Models > 25331442301 > Instructions

25331442301 Kenmore Refrigerator - Instructions

All Instructions for the 25331442301
16 - 30 of 370
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Ice Maker stopped working
Reviewed the video on your website and followed the directions to the letter. Great video
Parts Used:
Refrigerator Ice Maker Assembly
  • Dennis from DEER LODGE, MT
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
38 of 45 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Did not make ice
First I removed the two screws that hold the element in place. I then pulled the element out about 3 inches and disconnected the two wires. Then I took the new icemaker out of the box and reversed the procedure.

The icemaker is making ice now.
Parts Used:
Icemaker Assembly
  • Brenda from Sanford, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
36 of 51 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Brand new refrigerator, but evaporator fan blade broken, causing considerable vibration and noise.
Really, really, really easy:
1.Unplug refrigerator (electrical safety).
2.Remove cardboard cover at bottom of refrigerator (two short self-tapping bolts) with a wrench.
3.Pull old fan blade off fan motor shaft (just held on by a compression fitting--no tools needed).
4.Push new fan blade on shaft.
5. Replace cardboard cover.
6. Plug in refrigerator, write nasty letter to Frigidaire.
Parts Used:
Fan Blade
  • John from Morgantown, WV
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Wrench (Adjustable)
30 of 34 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator wouldn't defrost
First, I replaced the defrost timer, really easy, 4 screws popped the cover of the electronic area (top of refrigerator compartment) took it out and plugged in the new time. Unit still would not defrost, so replaced the thermostat as well. Bit harder, removed ice maker, 2 screws, back plate from freezer, 4 screws. Thermostat was clamped to a copper tube- the original had one of the wires hanging out of it- cut the wires and crimped the new wires on, shrunk the plastic tube with blow dryer over the wires (taped them for good measure) and so far so good. Learned most of this through these tips, so keep reading if this isn't your problem, just save myself $1000 on a new refrifgerator...
Parts Used:
Defrost Thermostat Defrost Timer - 60Hz 120V
  • Patrick from Gansevoort, NY
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers
30 of 35 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The old ice maker had stopped working properly. The cycle was inconsistent, and inlet water would run over existing cubes in the tray, before they were dumped into the dispenser box.
This was really simple, much like changing a light bulb. Two bolts loosened beneath the old unit to allow it to be lifted off and free. The power supply plug was easily disconnected. The new unit was then placed onto the loosened bolts, power supply reconnected and secured with the supplied wire tie. A small angled bracket was removed from the old and reattached to the new as a support toward the from of the unit. The cycle adjuster was backed off a 1/2 turn as per the instructions....and the next morning....new automatic ice. Life is good!
Parts Used:
Replacement Ice Maker
  • Daniel from Baldwin City, KS
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
28 of 30 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
no cooling in fridge or freezer due to bad defrost timer
i removed the 4 screws holding cover. removed two screws holding timer. unplugged timer. plugged in new one. reassembled.
Parts Used:
Defrost Timer - 60Hz 120V
  • Todd from pottstown, PA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
29 of 36 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Old icemaker would not cycle to make ice.
I had already removed the ice maker by loosening the two screws with a 1/4" nut driver, in order to compare the design and style to the intended replacement for size and critical measurements. The replacement was almost identical. The wiring harness was 2-3" longer than the original, but after snaping the wire plugs together I simply curved the wire up and to the left to be out of the way. The hanging brackets are slotted and it was easiest to slip the back hanger over the head of the screw and let it slip down, then the front hanger was already to line up even though you can't see the screw with the ice maker in the way. I had to transfer an L-shaped metal bracket to the bottom side, matching the old assembly, and adjusting it to hold the bottom side away from the freezer compartment a little so it would hang level and secure. You have to snug the two screws with a screw driver or 1/4" nut driver by feel, since you can't see them with the icemaker in place. It took about 10 minutes to take out the old and another 10 to put in the new. We now have a full bin of ice, and the old plastic trays have been retired. I should have done this a year ago.
Parts Used:
Replacement Ice Maker
  • David from Cedar City, UT
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
24 of 26 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker quit working
Loosen two screws, unclip electrical connection, remove ice maker, remove l shaped leveling piece of metal from old one, put on new one. Install in reverse order. Hint.. when loosening two screws, use a mirror
Parts Used:
Refrigerator Ice Maker Assembly
  • Robert from SIOUX FALLS, SD
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
27 of 35 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The evaporator coil in the freezer would cake up with ice, choking off the cold air flow into the lower refridgerator compartment. A repair man had previously replaced the defrost heater element, but this did not fix the problem.
First, unplug the refrigerator since you're working with live wires.

