ice would not spill into bucket
The repair was very easy. I loosened the two screws holding the icemaker onto the side of the freezer, then unplugged the icemaker. Reversed the order, and it was done. You have to shut the water off first.
Parts Used:
-
Fredia from Benton, KY
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers
9 of 15 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Starter went out.
Unscrewed the lower back cardboard panel and removed it. Unplugged refrigerator. Reached in and took the metal piece off that keeps the starter from coming off. Pulled the starter off the compressor. Unplugged the starter from the power line. Replaced starter. Hooked power line back on. Hooked starter to the compressor. Put the metal piece back on to hold in place. Plugged refrigerator back in. Put back panel back on.
Parts Used:
-
Stuart from AMES, IA
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Socket set
6 of 6 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
my old ice maker leaked at the bottom
it was really easy changing the ice maker. the only trouble i had was the wiring. it was very stiff and hard to route. it did not work at first but that was my fault did not have the connector plugged in all the way.since then it works great.
Parts Used:
-
harry from terre haute, IN
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Nutdriver
7 of 9 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer compartment warm / Ice cream soft
I worked for GM as a Frigidaire Tech, before starting my own business. I have retired now.
I took the three screws off the back of the bracket holding the motor. Disconected wire harness and pulled out the motor. Reverse to install. servantoftheking@hughes.net
I took the three screws off the back of the bracket holding the motor. Disconected wire harness and pulled out the motor. Reverse to install. servantoftheking@hughes.net
Parts Used:
-
George from McBee, SC
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver, Socket set
9 of 15 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator Light bulb went out
I replaced the bulb using my hands to twist the bulb in the socket located at the top of the refrigerator.
Parts Used:
-
ANGELA from MEBANE, NC
-
Difficulty Level:Very Easy
-
Total Repair Time:Less than 15 mins
7 of 10 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Evaporator fan motor quit and would not circulate cold air from coils.
Remove shelves and rear panels to get to motor. Motor is held in place on shroud by simple strap. Remove fan blade, then un hook strap, remove and save rubber spacers on old motor to reuse to remount new motor. New motor Mew motor has wiring harness that is universal. Cut out the three wires that go to the new motor leaving long as possible, cut wires from old motor as long as possible, strip ends of all wires 1/2 inch, connect wires by color,slip into provided wire connectors and crimp. Pull on wires to insure connection. Tie wires together so they don't touch the coils. Plug in and check operation. If all is working unplug and replace all covers and shelves. Plug back in and it will take few hours to reach operating temperature. Video of side by side repair shows easy removal of panels and motor.
Parts Used:
-
Denver from BLAIRSVILLE, GA
-
Difficulty Level:Really Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver
6 of 7 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker stopped working (Very oxidized residue)
I removed the old ice maker and unplugged the cable. Screwed in the new one with a 1/4 nut driver at the 2 mounting screws, plugged cable in. Checked ice maker with a small level before final. All Ok and after night I had Ice and it has been working great since.
Parts Used:
-
Robert from Woodstock, IL
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Nutdriver
8 of 14 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fridge made a hellacious noise and wasn't cooling well
From discussions with friends, I determined the problem might be easy to fix. The fridge made a lot of noise, but the compressor DID come on, and inside the freezer was cold, but the main fridge was warming.
After unplugging the fridge, I removed the fan assembly in the freezer (there were about 4 nuts and a couple of plugs to uncouple.
I could see right away the fan blades has broken off, but the motor looked good. The new new fan pushed easily onto the shift and fit perfectly in the housing.
I reinstalled the fan assembly, plugged in the fridge, and right away heard the new fan come on - very quietly. What was a roar became a whisper and the fridge was down to 38 degrees with a few hours.
After unplugging the fridge, I removed the fan assembly in the freezer (there were about 4 nuts and a couple of plugs to uncouple.
I could see right away the fan blades has broken off, but the motor looked good. The new new fan pushed easily onto the shift and fit perfectly in the housing.
I reinstalled the fan assembly, plugged in the fridge, and right away heard the new fan come on - very quietly. What was a roar became a whisper and the fridge was down to 38 degrees with a few hours.
