No ice from door, but did have water
I got the wrong switch before so just need to put the right 1 in. Super easy, pop off old, plug in new, click back into place. Done. REALLY REALLY EASY for anyone to do
Parts Used:
SWITCH LIGHT FZ
  • Rich from san marcos, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
4 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Squeky Evaporator Fan
I made my wife fix it.
Parts Used:
Evaporator Fan Grommet - Grey
  • Douglas from LAFAYETTE, LA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator stopped working / cooling
Our refrigerator stopped working/cooling. Searched Youtube for troubleshooting solutions and found several helpful videos. After following the instructions from the various videos I determined that the main controller board was bad. Ordered the part from PartSelect, received it in timely manner, installed the part following the instructions provided from videos and the refrigerator started up right away. Gave it 24 hours before to make sure it was going to cool down and hold proper temperatures then put it back in use.

We are really happy not to be buying a new refrigerator.
Parts Used:
Board Assembly Main Control
  • Donald from MARIETTA, GA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice Maker Not Making Ice
My GE SideBySide fridge stopped making ice. The green LED light on the icemaker was not blinking. The water dispenser worked fine. Fridge is only 5 years old. Freezer temp set at 7 degrees...fridge at 37 degrees. I have been using these temps since new. GE hotline suggested freezer temp should be at zero degrees. That did not work. Second call suggested an airflow issue within the freezer...there should be 1 inch space between food and back wall. Still no ice. The water valve looks to be the issue. I ordered it and got it in 2 days. Valve is in the back bottom, refridgerator side. Push the white collars around the water hoses...Then pull the hoses out. An adjustable wrench removes the nut for the inlet hose. Disconnect 2 electrical plugs. Be sure to push the water hoses fully into the new valve. I pulled the white collars out a bit to insure a tight fit. I was surprised at how simple this was to install. As it turns out, I was still getting no ice. I ordered a new ice maker and now I'm getting ice. The icemaker was EVEN EASIER to install.
Parts Used:
WATER VALVE WITH GUARD
  • Kevin from Alhambra, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Wrench (Adjustable)
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Door flapper would not self-close
I replaced the original solenoid, which had rusted into one solid piece. OMG how easy was that!
Parts Used:
Dispenser Door Solenoid Assembly
  • Stephen from Los Angeles, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice Maker Door flap would not close all the way
Went on this site, found out many others like me had the flap door stuck open problem, it would not shut after you went for ice. I needed a new solenoid that opens when the ice is dispenced and closes afterwards not allowing the warm ambient air to come up the shoot which frosts the ice and melts it. It shipped QUICK and now I have a working ice maker dispenser from the outside. Its been 2 YEARS of opening the door and reaching into the ice maker bin for ice! Thanks PartSelect
Parts Used:
Dispenser Door Solenoid Assembly
  • Edward N from Boyds, MD
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator not defrosting, ice tray clogging up in ice tray, refrigerator making loud humming noise, and compressed running all the time.
First, turn off power - since I did not want to pull the refrigerator out on my wood floor I tripped the circuit breaker to that circuit and opened door to make sure interior light was off (ensuring power was off). This unit has a bottom freezer, I took out all shelves, ice maker and all parts in the way of accessing back of interior of freezer section. Removed back plastic section by removing one screw in middle top of back panel and prying it out. This was a bit difficult as it was in there a bit tight but once the plastic warmed up it pulled out ok. This revealed the compressor section and temp sensor that was attached to the copper coils with of all things - a zip tie! In pictures of this that I looked at on various web sites the sensor was on a metal bracket attached to the coil so it made me wonder if tf the factory took a shortcut? I cut the old sensor wire, stripped the two wires 1/2", and connected them to the new sensor wire with butt connectors, I put some silicone into the ends of the butt connectors to prevent moisture from entering into connectors and wrapped the connection in black electrical tape. I then "attached" the sensor to the coil using a zip tie, put the plastic back piece back on, inserted everything I took out and put power back to refrigerator. It's been 3 days and temp of refrigerator is stable, ice maker not clogging up, and compressor not running all the time! So far so good.
