refregirator too warm
I order defrost timer then replaced it but it seemed doesn't work. I order defrost thermostat again then it worked fine until now. Thanks. Part selects.
Parts Used:
Defrost Timer - 60Hz 120V
  • HUNG from KENT, WA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
Was this instruction helpful to you?
Thank you for voting!
Refrigerator warm and freezer defrosting too quickly.
1. Disconnected electrical. 2. Removed upper console in refrigerator by removing 2 nuts. 3. Disconnected wiring from console. 4. Removed 2 screws from defroster timer part and pulled off from connector. 5. Replaced with new defroster timer and put everything back together. Thank you Steve for the U-Tube step by step video.
Parts Used:
Defrost Timer - 60Hz 120V
  • Bertha from Lakewood, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Socket set
Was this instruction helpful to you?
Thank you for voting!
Limited cooling in freezer and refrigerator, ice build up.
Followed Internet video instructions for both parts. Two suggestions: Forget the heat shrink tubing and use electrical tape instead, tubing is short in length and difficult to use unless you have a correct heat gun. Secondly, my timer didn't click twice but due to instructions I could determine that the timing was correct in the operation after the first click. This method could be explained as well as when to start it in connection with usage to be the most efficient in temperature and operation.
Parts Used:
Defrost Thermostat Defrost Timer - 60Hz 120V
  • Wayne from East Alton, IL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
The refrigerator part was not cooling enough
I watched the video online where it described the troubleshooting tips for this type of symptom. So I knew exactly what the problem was which is the defrost timer. After the part came in I just unscrewed (4 screws) the box which houses the thermostat and the defrost timer from top ceiling of the refrigerator section. Then I just unscrewed and unhooked the old defrost timer and replaced it with the new one. After finishing the installation I turned the fridge on. At first nothing happened. So I turned the dial on the defrost timer with a flathead screw until it clicked and the fridge came alive. I waited for an hour or so. The cooling cycle completed and the fridge stopped as expected. When I opened the door I noticed the interior is much colder than before and right after closing the door the fridge hummed back into life again. So I know my fridge is working again. Thanks to PartSelect for providing the right part for my refrigerator. I will definitely buy from them again if anything goes wrong.
Parts Used:
Defrost Timer - 60Hz 120V
  • Mainul from Portland, OR
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Weird Noise that continued for at least 60 seconds control OFF.
Unplug the refrigerator. Removed the right hand top shelf. Used a 1/4" nutdriver to remove rear center mounting screw for Control Housing. Used Phillips screwdriver to remove two mounting screws for timer. Unplug cable from timer and plug it into the new timer. Install the new timer and re-install the Control Housing. Plug in the refrigerator and adjust the timer to start the unit. This was a snap with the diagnostic provided by Part Select. At first I thought it was the fan rubbing but when I removed the cover (two screws) it was obvious that wasn't the problem. The diagnostic hinted that it was either the timer or the motor capacitor making the noise. Because the noise continued after turning OFF the control, I thought it was the timer...I was right.
Parts Used:
Defrost Timer - 60Hz 120V
  • Donald from Round Rock, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
both ref&frez were hot
1 went with maj 69% said defrost timer. NO. 2 went with second choice run cap NO. 3 went with my thought, ( PTC Starter ) why not, most exp part. Fixed the problem.
Parts Used:
Defrost Timer - 60Hz 120V
  • Gary from Dunnellon, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Unit keep cutting off
Ordered the new part-Unplugged the refrigerator - took off the cover over the defective timer - put in the new part put the cover back on - plugged the refrigerator back in - so far, so good!~
Parts Used:
Defrost Timer - 60Hz 120V
  • Ed from Memphis, TN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
has lights,no fan or compressor
jump thermostat,fan and compressor came on, ordered thermo from this excllent parts supplier, part came in 4 days later, it was exact replacement, works exactly right!
Parts Used:
Cold Control Thermostat
  • francis from arlington, WA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
Was this instruction helpful to you?
Thank you for voting!
Refrigerator section not cooling
Checked defrost timer. It was a shocker: it was completely burnt out. Replaced it with the new part very easily. I thought now it would defrost properly but unfortunately the thermostat also was shot. I had ordered it along with the timer just in case. It was not expensive at all and I saved time but having it with me when I replaced the timer. NOW ALL IS WELL AND REFRIGERATOR SECTION COLLING PROPERLY. THANKS TO VIDEO AND PARTSELECT.
Parts Used:
Defrost Thermostat Defrost Timer - 60Hz 120V
  • Anant from Stone Mountain, GA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Not getting cold in lower Refrigerator
Watch the video provided by PartSelect and did exactly the same percedure. Shows what screws to remove and how to remove and replace the part. The freezer compartment was iced up quite a bit so defrosted it before installing part.
