Fridge started making a loud racket. Condenser Fan Blade then disintegrated to dust and pieces. The plastic had degraded significantly.
The repair itself total time was quick and easy. Since the original fan blade blew apart, it was only a matter of putting the new one on in it's place. This can be done by feeding the blade between the cowling and Condenser coil and applying pressure to get it on the shaft.
If your fan is still on the shaft, simply push it off and extract it the same way. Then place the new one on the shaft.
In my case, since the part would take a couple days to get, and I had food both in the fridge and the freezer, I removed and unplugged the Condenser Fan Motor and the cowling frame and temporarily spliced a small fan I had into the line for the condenser motor. This kept the fridge working long enough to get the replacement part.
Side note. Direction of airflow is towards the Compressor, and draws air across the Condenser coils.
Hope this helps someone. :)
If your fan is still on the shaft, simply push it off and extract it the same way. Then place the new one on the shaft.
In my case, since the part would take a couple days to get, and I had food both in the fridge and the freezer, I removed and unplugged the Condenser Fan Motor and the cowling frame and temporarily spliced a small fan I had into the line for the condenser motor. This kept the fridge working long enough to get the replacement part.
Side note. Direction of airflow is towards the Compressor, and draws air across the Condenser coils.
Hope this helps someone. :)
Parts Used:
-
Jack from WALLING, TN
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver, Socket set
4 of 7 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
One blade broke from condenser fan
The part i recieved, from parts select was a larger in circumfrence (<1/4) than the original. However i was not aware of this until after i treid to repair it.
I removed the broken fan from the condenser. This was very sipmle.
When i pluged the refridgerator back in to the outlet the fan tried to start up but soon began to make aloud noise, due to there not being enough clerance.
I removed the broken fan from the condenser. This was very sipmle.
When i pluged the refridgerator back in to the outlet the fan tried to start up but soon began to make aloud noise, due to there not being enough clerance.
Parts Used:
-
Chris from Lockport, NY
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
12 of 32 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer not cooling due to icing up of coil.
The timer in this older unit is clearly exposed at the back of the freezer underneath the freezer compartment. It is attached with two Phillips head screws. After the screws are removed, the timer can be unplugged and the new one plugged in. The new timer has an extra flange to allow it to be used on more than one model of freezer. In order to mount the timer in this unit, you have to remove the extra flange by carefully cutting it away from the timer body, in similar fashion to what's depicted in the online video. This will allow you to mount the new timer to the mounting plate using the two screws from the old timer.
Parts Used:
-
Thomas from GRANBURY, TX
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers
2 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Coils were freezing up. Defrost cycle not working
First unplug freezer, then disconnected wires from timer.
Removed 2 screws from bracket holding time to freezer.
Attached New part with screws. .The mounting bracket is now part of New time. Reattach wires.
I let coils defrost and then plugged it.
Removed 2 screws from bracket holding time to freezer.
Attached New part with screws. .The mounting bracket is now part of New time. Reattach wires.
I let coils defrost and then plugged it.
Parts Used:
-
Stirling from FORT WORTH, TX
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers
2 of 3 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Evaporator fan not working
Took off cover, unplugged wires, removed old motor, mounted new motor, remounted new motor and replaced cover.
Now need a new control board for same model.
Now need a new control board for same model.
Parts Used:
-
Randolph from Edwards, MS
-
Difficulty Level:Really Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Screw drivers, Socket set
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Evaporator Fan Motor burnt out because fan got stuck in frame wall during transportation
1st Turn off power. Removed freezer racks. Removed access panel to bottom back of freezer. Disconnect the wire harness to fan motor. Use 5/16 nut driver for removing fan motor from support. Removed fan blade from motor and put fan blade on the new fan motor. Bought new fan blades, but new fan blade would not work on new motor. Spring mount would fit on new fan blades, so I use the old one. Installed everything in reverse. Put everything back. Place thermometer in freezer. Freezer cooled down to -10F in 10 minutes. Great save on this one because I bought this freezer off of Facebook marketplace. Saved me $250. Good thing I know about fixing refrigeration equipment. Easy day.