Parts Used:
Temperature Sensor
  • Mark from ROSEMOUNT, MN
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Replace water filter with bypass plug - filter is redundant with home osmosis system
If you have a reverse osmosis system for filtered water system in your home that also feeds the refrigerator, using another water filter in the refrigerator is redundant, so GE makes a Water filter Bypass Cap that allows you to run using the already filtered water without needing to expensive water filter. FIRST - using a phillips screw driver remove the toe kick plate at the bottom front of the refrigerator - two screws - one on each side of the plate that extends the entire width of the refrigerator. SECOND - Locate the water line (should be right in front) and the valve to turn off the water. Turn valve clockwise (right) until completely closed. Then test by attempting to fill a glass with water using the dispenser on the door. If any water continues to come out, continue turning the valve (without forcing it) clockwise until it has been turned as much as possible. If water still comes from dispenser, locate the source of the water line - most likely from under the kitchen sink. There should be another valve under the sink, or simply turn off (turn the cold water valve clockwise) until water cold water completely turned off. Test again as required. THIRD - clear the top right hand back shelf directly under the water filter screwed into the ceiling of the refrigerator in the rear top right side of the refrigerator. Place a small towel under the water filter, and slowly turn the filter 1/4 turn clockwise without using force. Continue turning until the full 1/4 turn is complete and the filter will drop down without pulling. Place the old filter upside down in the sink, thereby allowing the filter to drain any water present in the filter. FOURTH - remove the filter plug from package, notice notches in top of plug that align with gaps in the area where a filter would typically be screwed into the filter location in the ceiling above the top right shelf in the refrigerator. After aligning notches in the bypass plug with gaps in the screw mechanism, carefully turn the bypass plug 1/4 turn counter- clockwise - at which time the bypass plug should be firmly installed. FIFTH - Reverse step SECOND, and turn valve Counter-Clockwise until valve is completely open. Test to ensure no water is leaking from the Bypass Plug. SIXTH - Finally reverse step FIRST by reattaching the toe kick plate using the two phillips screws removed in Step FIRST. NOTE: The Bypass Plug is quite inexpensive, but after adding shipping from Canada - the cost is about the same as purchasing a new filter for the refrigerator. :-(
Parts Used:
Refrigerator Bypass
  • Fred from LA QUINTA, CA
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The ice flapper would not go close .
remove the front of were the ice and water comes out
then un scerw 4 scerw and the solenoid slides out unhook the wires and put the new one in
Parts Used:
Dispenser Door Solenoid Assembly
  • Shelly from WATERLOO, IN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Yearly replacement of filter
Moved stuff out of my way on the top shelf, reached in and turned old filter to remove. Filled new filter with water, lined up and turned to lock in place. Whew, never thought I would get that job done. :-)
Parts Used:
Refrigerator Ice and Water Filter
  • Robert from Myrtle Beach, SC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Defroster fan burned up
First I removed the ice tray rack lifting it out of the way to reach the back cover of the fan. Then, the whole back inside panel had to be removed. Two screws removed the fan and bracket from the freezer unit. The missing bumper lid just snapped into place. Replaced everything in reverse order. Pretty easy job.
Parts Used:
Lid Bumper
  • Peter M. from Lincoln Park, NJ
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers, Socket set
3 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice flap in door wouldn't close
Take the face (the part with the buttons on the outside) off, disconnect wired connectors (three), take the screws out of the part behind that (4), and then find the solenoid value (on the right). It's attached with three screws. Mine was rusted beyond belief. I knew this was the problem, ordered a new solenoid valve, put it back in place with three screws (use new screws that fit, not the old rusty ones if possible). When testing, make sure you give the flap a couple of seconds to close. There is a delay, and I initially wasn't patient enough so I had to disassemble and assemble an extra time because of this.

Simply put: If your solenoid value is rusted and the value won't operate smoothly, order the part and install it. This is as easy as any repair could be.
Parts Used:
Dispenser Door Solenoid Assembly
  • Benjamin from Goldsboro, NC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
the cecular door for the ice was geting stuck opened
with a small screwdriver push in tabs in upword movement to remove the face cover for the three botons of ice crushed ice and water .
once removed remove four screw to take out the circular door .
solinoid plunger will be atached to the door and it has to screws holding the solinoid .
instolation is the oposit steps of removing the part
Parts Used:
Dispenser Door Solenoid Assembly
  • john from st aug, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Socket set
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer frosting up around ice dispenser chute.
Ordered new solenoid so the flap would close. That did the trick.
Parts Used:
Dispenser Door Solenoid Assembly
  • Bryan from Fairfax, VA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
2 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Light would no longer turn on
I watched the video online, followed the instructions and within minutes had the part installed. The frig light was working once again! I will say the original switch was very snug and I had to do some very minor scraping of the plastic to get the new part to slide in.
Parts Used:
LIGHT SWITCH
  • paypal_shipping_address from Ripon, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers
3 of 6 people found this instruction helpful.
Was this instruction helpful to you?