Parts Used:
-
Bruce from MARTINEZ, CA
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Nutdriver
5 of 5 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Replace ice maker which was splashing water
Turn off ice maker
Slide wire harness shield off connector
Disconnected harness
Loosened 2 wall screws
Remove old ice maker
Installed new one reversing process
Slide wire harness shield off connector
Disconnected harness
Loosened 2 wall screws
Remove old ice maker
Installed new one reversing process
Parts Used:
-
John from PHOENIX, AZ
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers, Wrench set
5 of 5 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
freezer frosting over,fridge warm
removed ice maker,,and screws holding back of freezer cover,unplugged wires and removed the cover and fan.wow,only wire to element had come unplugged!went ahead and replaced thermostat,and defrost timer,both were easy to do
Parts Used:
-
Brian from Otterville, MO
-
Difficulty Level:Really Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Screw drivers
8 of 14 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
I replaced the icemaker
I removed the two screws and unplugged it. I then attached the pigtail to the appliance, then to the fridge. I had to push the excess wire harness into the hole in the back. It took a few minutes to move the rest of the harness out of the way by curving it upward and securing it with a nylon tie.I ordered the ice maker from Part Select on Sunday night and it arrived at 8:32 Tuesday morning, THANK YOU! I ordered very simple weed cutter parts from Sears a week ago and they haven't even shipped yet!
Parts Used:
-
Michele from Smithfield, UT
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver
5 of 5 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
unit quit cooling
First I removed the two screws that hold the element in place. I then pulled the element out about 3 inches and disconnected the wiring harness plug, replaced the old timer with the new one, re-connected the wiring harness and reinstalled the mount in position. Hardest thing about it was lying on the floor.
Parts Used:
-
Steve from Cedar Park, TX
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Screw drivers
5 of 6 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
fan motor quit working
A little difficult getting out due to restricted space, I took off the fan blade, that gave extra working room. Then it went well going back together,and it all worked as advertised. Thanks. p
Parts Used:
-
Phillip from SUNDANCE, WY
-
Difficulty Level:Really Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver, Pliers, Screw drivers, Socket set, Wrench (Adjustable)
4 of 4 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer was not defrosting
Turned off fridge circuit breaker
Removed all food from freezer and put in cooler.
Removed shelves from freezer
Removed ice maker
Removed 2 hex head screws
Tilted back evaporator cover and tried to unplug connection.
Found connection was iced over with a huge block of ice coming from water inlet to ice maker
Spent several hours trying to melt and chip away ice without damaging fridge.
Finally was able to break up ice with long flat head screwdriver and hammer.
Unplugged connector and was able to remove evaporator cover.
Cut wires near thermostat and removed
Stripped wire as needed and crimped new thermostat in place.
Used heat gun and lighter to melt heat shrink. This took a long time and required a lot more heat than expected.
Reconnected evaporator cover connection and reattached cover.
Reinstalled ice maker
Reinstalled shelves.
Put food back in
Turned circuit breaker back on.
Removed all food from freezer and put in cooler.
Removed shelves from freezer
Removed ice maker
Removed 2 hex head screws
Tilted back evaporator cover and tried to unplug connection.
Found connection was iced over with a huge block of ice coming from water inlet to ice maker
Spent several hours trying to melt and chip away ice without damaging fridge.
Finally was able to break up ice with long flat head screwdriver and hammer.
Unplugged connector and was able to remove evaporator cover.
Cut wires near thermostat and removed
Stripped wire as needed and crimped new thermostat in place.
Used heat gun and lighter to melt heat shrink. This took a long time and required a lot more heat than expected.
Reconnected evaporator cover connection and reattached cover.
Reinstalled ice maker
Reinstalled shelves.
Put food back in
Turned circuit breaker back on.
Parts Used:
-
David from N KINGSTOWN, RI
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:More than 2 hours
-
Tools:Nutdriver, Pliers, Screw drivers
4 of 4 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
I had a broken fan blade due to ice build up from a leaking ice maker.
1. I took out one screw on the ice maker and loosened the other two screws and unplugged and removed the ice maker.
2. Next I took out 2 screws from the bottom of the auger drive box and unplugged the wiring harness and removed the box. The wiring harness was a little tricky. The lock on the plug pushes in to unlock even though it looks like it pulls out,.
3.next you must remove 2 screws from the left side bracket that holds the auger box and remove the bracket.
4.Now take out 8 screws that hold the back panel in place and remove the back panel.
5. now your looking at the evaporator fan blade and motor. The simple way to replace the fan blade is to unplug the motor and remove it from the freezer. It just sits in with nothing holding it. The fan requires a little pressure but should pull right off. Install new fan blade and put everything back in the same order it was removed.
2. Next I took out 2 screws from the bottom of the auger drive box and unplugged the wiring harness and removed the box. The wiring harness was a little tricky. The lock on the plug pushes in to unlock even though it looks like it pulls out,.
3.next you must remove 2 screws from the left side bracket that holds the auger box and remove the bracket.
4.Now take out 8 screws that hold the back panel in place and remove the back panel.
5. now your looking at the evaporator fan blade and motor. The simple way to replace the fan blade is to unplug the motor and remove it from the freezer. It just sits in with nothing holding it. The fan requires a little pressure but should pull right off. Install new fan blade and put everything back in the same order it was removed.
Parts Used:
-
gary from ARANSAS PASS, TX
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver
5 of 7 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!