Water will not dispense and the refrigerator drawers were freezing our foods and vegetables.
It was a simple remove and replace. The new part fits directly in place of the old part. Its a pain to remove the light but once you get the light out the job is simple. The light must be pried out gently. It is snapped in place toward the air inlet cover and needs to be pried loose. Once the light is out there are 4 screws holding the air inlet cover in place. Remove the 4 screws and unfasten the wiring harness. Once the screws and wiring harness are disconnected remove the old part. Reinstall the new part in reverse order.
Parts Used:
-
Jeff from Manteca, CA
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Screw drivers
5 of 5 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Unit had stopped making ice
Ordered the icemaker replacement. unplugged the unit, followed the simple instructions and got it done in less than 30 minutes. It did take a LONG time to start making ice. But it's working now.
Parts Used:
-
Ron from ORANGE, CA
-
Difficulty Level:Really Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver, Screw drivers
5 of 5 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker inlet tube was freezing up, and eventually the icemaker overfilled and completely froze up
After lots of research online, i narrowed my problem down to be the double outlet water valve, behind the fridge. My biggest problem was getting the refridgerator out of its spot, but after that it was pretty simple to change. I took the cover off the bottom, in the back of the fridge, then i removed the inlet waterline (after i turned off the water supply to the fridge). After that i removed the screw that holds the valve to the framework. Now i pulled off the two other waterlines from the old valve and moved them, one at a time, over to the new valve, along with the wire harness. The rest of the instalation was reverse order. Simple fix that im glad i didn't pay an expert to do!
Parts Used:
-
Jake from Brainerd, MN
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Pliers, Screw drivers, Wrench (Adjustable)
5 of 5 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The grill flew off going down the freeway.
I took the part out of the package and placed it in the recessed water dispenser/ice maker cavity. Done!
Parts Used:
-
Mark from Ramona, CA
-
Difficulty Level:Really Easy
-
Total Repair Time:1- 2 hours
7 of 11 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Would not cool top or bottom
Everything looked to be working but the compressor. As a pro checked every thing came down to a relay on the main board.
Just removed cover from back top left. marked and removed all wires. removed old board and installed new board very easy. Must read paper sent with it,
you may need to cut wires on some models.
Just removed cover from back top left. marked and removed all wires. removed old board and installed new board very easy. Must read paper sent with it,
you may need to cut wires on some models.
Parts Used:
-
David from White Pine, TN
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver
5 of 6 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker solenoid failure
several times I had to remove the ice maker door solenoid due to it sticking. I ordered a new one from parts select. Problem solved!!!
Parts Used:
-
Robert from Mahopac, NY
-
Difficulty Level:Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Screw drivers
5 of 6 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Frost In Frezer Compartment Where Chute Meets Ice Cube Maker
Removed front panel (using small screw driver) by popping it out, disconnected wire from solenoid, removed solenoid which was rusted, 3 small philip head screws held it in place insereted new solenoid,connected wire snapped front panel back in. Clapper valve closes tightly and no frost in frezzer, saved my self a bunch of money.
Parts Used:
-
Anthony from Miramar Beach, FL
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers
10 of 21 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Was not getting water to the door.
Moved refrigerator out from wall, unplugged from electric, removed plate at bottom back with 1/4 nut driver, turned incoming water valve off, disconnected water line from water valve on refrigerator, removed mounting screw, remove water lines from valve and electrical plugs, set old valve aside and replace with new valve, reconnecting water lines and electrical plugs then remount bracket, reconnect water line from source, open water valve and check for leaks, replugged refrigerator and depressed the door button to check to see if working. It worked and there was not any leaks. Replaced back plate and placed refrigerator against wall. Job completed.
Parts Used:
-
nancy from Mt. Washington, KY
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver, Wrench set
5 of 6 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice Maker would not fill.
Was concerned that new icemaker was quite a bit different than the one we were replacing. Called GE to confirm it was correct.
Went ahead and installed the unit, using the supplied electric cable adapter.
A little difficult to deal with the extra cable, but everything worked OK and it's making ice normally.
Went ahead and installed the unit, using the supplied electric cable adapter.
A little difficult to deal with the extra cable, but everything worked OK and it's making ice normally.
Parts Used:
-
Charles from Keller, TX
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers
5 of 6 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker door didn't open and close properly
I removed the outer plate by sticking a very small screwdriver in the small holes at the bottom of the plate and pulling the plate toward me.
I then removed the 4 screws from the internal plate and pulled the plate toward me.
Then I romoved the 3 screws holding the old solenoid and unplugged it.
Next I put the new solenoid in place and replaced the three screws.
Finally I plugged in the solenoid and replaced the internal and external plates.
I then removed the 4 screws from the internal plate and pulled the plate toward me.
Then I romoved the 3 screws holding the old solenoid and unplugged it.
Next I put the new solenoid in place and replaced the three screws.
Finally I plugged in the solenoid and replaced the internal and external plates.
Parts Used:
-
M Alan from Lebanon, TN
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers
5 of 6 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Dispenser flap for ice not closing. no water from dispenser was coming out.
Water line 5/16inch was severed, under refrigerator. Used union connector to join line. Dispenser plate removed using allen key to unsnap plate ,from under the plate itself. Removed screws holding solenoid valve and removed the plug from circuit board connected to solenoid. Installed new solenoid valve. Put flapper back in place, and made sure spring on left side of flapper is reattached to the opening on the flapper. This corrected all problems. Caution, keep an eye on spring that it remains in place.
