25328452801 Kenmore Freezer - Instructions
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Replaced drawer slides L & R
Removed three screws each side to remove old slides. Needed spacers under new slide so that drawer would stay on track. Cut old slide to make spacers and installed both slides in 15 mins.
Parts Used:
-
Richard from GAINESVILLE, GA
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Freezer would not keep running and the temperature was too warm.
Followed the sites instructions. Empty the bottom part of the freezer. Remove the screws. Move the panel out of the way. Easily remove the old part and replace with the new. Put the panel and screws back in place. The freezer works.
Parts Used:
-
Edmond from Carroll, NH
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Evaporator Fan Motor was making loud rattling sound.
Unplugged freezer from electrical socket. Removed lower trays from freezer. Removed sound proof stripping from sides of back panel. Removed upper, lower and side screws from back, lower panel using No. 2 phillips screwdriver. Disconnected motor wires from quick disconnect power supply. Removed motor bracket from freezer back using nut driver. Removed motor from bracket using same nut driver. Replaced motor and screws in bracket. reattached quick disconnect. Attached fan blade to motor making certain to push blade on shaft securely. Replaced bracket to freezer back. Replaced back cover. Replaced stripping. Plugged into power supply. Total time 15-20 minutes.
Parts Used:
-
Richard from Clovis, NM
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Noisy fan
Remove the cover panel inside the freezer, remove and replace the fan motor (pull fan blades off old motor and push on the new one) and replace the cover.
Parts Used:
-
CRAIG from PRESCOTT VALLEY, AZ
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Freezer only cold on bottom
Pulled freezer out from where located to allow shelves to be removed.Unplugged unit, removed shelves and evaporator cover, installed new fan motor. Plugged unit up to check fan motor operation. Reassembled unit, installed shelves and moved freezer back into original location.
Parts Used:
-
Richard from Warren, TX
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers
Was this instruction helpful to you?
Thank you for voting!
compressor not running
thanks to all of the people who had the same problems I was able to make a quick fix on my fridge. I pulled the back cover off and found the compressor not kicking on so I replaced the start cap. and im back in bussiness.
Parts Used:
-
wilson from indialantic, FL
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Nutdriver, Wrench (Adjustable)
Was this instruction helpful to you?
Thank you for voting!
stop-basket was broken
-
Kenneth from Tahlequah, OK
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
Was this instruction helpful to you?
Thank you for voting!
Fan would not start occasionally
I unscrewed the screws that held the old fan on, disconnected the wiring harness and removed the old fan. I pulled the blades off the motor and put it on the new fan. One thing of note, the screw holes on the new fan weren't threaded. I assume this is by design, so I used the screws to thread the holes before installing it in the freezer. Once I did this, the rest of the installation was easy, just screw it back in and connect the wiring harness.
Parts Used:
-
Mike from Satellite Beach, FL
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers
Was this instruction helpful to you?
Thank you for voting!
freezer not cooling
inspected visible refrigeration lines for evidence of leaking, found nothing substantial that would cause concern, ordered capacitor and defrost thermostat simply because both are inexpensive parts and theoretically either could be causing the problem. Both parts were very simple to install especially since I am a semi-retired refrigeration man.
Parts Used:
-
Shawnda from Union City, PA
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
freezer door got locked and we couldn't find the key
-
Linda from Fresno, CA
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
Was this instruction helpful to you?
Thank you for voting!
door switch broke
Removed bottom cover , just two screws , slid old part through install hole and removed wires from old switch and installed on new switch. Installed new switch in same hole and pushed gently until it locked in place. Reinstalled bottom cover and done.
Parts Used:
-
Ricardo from VICTORVILLE, CA
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Screw drivers
Was this instruction helpful to you?
Thank you for voting!
the compressor capacitor overheated
it was great. I ordered the capacitor for my frigidaire frig and it arrived
in 3 days. plugged in the part to the compressor and my frig has been
working ever since. I spent 3 minutes ordering the part and 30 seconds
attaching it to the frig. Easy, very easy. saved myself a 75 dollar repair
visit. thanks
in 3 days. plugged in the part to the compressor and my frig has been
working ever since. I spent 3 minutes ordering the part and 30 seconds
attaching it to the frig. Easy, very easy. saved myself a 75 dollar repair
visit. thanks
Parts Used:
-
Bart from goldsboro, NC
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Would not freeze or defrost
Unplug freezer let stand all night to defrost. Remove the tray cover which is located on the upper back area inside the freezer.( 3 twist fittings remove it ). Remove the upper stainless steel panel which is secured with 6 screws. This will drop down exposing the condenser. Note all the wires and fan will stay attached to the stainless steel panel, this panel will drop down no need to unplug anything. On the left upper side next to the condenser you will see the thermostat. Two color coded wires. Remove the thermostat and install the new one at the same location.
Parts Used:
-
RONALD from Sevierville, TN
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
condenser fan stop working
Replaced fan. I ordered the fan and received it the following.(-:
Parts Used:
-
George from Gilroy, CA
-
Difficulty Level:Really Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver, Screw drivers, Socket set
Was this instruction helpful to you?
Thank you for voting!
refer quit cooling and so did freezer
I replaced the defrost timer,defrost thermostat,and run cap.as it turned out the compressor went bad. I dont know the model because but the time I got this review I replaced the refer with a knew one . two weeks living out of coolers was so much fun !!!!!!!!
Parts Used:
-
jerry from petaluma, CA
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
Was this instruction helpful to you?
Thank you for voting!