unit quit cooling
First I removed the two screws that hold the element in place. I then pulled the element out about 3 inches and disconnected the wiring harness plug, replaced the old timer with the new one, re-connected the wiring harness and reinstalled the mount in position. Hardest thing about it was lying on the floor.
Parts Used:
Defrost Timer - 60Hz 120V
  • Steve from Cedar Park, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
One blade broke from condenser fan
The part i recieved, from parts select was a larger in circumfrence (<1/4) than the original. However i was not aware of this until after i treid to repair it.

I removed the broken fan from the condenser. This was very sipmle.

When i pluged the refridgerator back in to the outlet the fan tried to start up but soon began to make aloud noise, due to there not being enough clerance.
Parts Used:
BLADE-CONDENSER FAN
  • Chris from Lockport, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
10 of 22 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Warter valvr cracked
It was real easy but I still have problem making ice cubs
Fell problem is in the ice maker went it dose make cubs they don,t dump
Parts Used:
Water Inlet Valve
  • Louis from Damascus, PA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
7 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Coming from the refrigerator, there was an intermittent "clicking noise", occurring about every 30 seconds. The frig. eventually failed .
I removed the back cover and removed the clip holding the compressor- run capacitor and start relay. I replaced these 2 components and clean the dust from the frig., and from the bottom of the floor. I replaced the back cover ; Loss about $300 worth of meat when when the frig. failed. Then I thought that, during these turbulent times, there are many which don't have a refrigerator or any meat to place in it, The refrigerator is "running" normal again.
Parts Used:
Run Capacitor - 120V
  • winifred from LOUISVILLE, KY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Replace ice maker which was splashing water
Turn off ice maker
Slide wire harness shield off connector
Disconnected harness
Loosened 2 wall screws
Remove old ice maker
Installed new one reversing process
Parts Used:
Refrigerator Ice Maker Assembly
  • John from PHOENIX, AZ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Wrench set
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator Light bulb went out
I replaced the bulb using my hands to twist the bulb in the socket located at the top of the refrigerator.
Parts Used:
Light Bulb
  • ANGELA from MEBANE, NC
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice Maker ffss2614qpo
Looked it up on how to, follow the video
. Very easy 1-2-3 it was out and new one in..........??.
Parts Used:
Refrigerator Ice Maker Assembly
  • Dante from SOUTHOLD, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
freezer defrost would melt the food
Looked up similar problems and found it to be the defrost timer. All I had to do was remove the plastic portion in the fridge section to get to the old timer. Popped the new one in and put it back together. Works great now. Would have been almost $150 to have a repair company come out and fix it.
Parts Used:
Defrost Timer - 60Hz 120V
  • Joseph from West Allis, WI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
ice maker went bad
take the ice bin out of freezer. there are 2- 1/4" screws. these screws only need to be loosened a few turns. the ice maker can be slightly lifted up and will come off the screws. unhook the wire harness. take the "L" bracket off the old ice maker and put on the new one. set the new ice maker in. hook up the wire harness. put the new ice maker over the screws, tuck the wires out of the way and pull down into place. tighten the screws.
Parts Used:
Replacement Ice Maker
  • nathan from gillette, WY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer icing up and refrigerator section not cold
Removed four screws for cover on refrigerator temperature controls, unpluged old timer and pluged in new timer. Replaced cover and screws.
Parts Used:
Defrost Timer - 60Hz 120V
  • Les from Fenton, MO
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Old Defrost Timer Noisy During Operation
First I removed the plastic grill (pulled out, no screws) from bottom of refrigerator, then I removed electrical plug & two screws from old timer (timer located on the front inside left lower side of refrigerator). Installed in reverse order.
Parts Used:
Defrost Timer - 60Hz 120V
  • Vernon from Granada Hills, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Socket set
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker quit working
Remove ice pan below ice maker. Got mirrow verifed the type of screws. Obtained nut driver and felt it at right angle remove screws only have way. The ice maker lifts up and off. Took needle nose pliers to grip and remove electrical connection plug. The instruction and picture sent was no help the picture were the size of a thumb nail no detail could be determine. I installed the adapter plug and all the extra length wiring was the most difficult to type wrap with both hands extended out in front. I finally wrestled it in on to the two screws unscrewed from the wall about 1/2". Keep the ice maker water lever up and ensure it aligns to the water trough inlet. Works Great.
glg
Parts Used:
Replacement Ice Maker
  • Gary from Granbury, TX
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Drive great stripped for ice eject. Heater bad
Loosened the 2 bolts 4 turns where it mounts inside the freezer. Lift maker off the bolts unplug 1 plug. Reverse to install.
Parts Used:
Refrigerator Ice Maker Assembly
  • Danny from PUEBLO, CO
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Not running
After waiting over 2wks for my part to arrive, I purchased the part locally and made the repair the same day as I am still waiting for the part to arrive from you guys. Your customer service really needs improving. I paid for 2 day shipping, what a joke. I will be returning the part as soon as I receive it thanks.
Parts Used:
Cold Control Thermostat
  • Kenneth from SAVANNAH, GA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
defrost heater not working; defrost timer not rotating so coils ice up
Checked for continuity in heater, defrost thermostat and defrost timer. Heater good; not sure about thermostat or timer. Replaced thermostat - no change. Replaced timer - rotating and heater working.
Parts Used:
Defrost Timer - 60Hz 120V
  • James from VOLANT, PA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the 25331444303
61 - 75 of 307