Parts Used:
-
Bart from Whitestone, NY
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver, Screw drivers
8 of 15 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer stayed cold but Fridge got warm every 3 weeks
Unplug the fridge, then:
1) Remove food and shelves from freezer
2) Remove rear panel from inside freezer (panel that covers the evaporator coils)
3)Stare at all the ice covering the coils for 10 seconds!
4) Plug the drain hole in the bottom left side of the freezer (cork or plug made from rolled up paper towel), and place a big towel in the bottom of the freezer compartment to absorb the melting ice
5) Plug in a table fan and leave it blowing into the freezer compartment, at the iced-over coils. Come back in 30 minutes.
6) Ice should be all melted. Place the wet towel in a bucket.
7) Remove the little clip attached to the green wire from the top of the panel., and then remove the two top screws on either side of the panel covering the coils. Take out the panel.
8) Removed the two screws that hold the heater element in place at the bottom of the coils. Pull the element out about 3 inches and disconnected the two wires.
9) Connect the wires to the new heater element, and screw it back into place. Put panel back, shelves in, turn fridge on. Fixed
I ordered the defrost heater and replaced that, also ordered the defrost thermostat but the old one looked fine so I did not replace that. Fridge and freezer have been working great, no more icing problems.
Thank You PartSelect!
1) Remove food and shelves from freezer
2) Remove rear panel from inside freezer (panel that covers the evaporator coils)
3)Stare at all the ice covering the coils for 10 seconds!
4) Plug the drain hole in the bottom left side of the freezer (cork or plug made from rolled up paper towel), and place a big towel in the bottom of the freezer compartment to absorb the melting ice
5) Plug in a table fan and leave it blowing into the freezer compartment, at the iced-over coils. Come back in 30 minutes.
6) Ice should be all melted. Place the wet towel in a bucket.
7) Remove the little clip attached to the green wire from the top of the panel., and then remove the two top screws on either side of the panel covering the coils. Take out the panel.
8) Removed the two screws that hold the heater element in place at the bottom of the coils. Pull the element out about 3 inches and disconnected the two wires.
9) Connect the wires to the new heater element, and screw it back into place. Put panel back, shelves in, turn fridge on. Fixed
I ordered the defrost heater and replaced that, also ordered the defrost thermostat but the old one looked fine so I did not replace that. Fridge and freezer have been working great, no more icing problems.
Thank You PartSelect!
Parts Used:
-
Mike from Seaford, NY
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Screw drivers
5 of 6 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water not dispensing
Background: My refrigerator was part of the class action law suit back in 2006. As a result both doors, the auger in the ice maker and a heating element in the freezer were all replaced.
Problem this time: Water was not dispensing.
Solution: Replaced the double outlet water valve in the back lower left portion of the refergerator. Water was coming into it from the water filter hose, but not coming out of it when the water dispenser in the front was engaged.
Further, I found that the coils in the back of the freezer were iced up and I therefore defrosted them with a heater. Thus, the original problem encountered with the law suit, did not get fixed by simply replacing the doors. That problem is still there. I think the defroster/heating element in the freezer is again not working.
However, I do now have water flowing again and the installation was, as others have described, very easy. Thanks for the online help.
Problem this time: Water was not dispensing.
Solution: Replaced the double outlet water valve in the back lower left portion of the refergerator. Water was coming into it from the water filter hose, but not coming out of it when the water dispenser in the front was engaged.
Further, I found that the coils in the back of the freezer were iced up and I therefore defrosted them with a heater. Thus, the original problem encountered with the law suit, did not get fixed by simply replacing the doors. That problem is still there. I think the defroster/heating element in the freezer is again not working.
However, I do now have water flowing again and the installation was, as others have described, very easy. Thanks for the online help.
Parts Used:
-
Bob J from Platte City, MO
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver
5 of 6 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
broken auger in the bucket assembly.
I ordered the wrong part, the ice maker assembly, because your diagram was not marked properly. I returned the part and you credited my account. Thanks. Ordered the new bucket. It worked fine. Now I have ice and crushed Ice whenever I want. Thanks.
p.s. I didnt use any tools, but to satisfy you I select nut driver.
p.s. I didnt use any tools, but to satisfy you I select nut driver.
Parts Used:
-
Chip from Mandeville, LA
-
Difficulty Level:Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Nutdriver
6 of 9 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
cold water dispenser would not stop running
Turn off the water.
Unplug the refrigerator
Take the back off of the refrigerator
use socket wrenchs to undo and take off the water valve in the lower left corner of refrigerator.
Pull out and disconnect electrical connections
Pull out the 2 water tubes one for ice and 1 for water-white is water and black is ice.
install the new valve and connect the water and ice back in the new unit
connect the two power cords and reattach unit to the frame Turn water on and check for leaks.
If no leaks put back on refrigerator and plug in.
Wait 30 min to an hour for water to begin to flow back into the unit.
Unplug the refrigerator
Take the back off of the refrigerator
use socket wrenchs to undo and take off the water valve in the lower left corner of refrigerator.
Pull out and disconnect electrical connections
Pull out the 2 water tubes one for ice and 1 for water-white is water and black is ice.
install the new valve and connect the water and ice back in the new unit
connect the two power cords and reattach unit to the frame Turn water on and check for leaks.
If no leaks put back on refrigerator and plug in.
Wait 30 min to an hour for water to begin to flow back into the unit.
Parts Used:
-
Robert from Summer feild, FL
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Socket set
5 of 6 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!