Parts Used:
Evaporator Fan Motor Kit - 120V 60Hz
  • Charles from Wallingford, CT
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Refrigerator warm, but freezer slightly cold
The website said 60% of people with same refrigerator problem solved the problem with a new fan kit. I received the fan kit within 3 days of ordering. Was shipped from Fresno, CA to Long Beach, WA. The fan kit was to be installed behind rear panel in the freezer compartment. When I removed the old fan motor, I noticed the shaft turned harder than the new fan motor, suggesting a problem with the old fan motor. I plugged in the obvious fan motor power bundle with no problem. The instructions and diagram with the kit nearly steered me wrong. Instructions, diagram and splices with the kit instructed to cut the "extra" wire bundle and splice "similar" wires (should have said same color wires). Luckily, I ignored those instructions when I remembered the U-Tube video depicted the extra wire bundle was to be inserted into a factory penetration in the back panel, facing the freezer compartment. This power bundle is for adding an ice maker, which my refrigerator did not have. When reassembled and the refrigerator restarted, I could immediately feel forced air in the refrig, where there was no flow before fixing. I observed that all the refrig and freezer dials do is act like a valve to increase or decrease air flow to the compartments. The dials have no mechanical or electrical connections, just designed to divert air flow from across the cold 'evaporator' fins. I recommend other consumers to remember carefully what they see in the video and watch again if stumped during the job. The video was better than the instructions which may have been written in China or India. I am happy. Repair was a lot cheaper than a new refrigerator and I would not have bought another Frigidaire. Thanks to this website. r. andersen
Parts Used:
Evaporator Fan Motor Kit - 120V 60Hz
  • RONALD from LONG BEACH, WA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Heater not coming on - coil frosting up- freezer and Refrig. warm
The instructions given to me by part Select were very good.I replaced the Timer- checked the heater with oham meter it was good- checked the door weather striping it was good and replaced the thermostat with new .So at this point I may need to call a professional unless some one has another solution.
Parts Used:
Defrost Timer - 60Hz 120V
  • James from merrillville, IN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Frig Section Too Warm,Freezer Ok
Using your online troubleshooter, it was probably the defrost timer and/or the defrost thermostat. Both cheap so I ordered both. The online repair videos showed how to replace those parts. Replaced the timer first with no problems. Removed the panel at the freezer back an saw a streak of black smoke on the white panel wall above the thermostat. Good chance this was the failure point. Video also showed how to replace this unit without any problem. Set the temperature control and let the frig run over night. Problem solved!frig at 38d and freezer at 0d.
Parts Used:
Defrost Thermostat Defrost Timer - 60Hz 120V
  • LANCE from AURORA, CO
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Fridge not cold enough
The freezer was still making ice, but the fridge portion was barely cooler than room temp. I came to the website and saw that the defrost thermostat cured this problem over half the time. I was quite dubious because I don't see how that would affect the non-freezer part of the compartment, but since it was a cheap and easy-looking repair, I figured what the heck, lets see if that's it. Sure enough, it's like new again. I still don't understand it, but I'll take it. The repair itself is simple, just cutting out the old switch and splicing in the new. Two wires, and clip it to the copper tubing where the old one was. The switch is accessed easily after taking out four screws in the back of the freezer compartment. The only hard part was removing the ice-maker, and that's just because the two screws that hold it in are a little hard to get a good grip on. Alas, you have to get the ice-maker out to pull out the back panel, so there's nothing for it but to wheedle those screws out.
Parts Used:
Defrost Thermostat
  • Ross from Murphy, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers, Screw drivers, Socket set
Was this instruction helpful to you?
Thank you for voting!
freezer was icing upp and not defrosting
just followed the instructions from part select website - everyone is a repair man with the easy to follow and attention to detail the videos provided - time will tell I replaced the defrost timer and thermostat at the same time - the refrigerated was running a lot and the freezer was icing up on the back right of the freezer compartment mostly - " it has been doing this since the day we bought it from sears - we had a repair man over more than once but still had the same problem and had to max out the controls to keep things close to were they were suppose to be temperature wise. we also purchased a few extended warranties The freezer was running around 15 degrees and running all the time. The heating element checked out at 35 ohms so it must be ok. Will let you know in a few days. One serviceman even tried to say it was frosting up because we didn't have ac lol
Parts Used:
Defrost Thermostat Defrost Timer - 60Hz 120V
  • Ron from Gladstone, MI
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
Was this instruction helpful to you?