the hot and cold inlet valve assemblies were corroded and leaking out of the top
First I turned off the hot and cold water supply and removed the water lines from the back of the machine. I then unscrewed the 2 phillips head screws on the back of the washer for the cover. I slid the cover back and lifted it off the machine. Next, I unscrewed the mounting screws from each inlet valve assemble located on the back of the machine by the hose connections. I used pliers to pull the hose clamps back from the inlet valve, 1 at a time, then reconnected each hose and clamp on the new inlet valve. Once each hose was connected to the new inlet valve, I discarded the old inlet valves. I then re-attached each inlet valve. I placed the cover back on the machine and secured with the 2 screws, re-attached the water supply hoses to the hot and cold side and turned the hot and cold water supply back on. Everything successful, no leaks, and washing laundry again..........leak free!
Parts Used:
Inlet Valve Assembly Water Inlet Valve - Hot
  • Gregory from Collierville, TN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Replace inlet water valve assemblies
Our washer and dryer was stacked, and had to remove the dryer to access top of washer. This took 2 people and was not difficult due to the 168 lb weight of the dryer. Turned of water, pulled washer away from wall and disconnected the supply hoses. Removed the 2 screws holding the top, slipped it back and removed. Removed the 2 screws holding the inlet valve assembly, unplugged the wiring harness from the 3 solenoids, disconnected the 3 hoses from the hose bibs on the valves. Mounted new valve assembly, connected hoses making sure that clamps did not touch any other hoses, reconnected wiring harness, turned on water to check for any leaks, put top back on and tried washer out. Changing the valve assembly took a total of 15 minutes. Really simple. The You tube video very helpful in determining how to do the job.
Parts Used:
Inlet Valve Assembly Water Inlet Valve - Hot
  • James from Roper, NC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Cold water inlet would not shut off
Extremely easy--remove two screws in the back of washer connect elec. connections one at a time connect cold water lines one at a time and replace the two screws ion the back and you are done. Took longer to pull washer out from wall and push back than it did to replace part. Saved me $75.
Parts Used:
Inlet Valve Assembly
  • ronald from Corpus Christi, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Water leaks at both valves
Disconnect electric and remove top cover and remove connectors and hoses then the valves
Parts Used:
Inlet Valve Assembly Water Inlet Valve - Hot
  • Tommy from San Marcos, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers
Was this instruction helpful to you?
Thank you for voting!