Burner on 'high' only, no other settings other than 'off'.
SHUT OFF BREAKER! Remove exhaust grill and switch knob. Remove cooktop switch panel by removing two screws and sliding panel toward exhaust grill. Remove switch retainer nut with deep socket. Transfer wires one by one to new switch. Install new switch tightening retainer nut. Reinstall switch panel with two screws, push knob onto shaft. Turn on breaker.
Parts Used:
Infinite Switch
  • Janes from Marquette, MI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers, Socket set
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
old filter to replace
:-) - Just removed the old one and replace with the new one. Nothing to it. Takes 30 seconds.
Parts Used:
Grease Filter
  • Colette from Baton Rouge, LA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Downdraft blower motor noise, fluctuating fan speed and binding. Also replaced indicator light for burner knob.
1. Turned off electrical breaker at electrical service panel.
2. Tested stove top to verify correct breaker was off as well as cook top.
3. Removed front electrical connection panel @ cook top.
4. Disconnected wires to blower fan. (Before disconnection I color coded wires for correct reconnection)
5. Removed the bracket holding the armored cable (protecting motor wires) and removed wires (where connects to electrical connection box).
6. Removed 4 nuts @ blower motor housing and removed blower motor housing and fan.
7. Removed 3 screws that attached the blower fan to the blower motor housing noting or marking the position of the housing to the motor bracket in order to have the same placement position.
8. Pulled the 3 connecting wires from the armored cable protector to separate housing from motor.
9. Removed the fan assembly from the blower motor shaft by using an allen wrench carefully noting the distance from motor face to the fan.
10. Noting/marking the position of the motor mounting bracket connections unscrew the nut and screw that secures the bracket to the motor.
11. Reassemble in reverse order.
Note:
I taped the motor wires tightly together every 3 or so inches to be able to slide through the armored cable.
I also had to rotate the mounting bracket a little to be able to perfectly match the motor housing to the motor bracket.

The new fan motor works great but it's a little bit louder.
Parts Used:
Motor Isolator Indicator Light Kit
  • John from FRESNO, CA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Screw drivers, Socket set, Wrench set
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Half of elements didn’t heat
Your staff helped me find the updated replacement that worked and when I was having some connection issues helped me get it right!
Parts Used:
Infinite Switch
  • Ray from NESCONSET, NY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Wrench (Adjustable)
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Origin knobs cracked
Just slip new knobs on. Simple and works great!!
Parts Used:
Surface Burner Knob Kit
  • Lora from SEBASTIAN, FL
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Burners were not regulating and they were just going on high
I am not really handy. When the repair man came and gave me a price of $220 to repair two infinite switches, I looked up the cost of the switch and saw that it was easy to do...and it was! I saved $140 for doing it myself (no help from my husband).

First I turned off the power, unscrewed two screws and took the knob panel off. Wrote down the colored wires and then pulled them off the infinite switch (some needed pliers) and then i just put the wires back on the new switch...done...it works!
Parts Used:
Infinite Switch
  • Debra from Syosset, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Hmm, let's see, knob didn't match all my other new knobs
Oh this was a toughie and I was sweating it out.
With a delicate touch I removed the old knob and pushed on the new knob, 5 seconds
Parts Used:
Grease Filter Surface Burner Knob Kit
  • James from Devon, PA
  • Difficulty Level:
    Very Difficult
  • Total Repair Time:
    Less than 15 mins
3 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Replace burnt out indicator light
I feel that the design of the indicator light, with the base attached to the bottom of the lens, is ingenious in that it eliminates the need for fasteners in that confined space, However, the plastic used for the base needs to be more flexible. Part of the base broke off in trying to force the base over the bottom of the lens. Fortunately, there was enough left on the base that I could slip it over the bottom of the lens and complete the installation.
Parts Used:
Indicator Light Kit
  • Melanie from SALIDA, CO
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Install New Vent Cover
Installation was straight forward as the new vent cap was sized correctly for exhaust pipe (5 inch). Placed the mounting plate into the exhaust pipe and used 4 SS screws to anchor to house sheathing. The vent flapper was not flat, requiring that I carefully stress relieve it at 250 degrees and hold it flat while cooling to take warp out. Snapped it in place afterwards and then bolted on cover.
Parts Used:
Wall Vent Cap Kit - 5 Inch duct - with Gray Cover
  • Brent from EAST LYME, CT
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Right front burner switch burnt out
Shut off power. Removed screws holding panel.Removed wires from old switch.Installed wires on new switch and reinstalled panel.EASY
Parts Used:
Infinite Switch
  • FRANCIS from MILLBURY, MA
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Burn was full on or "high" at any switch position other than off.
Followed other's instructions from the web site: First - turned off the power at circuit breaker; removed two screws from downdraft vent area; pushed the switch housing back towards vent and lifted; held replacement switch next to defective switch and removed and replaced one wire at a time; loosed switch collar-nut and swapped defective switch for new one. Only issue was the "rat's nest" of wires gave very little room to work, especially if you have average sized hands.
Parts Used:
Infinite Switch
  • Owen B Douglass from BROOMALL, PA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
parts needed to be replaced
Hubby & I
Parts Used:
Surface Burner Knob Kit
  • Phyllis from MAPLE VALLEY, WA
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    15 - 30 mins
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The original grease filter was damaged in our dishwasher (it is quite fragile) and needed to be replaced.
1. Remove the exhaust vent cover, located in the center of the top of the range. It just lifts off.
2. Swivel the clamp 90 degrees to release the filter.
3. Remove the filter and throw it away
4. Place new filter in place and lock in place by rotating the swivel clamp back 90 degress.
5. Replace the exhaust vent cover
Parts Used:
Grease Filter
  • Martyn from Middletown, OH
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
blower motor was making loud noise
removed motor, saw that stablizers were broke and went to a local parts supply shop called SUNDBERG and was given a price of about 49.00 for three stablizers. at that point i went to the internet and found PARTSELECT.COM were i found the same parts for a fraction of the price,17.00, i could not believe it! SUNDBERG customer service was horrible.PARTSELECT custormer service is great and was just over the internet,any how the repair is done no more loud noise and wife is happy again ,for awhile.thanks keep up the good work.i tell everybody about you guys.
Parts Used:
Motor Isolator
  • alphonso from plainfield, IL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers, Socket set, Wrench set
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
broken sens
removeed the dial cover, paced the lens into the hole, slid the light and holder into place , 5 min job.
Parts Used:
Pilot Light Lens - Red
  • Dennis from Mahomet, IL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!