, hoping to also replace the insulation behind the compressor, but removing the compressor was complicated and risky, so I returned the second piece of insulation.
Parts Used:
-
Julie from San Diego, CA
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers
6 of 6 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
broken light switch in the freezer
We removed the old switch, unplugged it, plugged the new one in and it was easy to do. But when we tried to put the switch back in we had a very hard time doing it. Eventually got it in, but if it had not been for the difficulty we had getting the new switch to snap in to place, it would have taken under 5 minutes.
Parts Used:
-
kathleen from GREEN VALLEY, AZ
-
Difficulty Level:Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Screw drivers
6 of 6 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
I accidentally damaged the power cord
The other guy described it perfectly so all I can add is that this repair was as simple as they come. Don't hesitate.
Parts Used:
-
Rob from Kalamazoo, MI
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver, Screw drivers
7 of 9 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator was not cooling. Damper would not open.
Removed damper vent by hand and then unscrewed 2 visible screws that hold Damper Control Unit in place. After removing screws, the damper control unit is easy to remove by unplugging 2 electrical connectors by hand and connecting new unit the same way. Screw the panel and snap the vent back in place and you're done!! Piece of pie, easy as cake...Ha! Ha!
Parts Used:
-
RODOLFO from EDINBURG, TX
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Pliers, Screw drivers
7 of 9 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
There was ice building up in the freezer.
I searched the internet for the correct part and reviewed the instructions on the internet. Upon ordering the correct part I was provided a link to a video that walked me through step by step. The very first thing I did was unplug the refrigerator.I then located the control board located in the housing in the ceiling of the refrigerator. Using a screwdriver I was able to carefully separate the housing from the refrigerator ceiling . Unplugged the housing and then had to separate the plastic housing to locate the control board. Ran into a little difficulty at first separating the plastic tabs but with a screwdriver carefully pried the tabs. Once completely open is where the control board was. More plastic tabs holding the control board in place. Carefully separated the board from the tabs. The were two plugs that needed to be separated from the board. Used a screwdriver to get the plugs separated.The new board you had to bend carefully at a joint so the board became two pieces. Snapped the boards in place. Plugged the board in two spots. Put the housing together and put the housing in place in the refrigerator. Plugged the refrigerator in. All lights came on and then had to program the board. The instructions were spit on. The code is located inside the fridge were the model tag is. Programmed correctly. Word of advice read the directions a few times you can't go wrong. So far it's day 7 after I installed the board and no ice building up. According to the internet the control board controls the defrost function on my model. Very happy. I'm still watching the freezer but I'm pretty sure I fixed my matter. Thanks for sending the right part and the video. Repair went well. Just take your time and go easy because everything involved is plastic. I didn't want to break any tabs I had to deal with.
Parts Used:
-
Robert from OWINGS MILLS, MD
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers
6 of 6 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
3-year-old refrigerator wouldn't cool, digital temp. control stopped working
The digital display numbers (0= off and 7=coldest setting) controlled by the ECB would continually be replaced by straight lines, and the refrigerator would stop cooling. I tried unplugging it for a while. After plugging it in again, it worked (the digital display came on, I set it to "4" and it reached the proper temp), but the problem occurred again the following day, and then it stopped cooling entirely. I ordered the ECB, and it arrived in 3 business days. I watched the installation instruction video, took my time, double-checked the vid a few times to make sure I was doing it correctly, and replaced the ECB by myself in less than an hour. The refrigerator has been running without problems for 3 weeks now. My fridge had a different light bulb configuration than the one in the video, but everything else was the same, and it was a simple repair.
Parts Used:
-
Rebecca from SAINT JOHN, IN
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Screw drivers
6 of 6 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer temperature goes down to -20*F before compressor stops but refrigerator side remains normal 38*F and compressor makes a grunting noise while running.
Unplug ref then remove lower(freezer) panel plus trays and thermistor’s cover/holder then remove the evaps cover. I found the evaps all frozen up. Cut and remove old thermistor, strip wires 1/2 inch then cut the new thermistor wires to length and strip 1/2 inch, use the enclosed insulated crimp type connector and put back everything in the reverse order. It works great afterwards.
Parts Used:
-
Aquilino O from VALLEJO, CA
-
Difficulty Level:Easy
-
Total Repair Time:1- 2 hours
-
Tools:Nutdriver, Screw drivers
6 of 6 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
refrigerator running all the time
Followed the video and installed the new Jazz board. The board cam in 1 piece which had to be separated into two pieces, but the scored area on the board made it less intimidating. At the same time I replaced the two incandescent lamps in the refrigerator area with LED lamps. Getting the housing for the control board apart was the most difficult part, installing the replacement board was a breeze.
Parts Used:
-
Steve from SOUTH ST PAUL, MN
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Screw drivers
6 of 7 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!