The compressor would try to start,but would not.
I pulled the whole unit(condenser&overload relay)
with my hand & disconnected the wire connected
to it & Replaced it with the new one.Peace of cake.
Parts Used:
Compressor Start Device and Capacitor
  • Alfred from Port Charlotte, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
20 of 24 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Steady water leak.
It's good to note, first, that the dual water valve on Amana fridges are notorious for cracking and leaking, either due to the fridge being left in the cold (the water inside the valve freezes and expands, cracking the water valve) or from issues related to shipping. Read the reviews, here - it's a common issue, but easy and cheap to fix yourself. Here's my steps. I first turned off the water source to fridge by closing the correct valve. Next, I unplugged the fridge from electrical and from the water source line. When looking at the back of the fridge, I unscrewed the bottom left cover plate from the fridge body. After unscrewing and removing the plate, I made sure to note which lines came from which areas of the fridge and where the lines ended up at the dual water valve, and how they were routed through the plate and into the valve. The way this fridge is setup, the water source line screws into a main line that heads to the top of the fridge where the water filter is (like a "line in"). There's another line that heads back down to the bottom of the fridge (line out). The "line out" inserts into the outside plug of the dual water valve. The two lines coming out of the dual water valve are different sizes. Make sure to note which line goes to the icemaker and which line goes to the water dispenser inside the fridge. Once I knew which lines needed to go where, I grabbed my empty bucket, pulled the water lines out of the dual water valve with some pliers, and emptied the water into the bucket. After cleaning up any water splatter with my dry towels, I unscrewed the dual water valve from the plate. Once the old dual water valve was removed, I replaced it with the new valve and screwed it back into the plate. I cut off just a bit of the water line ends that were damaged due to pulling with the pliers, and then inserted them back into the correct spots on the dual water valve. I screwed the plate back into the fridge, reconnected the water source line (make sure to use some kind of water sealer tape or putty), plugged the fridge back into the electrical socket, turned the water source valve back on, and waited for leaks. No leaks! Once I was convinced there weren't any leaks, I had to bleed the water lines for about 20-30 minutes (it takes FOREVER...) by putting my bucket under the water dispenser inside the fridge and holding the water button for what seemed like an eternity - until the water was streaming steadily out of the dispenser. Voila! Good as new! Keep in mind that I didn't go through ALL the minute parts of each step - that would take too long. I'm believing that you'll be perceptive enough to catch the small things like looking at how the lines are routed into the dual water valve and where things are screwed into. Use your BRAIN, and you'll be fine. :-)
Parts Used:
Refrigerator Dual Water Valve
  • Ben from Plainwell, MI
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers, Socket set
19 of 22 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator wouldn't get cold enough.
Freezer would get cold at bottom and some of the refrigerator. Took of freezer back panel and located freezer fan. Took a meter and saw power was getting to it, but not working. Removed fan and replaced with new on, working like a charm. Cold air was not circulating enough throughout the unit because fan was not working. It was not the thermostat or adapter control.
Parts Used:
Freezer Evaporator Fan Motor 115v 60hz
  • Ty from Wentzville, MO
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
20 of 26 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
evaporator coil covered in ice
Remove bottom panel in freezer side to get access to the coil.Remove old heater element and defrost thermostat.Installed new hearter and thermostat.Screw back bottom panel re-start frige.
Parts Used:
Defrost Thermostat Defrost Heater
  • Anthony from Waukegan, IL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers
18 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
No Problem, time to replace water filter
Turned the old one to unseat and replaced with a new one in the reverse order.
Parts Used:
Refrigerator Water Filter
  • Ralph from Longmont, CO
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
18 of 24 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Our refrigerator was too cold as the thermistor seems to have gone
It was great. We replaced the thermistor A little difficult to get to the thermistor but once we found it five minutes. My refrigerator seems happy but we will monitor it and see.
Parts Used:
Thermistor
  • Ellen from SUN CITY WEST, AZ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
19 of 29 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
no cooling either fridge or freezer
Refrigerator was stored for about 2 years and we picked it up when the owner decided to move into an apartment and no longer needed to unit (lost home to foreclosure). Brought the unit home and it worked great for about 3 days. On the third day my wife noticed a slight electrical burning smell. I did also and quickly emptied the unit and hoped for the best. The unit did indeed stop working. I fancy myself a do it myselfer but I would normally not go near electricity but thought what the heck it was free if i ruin it I would give it away. After a little research i found Partselect and they had a great design and a few stories that sounded similar so i pulled the relay capacitor for the compressor and sure enough the unit showed burn marks where the unit had shorted out. Maybe a bug got in there or water, dirt but I ordered the part. I arrived in two days which was great. I installed the part and plug the unit in and crossed my fingers. Very happily the unit clicked on and has been running great ever since. thanks Partselect, while I may not be one of your big customers I will refer anyone with appliance issues to your site first.
Parts Used:
Compressor Start Device and Capacitor
  • chad from stockton, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers
15 of 17 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
fridge wasn't getting cold
Cut wires and removed old thermosat. Spliced new thermostat wires into exsiting wire. Put it all back together. Works great now. Thanks for all the help. Your site is great. Only problem we had was getting the part from FED EX. Took over 2 weeks had to go pick up the part ourselfs.
Parts Used:
Defrost Thermostat
  • deanna from oak run, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
15 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Old Icemaker noisy and stopped making Ice
The old icemaker had a bad motor and would stall in the fill cycle causing my kitchen to flood on occasion.

