Models > 25338652993 > Instructions

25338652993 Kenmore Refrigerator - Instructions

All Instructions for the 25338652993
31 - 45 of 306
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
ice maker would not make ice
un plug fridge. removed ice maker from fridge. loosen 2 mounting screws. lift unit in slots to get over heads of screws. unplug wire harness. remove cover. remove 3 screws from control housing. remove 2 motor mounting screws. unplug motor wires from switches w/needle nose. installation is the reverse. plug in fridge turn on icemaker. takes 10 to 15 min to start to cycle.
easy and cheaper than new fridge or ice maker
Parts Used:
Replacement Ice Maker
  • paul from traer, IA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
16 of 22 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator was not cooling
This was a simple job. Raised the flap in the back that houses the compressor, removed the wire that holds the relay, pulled out the old relay and pushed the new one on. Replaced wire holder and that was it. Plugged it frig and freezer is at zero and lower compartment at 35. As easy as brushing your teeth!
Parts Used:
Run Capacitor
  • Vicki from Johnson City, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
16 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator quit running
I located the part that was the culprit as it had buzzed very much before quitting. This is an easy removal as the part is in a two prong jack and just needs to be carefully removed with the new part inserted back in the jack provided. The refrigerator works fine now, but the run capacitor will still buzz on start up of the compressor. I do hope this is normal in this model? anyway it runs fine mow. Thank you.
Parts Used:
Run Capacitor
  • Frederic from Daytona Beach, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
22 of 42 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fridge side warm. Freezer was ok.
Popped off the front plastic cover on the bottom of the fridge, under the doors. Two screws held the defrost timer on under the front side of fridge (below freezer door). You can't really see the timer except for the adjustment knob that is accessible through a hole. Once the screws are removed, disconnect the wire plug and remove and replaced unit. Works fine ever since.
Parts Used:
Defrost Timer - 60Hz 120V
  • Doug from Folsom, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
13 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
frezer not staying cold enough to freze newly added product
took the shelves out, unscrewed the rear panel,unpluged the thermistat and uncliped it from the line.Replaced with new thermistat in the reverse order. Before turning the unit back on,allowed the coils to defrost.All of the process was shown in your vidio that I was able to view while ordering the part. Thank you
Parts Used:
Defrost Thermostat
  • Robert H. from Grand Blanc, MI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
13 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fan Noise
took cover off inside freezer control . removed old fan and unpluged wire harness plugged new one up and fastened back in place and put control cover back on.
Parts Used:
Evaporator Fan Motor Kit
  • Kenneth from Springfield,, TN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
11 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Icemaker Wasnt Making Ice
After unplugging electric cord and turning off water at wall, I then removed the two screws that secured the valve to the refrigerator. I then removed the water connections to the valve and removed a short portion of the hose going to the icemaker. I then installed the connection pieces provided package and reversed the procedures to install the new part. It was easier than I thought it would be.
Parts Used:
Single Outler Water Valve Kit
  • ERIC from SAN ANTONIO, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers
11 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker was not making ice
I replaced the solenoid first because the ice maker was not getting water. After replacing the solenoid valve, I waited about 1/2 an hour, still no water. So, I ordered a replacement ice maker. I then installed the replacement ice maker, waited a 1/2 an hour, still no water. Then, I waited overnight. Yeah, ice! WORD OF ADVICE. WAIT OVERNIGHT TO SEE IF THE ICE MAKER CREATES ICE. Not sure how long a cycle takes, but it's longer than you would think. Hope your installation is a success!
Parts Used:
Replacement Ice Maker
  • Jeffrey from Indianapolis, IN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
9 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer starter acumulating lots of ice and the lower part of fridge was not cooling at all.
just took the back cover of the freezer of and then the fan. To do this, I just removed like four bolts at the corners and then four bolts that attached the fan to the cover. At the end, I just unplugged the cables. I got my new fan the very next day, which was like extremly fast, plug in the cables and attached the fan to the cover and then attached the cover to the original place. It's a pretty simple repair. My fridge is now working like it should be.
Parts Used:
Evaporator Fan Motor Kit
  • alonso from Compton, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Wrench (Adjustable)
9 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Erratic light.
Simple switch repair: Unplug fridge, pull down to remove switch assembly, slip contacts off. Reverse with replacement switch. HOWEVER, check first to see if the bulb filament might be broken, as this could cause the same symptom. OR in my case, the light socket connection was the culprit. Check that too before ordering a replacement switch.
Parts Used:
Door/Light Switch
  • D KIRKE from CORVALLIS, OR
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
9 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer and refrigerator stopped cooling
The site offers a video for this part which worked perfectly. In addition to replacing the part, since the cardboard panel was off, we also cleaned all the dust off of the coils which someone recommended to do annually.
Parts Used:
Run Capacitor
  • Amy from PITTSBURGH, PA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
8 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker failed
Watched YouTube video. Very easy. Used my cell phone camera in ‘selfie’ mode propped up in the upper right hand corner of freezer to see the 2 hidden screws.
Parts Used:
Refrigerator Ice Maker Assembly
  • Mary from SOUTH LYON, MI
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers
9 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
broken end caps
The end caps worked perfectly for both the Frigidaire and Westinghouse fridges. Just pulled out the old end caps and then literally just pushed in the new ones (remember to attach the shelf bar before attaching the second end cap!). The pieces arrived quicker than expected. Thanks Partselect!
Parts Used:
Door Shelf End Cap - Left or Right Side Door Shelf End Cap - Left or Right Side
  • Nana from Blaine, WA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
9 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
fridge side getting warm
Replaced both the thermostat and defrost timer and still froze up and still warm air to the fridge, turned out to be the defrost heater coil. It was cracked in the middle, very easy to test with a multimeter. Replaced the heater coil and all is like new!
Parts Used:
Defrost Thermostat Defrost Timer - 60Hz 120V
  • Benjamin from Mount Vernon, OH
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers
8 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
ice maker quit making ice
I basically followed the instructions offered when i searched for the ice maker. It was relatively easy to do, I undid the 2 screws holding the ice maker to the side of the freezer, the was the tricky part, holding a mirror so i could see the slots of the screws. loosened them, disconnected the electrical connection and reversed the process for the install. It took about 25 minutes and i was back making ice.
Parts Used:
Replacement Ice Maker
  • Barry from Middletown, DE
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
8 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the 25338652993