Freezer would not keep running and the temperature was too warm.
Followed the sites instructions. Empty the bottom part of the freezer. Remove the screws. Move the panel out of the way. Easily remove the old part and replace with the new. Put the panel and screws back in place. The freezer works.
Parts Used:
Defrost Thermostat
  • Edmond from Carroll, NH
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Evaporator Fan Motor was making loud rattling sound.
Unplugged freezer from electrical socket. Removed lower trays from freezer. Removed sound proof stripping from sides of back panel. Removed upper, lower and side screws from back, lower panel using No. 2 phillips screwdriver. Disconnected motor wires from quick disconnect power supply. Removed motor bracket from freezer back using nut driver. Removed motor from bracket using same nut driver. Replaced motor and screws in bracket. reattached quick disconnect. Attached fan blade to motor making certain to push blade on shaft securely. Replaced bracket to freezer back. Replaced back cover. Replaced stripping. Plugged into power supply. Total time 15-20 minutes.
Parts Used:
Evaporator Fan Motor (115v) Evaporator Fan Blade
  • Richard from Clovis, NM
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Fan would not start occasionally
I unscrewed the screws that held the old fan on, disconnected the wiring harness and removed the old fan. I pulled the blades off the motor and put it on the new fan. One thing of note, the screw holes on the new fan weren't threaded. I assume this is by design, so I used the screws to thread the holes before installing it in the freezer. Once I did this, the rest of the installation was easy, just screw it back in and connect the wiring harness.
Parts Used:
Evaporator Fan Motor (115v)
  • Mike from Satellite Beach, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
freezer not cooling
inspected visible refrigeration lines for evidence of leaking, found nothing substantial that would cause concern, ordered capacitor and defrost thermostat simply because both are inexpensive parts and theoretically either could be causing the problem. Both parts were very simple to install especially since I am a semi-retired refrigeration man.
Parts Used:
Defrost Thermostat Run Capacitor
  • Shawnda from Union City, PA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Would not freeze or defrost
Unplug freezer let stand all night to defrost. Remove the tray cover which is located on the upper back area inside the freezer.( 3 twist fittings remove it ). Remove the upper stainless steel panel which is secured with 6 screws. This will drop down exposing the condenser. Note all the wires and fan will stay attached to the stainless steel panel, this panel will drop down no need to unplug anything. On the left upper side next to the condenser you will see the thermostat. Two color coded wires. Remove the thermostat and install the new one at the same location.
Parts Used:
Defrost Thermostat
  • RONALD from Sevierville, TN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
the compressor capacitor overheated
it was great. I ordered the capacitor for my frigidaire frig and it arrived
in 3 days. plugged in the part to the compressor and my frig has been
working ever since. I spent 3 minutes ordering the part and 30 seconds
attaching it to the frig. Easy, very easy. saved myself a 75 dollar repair
visit. thanks
Parts Used:
Run Capacitor
  • Bart from goldsboro, NC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
coils would freeze over not allowing air to circulate throughout freezer
replace thermostat and timer after defrosting and cleaning out freezer. I took less than 10 minutes and now freezer has a defrost cycle that eliminates frost buildup on the coils.
Parts Used:
DEFROST TIMER Defrost Thermostat
  • robert from royal oaks, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers, Socket set
Was this instruction helpful to you?
Thank you for voting!
Freezer was warm
I first noticed my ice cream getting soft. Then 2 days later the alarm went. I emptied the freezer, opened the panels and saw no frost. I saw that 99% of issues were resolved with a defrost timer and thermostat so I ordered those. I have to say the parts came quickly and they went in very easy. My freezer seems to be in the 1% category though. It's still not cooling even though I can measure the temperature at the front of the evaporator coil is cold but by the end of the coil it's almost room temperature. I think a repairman is called for.
Parts Used:
DEFROST TIMER
  • Charles from Macomb, MI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Original freezer gasket worn out
Removed old gasket by backing out screws around inner door panel. I did not remove the screws just loosened in order to remove old gasket. Starting from the top of the inner door panel I set the old gasket and squared off. Tightened top screws and worked the gasket in on the sides and tightened several of the screws on the sides then set the bottom of gasket in the door. Inserting the gasket in the bottom was the hardest part of the job. The overall job took less time than expected.
Parts Used:
Door Gasket
  • Laurin from Altamonte Springs, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Coils not Defrosting and stopped freezing
Upluged power pulled freezer out from wall removed the two screws that holds the defrost timer unpluged defrost timer pluged new timer in mounted new timer back with the two screws pluged freezer back in and job was complete. Freezer working fine.
Parts Used:
DEFROST TIMER
  • Joseph from Yulee, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?