Remove the 4 Philips sheet metal screws holding the plastic housing that holds the temperature control to the top of the refrigerator compartment. Pull the housing down then out since there is a tube on the housing where the water flows out the back of the refrigerator during the defrost cycle.

Remove the 2 Philips screws holding the defrost timer on the plastic housing. Pull the connectors off the old timer and attach them in exactly the same positions on the new defrost timer.

Attach the new defrost timer to the plastic housing with the 2 screws.

Reinstall the plastic housing, making sure the water tube is inserted into the back of the refrigerator wall.

Plug the refrigerator back in and you're done.
Parts Used:
Defrost Timer - 60Hz 120V
  • Erle from Boise, ID
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
24 of 27 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
freezer and fridge stopped cooling. Could hear compressor clicking on, smelled electronics overheating, starter melted.
remove the rear cover, and simply pull off harness and replace starter.
Parts Used:
Refrigerator Compressor Start Relay Kit
  • ron from hawthorne, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
30 of 46 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water Was Not Being Sent Up To Ice Maker
I removed a couple of screws from the old part, and inserted the new part. Replaced the screws and I was done. No problem. I'm an almost 60 year old woman, and fixed this myself. It was so easy.
Parts Used:
Water Inlet Valve
  • BARBARA from DIAMOND, IL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
27 of 37 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
top freezer working properly, but lower fridge not cooling.
since I had my fridge since 2003 it seems that I've gotten my moneys worth but it has worked flawlessly with no issues. I did not want to part with it so I troubled shoot the system and realized that it could have been number of things so I just decided after reading some reviews here on this site I decided to just purchase the items that would be effecting the fridge not working properly which was the evaporator fan, defrost thermostat, defrost timer, temperature cold control thermostat, I also cleaned the condenser coils in the back of the unit so they can be able to withdraw heat from the unit. my repair and installation took about 4 hours due to the cleaning of the coils but now the fridge is working like brand new. thanks to this sitt and it's comprehensive video tutorials on installations and repair it my job a lot easier to do.this is not my first time ordering from this site and will not be my last. anyone considering ordering from this site do not hesitate there are great with parts and customer service.
Parts Used:
Evaporator Fan Motor Kit - 120V 60Hz Cover-fan Cold Control Thermostat Defrost Thermostat Defrost Timer - 60Hz 120V
  • Charles from NEW YORK, NY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Nutdriver, Socket set
23 of 27 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator light was out
Test the light socket first with a bulb that you know is good. If the light still does not come on, unplug the refrigerator, remove the switch by inserting a very small, thin, flathead screwdriver alongside it and pull the switch out slowly with your other hand. There are two wires there. Remove them gently with some needle nose pliers. If you want to test to see if the switch is defective, take a insulated jumper wire, and attach it between the two wires. Plug the refrigerator back in and see if the light comes on. If the light does come on, replace with a new switch by re-attaching the wires and placing it back in the hole firmly.
Parts Used:
Light Switch
  • andy from Peshastin, WA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
25 of 35 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer worked great, refrigerator would not cool
Removed (unsnapped) plastic cover from back of refrigerator ( inside freezer compartment), determined that the fan was not turning, removed 4 screws from the aluminum back plate in freezer and tilted it down. Removed 2 screws with a nut driver, this allowed the fan to be removed, unpluged fan motor from the bace of the freezer and removed fan. Installed new motor and spent $38.00 to repair the refrigerator that would have cost me severial hundred dollars to replace. Thanks for the help
Parts Used:
Evaporator Fan Motor Kit - 120V 60Hz
  • Farrell from Atchison, KS
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers, Wrench set
21 of 25 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The bottom of Refrigerator would not get below 48 degress. Freeezer was working fine.
First I unplugged fridge. I then removed cover that keeps fan protected. I then removed 2 screws that hold the evaporator motor in place. I then removed 3 wires running to motor. Very easy to remove, just pulled connections apart. I then replace the old motor with new.

The Sears repairman wanted to charge me $359 to repair. I did repair for under $40! Amazing what you can save if you have the time and knowlege to do it yourself.
Parts Used:
Evaporator Fan Motor Kit - 120V 60Hz
  • Jeffrey from Bridgeville, PA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Socket set
25 of 38 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the 25331442301