25360303613 Kenmore Refrigerator - Instructions
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
no heat when drying
-
Glen from North Tonawanda, NY
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver
Was this instruction helpful to you?
Thank you for voting!
Original plastic hinge cracked across the middle
Removed 2 hex screws & old hinge, placed new hinge on cabinet & found that it didn't fit; one hole was about 1/8" off. Had to drill a new hole in cabinet top in order to attach new hinge. Hinge works fine now. I'm glad to find the hinge is metal; original one was plastic.
Parts Used:
-
Al from Sarver, PA
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver
Was this instruction helpful to you?
Thank you for voting!
has lights,no fan or compressor
jump thermostat,fan and compressor came on, ordered thermo from this excllent parts supplier, part came in 4 days later, it was exact replacement, works exactly right!
Parts Used:
-
francis from arlington, WA
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver
Was this instruction helpful to you?
Thank you for voting!
Refrigerator door sagged, had to push the door to close it.
Used wood blocks to raise the door off the lower hinge bracket then unscrewed the suspect hinge. Cut a small shim, two layers of soda can, to place under the lower edge of the new hinge bracket and doubled the washers by using the old one to ensure I had adequate clearance for the door. After a little silicone lube I installed the new hinge bracket. All better now.
Parts Used:
-
Michael Jude from Saint Martinville, LA
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver
Was this instruction helpful to you?
Thank you for voting!