The new one was so quiet, I thought it didn't work!

Anyway, one nutdriver and 5 minutes and I had the new one in there... It is so quiet, and I always have plenty of ice now!!!

Thanks!!!
Parts Used:
Replacement Ice Maker
  • Daniel from Rhinelander, WI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
18 of 28 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer was not staying cold enugh for ice maker to work. Discovered fan was not working to cool condensor. Fan motor would only run if manually turned.
Unplugged refrigerator. Removed lower back access panels and panel running up the back of refrigerator. Removed and disconnected old fan. Removed old fan motor from mounting bracket. Removed fan blade from old fan motor and placed on new fan motor. Connected new fan motor to power supply. Tested. Reinstalled.
Parts Used:
Refrigerator Condenser Fan Motor Kit
  • David from Cedarville, OH
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Screw drivers, Socket set
14 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water head filter was leaking
Followed the first set of instructions from the parts select website. It worked perfectly. Just note that the way to remove the "blue" tube is by pushing down on the fitting and then pull the tube out. Be careful with the styrofoam piece around the hole for the tubes as it can crumble around the edges.
Parts Used:
Refrigerator Water Filter Head
  • Lee from Yarmouth, ME
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Wrench (Adjustable)
17 of 26 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
No ice or water at door
Removed the filter from inside the ref then disconneted the water line to filter and to ice maker on blue line just push line down then up to remove. Then pull whole assb. thru refreg. and install new one. very easy 2nd time mine went bad 1st time it coast almost $300.00 this time less than $50.00. Take your time and its fool proof.
Parts Used:
Refrigerator Water Filter Head
  • Harvey O. from Venice, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers, Wrench (Adjustable)
19 of 32 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
ice wheel was broken
remove the bin from the freezer, there are 2 tabs on the lower front cover that pop off and you just pull the entire front cover off. there are 4 nuts that hold the blade cover which you can use the 7in1 with the insert removed.. i believe it's 5/16". remove the cover and the tumbler assembly pops out of the tray.
remove the nut with a set of pliers and lay it out on the table in order.
install is reverse of removal. make sure you get all the washers in the correct location when assembling. don't tighten the nut too tight or it will bind the rotating assembly.

enjoy retrieving ice from the door again!
Parts Used:
Refrigerator Crushed Ice Wheel
  • rosemarie from duarte, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers
14 of 17 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
fridge and freezer quit working
noticed the fridge and frezzer were not cold one day.i got on google and typed in the problem and found out the the relay goes bad rather often. was an easy fix. found the parts here on partselect and recieved in with in 2 days of ordering. pulled the old part out put new part in and plugged fridge in and was back up and running with in minutes..thank you partselect....
Parts Used:
Compressor Start Device and Capacitor
  • mike from galt, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
12 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water dispenser got stuck on one function, couldn't get water to work
Removed two screws and took off water dispenser front panel. Unplugged wires to old control board and removed it from brackets holding it to inside of dispenser panel. Aligned and pushed new control (with care to only touch the outside edges of board...cannot touch circuitry which will permanently damage it). Was tricky aligning the board and snapping it back on, but finally got it in place. Repositioned dispenser panel and reattached two screws.
Second problem was the Chute and chute seal had broken off from the hinge chute so it wouldn't open or close when dispensing ice. Was pretty tricky to realign the chute seal to the hinge, but with some paitence and manipulation, was able to reconnect them.
I am REALLY impressed with the detailed drawings I found on PartSelect.com's website. Without these drawings it would have been difficult for me (my husband and son put the parts in, I did the ordering) to know what parts to order. Service was EXCELLENT. I would definitely do business with this company again. Great work!
Parts Used:
Ice Chute Door Insulation Dispenser Electronic Control Board Ice Chute Seal Ice Chute Door
  • Janet from Edmonds, WA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
13 of 17 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!