Parts Used:
-
Dmitriyev from Ruther Glen, VA
-
Difficulty Level:Really Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver, Screw drivers
1 person
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
A set scew was ordered twice.
The first order arrived in a huge box and there was no scew to be found, the box had wholes in it. I was given a refund and told to order again.
The repair did not happen and the set screw which was actually recieved the second time was returned because it was the wrong size.
The repair did not happen and the set screw which was actually recieved the second time was returned because it was the wrong size.
Parts Used:
-
Susan from BRAINTREE, VT
-
Difficulty Level:Very Difficult
-
Total Repair Time:1- 2 hours
1 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Evaporator freezing up. Noticed Ice cream not frozen solid
Notice ice build up on the panel in front of the evaporator coil. Unplugged freezer and removed evaporator panel. Plugged unit back in and checked fan, coil "snap switch" and heater element, all seemed to check out good. Found defrost timer stuck in the freeze position, causing frost to accumulate over the evaporator. Manually rotated defrost timer to the 30min defrost cycle and system went into defrost. Ordered defrost timer and installed (part arrived in 3 days). Freezer works great again. Too bad I ended up throwing 400 dollars worth of meat away. the fix was very simple. Will definitely use PartSelect again. Thank you.
Parts Used:
-
Paul from Buffalo, MN
-
Difficulty Level:Really Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Screw drivers
0 of 1 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
loud noise fan blade broke,off balance
take 1/4 hex screws out clean out dust ,remove old fan blade replace with new install bolts .
Parts Used:
-
EDWIN from ELWOOD, IN
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver
0 of 1 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The new motor mount screw holes were not threaded.
I had to tap the screw holes with a 8/32 tap so that the screws would not bind.
Parts Used:
-
Greg from henrico, VA
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:1- 2 hours
-
Tools:Nutdriver, Socket set
1 of 5 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
No problems
I had no problems. Screws arrived sooner than expected. It was a very simple installation. Very pleased with both the product and service.
Parts Used:
-
Nancy from LEHIGH ACRES, FL
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Wrench (Adjustable)
2 of 9 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
When I was ready to instal fan motor, I noticed that there was no thread where I was supposed to screw in the bolts
When i found out there was no thread in brace where bolts were supposed to screw in, I panicked. I thought I would have to send part back or go to a machine shop to make a thread. I called a friend for help and he told me the bolts would make the thread if I just screwed them in. Sure enough, the bolts made the thread and then I just proceeded to instal motor and put refrigerator back together. It was simple.
Parts Used:
-
hector from los fresnos, TX
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers, Wrench set
Was this instruction helpful to you?
Thank you for voting!
condenser fan stop working
Replaced fan. I ordered the fan and received it the following.(-:
Parts Used:
-
George from Gilroy, CA
-
Difficulty Level:Really Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver, Screw drivers, Socket set
Was this instruction helpful to you?
Thank you for voting!
Freezer was warm
I first noticed my ice cream getting soft. Then 2 days later the alarm went. I emptied the freezer, opened the panels and saw no frost. I saw that 99% of issues were resolved with a defrost timer and thermostat so I ordered those. I have to say the parts came quickly and they went in very easy. My freezer seems to be in the 1% category though. It's still not cooling even though I can measure the temperature at the front of the evaporator coil is cold but by the end of the coil it's almost room temperature. I think a repairman is called for.
Parts Used:
-
Charles from Macomb, MI
-
Difficulty Level:Really Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Evaporator Fan Motor was making loud rattling sound.
Unplugged freezer from electrical socket. Removed lower trays from freezer. Removed sound proof stripping from sides of back panel. Removed upper, lower and side screws from back, lower panel using No. 2 phillips screwdriver. Disconnected motor wires from quick disconnect power supply. Removed motor bracket from freezer back using nut driver. Removed motor from bracket using same nut driver. Replaced motor and screws in bracket. reattached quick disconnect. Attached fan blade to motor making certain to push blade on shaft securely. Replaced bracket to freezer back. Replaced back cover. Replaced stripping. Plugged into power supply. Total time 15-20 minutes.
Parts Used:
-
Richard from Clovis, NM
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver, Screw drivers
Was this instruction helpful to you?