Freezer would not keep running and the temperature was too warm.
Followed the sites instructions. Empty the bottom part of the freezer. Remove the screws. Move the panel out of the way. Easily remove the old part and replace with the new. Put the panel and screws back in place. The freezer works.
Parts Used:
Defrost Thermostat
  • Edmond from Carroll, NH
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Freezer ran alot, then temperture began to vary.
Watched video on Part Select which shows you how to replace the thermostat with several good pointers. Very easily done and now the freezer works great.
Parts Used:
Defrost Thermostat
  • John from Port Republic, VA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
lost cooling function.
Fan was locked up.
Parts Used:
Fan Motor
  • dennis from westminster, MD
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
Was this instruction helpful to you?
Thank you for voting!
Freezer freezes up; lower unit to warm
Replaced freezer defrost thermostat. Unit worked perfectly.
Parts Used:
Defrost Thermostat
  • David from Front Royal, VA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
Was this instruction helpful to you?
Thank you for voting!
freezer not staying cold enough
After researching other issues found on internet about same problem, decided to replace both thermostat and temperature control thermastat before going to the repairman way. I saw the videos given on this web site, ordered the parts and when they came in, unplugged freezer and started taking apart the back cover not sure what I would find. Turns out it was just that simple, unplugged the thermastat and unclipped it from the cooling fins, unplugged the temperature control switch and then plugged both units back in. The tricky part was coiling the temperature sensor ( not that tricky). I was done in about 45 minutes but that also included cleaning out and scrubbing the bottom and sides of freezer since I had everything out anyways. Started the freezer back up and took about 8 hours to freeze ice and other food at a setting of 4, where as before I had it set on 7 and was still not keeping the ice cream cold.
Parts Used:
Defrost Thermostat Temperature Control Thermostat
  • Kevin from Frisco, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the FFU20FC6AW4