Gas dryer would not heat - pilot lit briefly then went off
Same as others.
1. Unplug dryer from power source
2. Use nut driver to remove two front screws at bottom of dryer
3. Disconnect cable connected to Secondary Coil (this is the coil towards the rear of the dryer)
4. Use angled phillips screw driver to loosen screws holding cap on top of the two coils. (Angled tool not required but seemed easiest to me)
5. Slide top cap back towards lock screw to allow coil to be lifted out
6. Remove and replace secondary coil
7. Replace cap, tighten screws to lock in place, reconnect cable to coil
8. Restore power to dryer, test and confirm gas flame stays lit
9. Replace lower front panel on unit

PartsSelect a great resource to use for home repairs like these. My first time using site and doing this type of work, now PartsSelect my first source to go to on such items.
Parts Used:
M Series New Style Coil Kit
  • William from Chicago, IL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers
5 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
No Heat sometimes, But for a moment then None
First and Foremost i was told that my problem was with the Thermal Fuse (Fix Ya.com), Then with the little Electrical knowledge I have thought Fuses don't turn on and off,If the fuse was bad i would get No Heat. (Even for a second) Fuses just don't turn on and turn off intermittently,when they go there done! So after a little research i decided to order the gas coil valve. I tilted the top up, two screws on the front panel, took that off and the valves were exposed,(bottom left) two screws too remove bracket then installed new coils on bracket,put back together and I Have Heat Again! NO problems what so ever since new install. I would say having not been for cleaning lint build up inside the machine (been 6 years) the Whole project took me Ten Minutes.
Parts Used:
M Series New Style Coil Kit
  • Scott from Sacramento, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
1`) broken blower motor drive belt,2) blower moter drive belt pulley loosened & seperated from shaft
1) Unplugged unit & used the 5 in 1 tool to disengage top panel clips from top of front panel & tilted top panel up & out of the way, .
2) Disconnected electrical connection @ upper right of front panel, Used drill & 5/16" socket & adapter to remove 2 upper front panel screws on backside of panel & removed panel.
3) Removed 4 screws from lint screen duct, unplugged elect. con.@ the right & removed lint screen & duct from dryer bulkhead..
4) Loosened 2 top screws & removed 2 bottom screws from bulkhead & lifted bulkhead up & out & set aside.
5) Slid drum belt off the back of the drum & removed the drum
6) Ceaned the blower moter drive shaft threads & threads inside the shaft pulley. Used a file to clean up any burrs on shaft pulley, coated treads of pulley & shaft with red lock tite thread dressing & re-instaled pulley back onto shaft with ajustable pliers while holding blower fan blades steady from inside the blower motor housing. with other hand. note: (pulley is left handed thread)
7) Looped new belt onto drive motor pulley then worked it back onto blower moter pulley with one hand while turning the blades of the blower from inside the blower housing with other hand until it was back in place & ribs on belt were seated in the mating ribs of the pulley.
8) Put everything back in reverse order with the exception of removing the back panel to reinstall the drum belt onto the drive motor shaft pulley and tensioner @ bottom left in back of the dryer.

Hope this instructional is able to help some one else & good luck with your projects!
Parts Used:
Blower Belt
  • Tim from DUNCANVILLE, TX
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers, Socket set, Wrench (Adjustable)
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
door would not latch
removed old latch with pliers - inserted new latch
Parts Used:
Door Catch
  • Paul from BENTONVILLE, AR
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Very noisy from support wheels
Changed all 4 drum support wheels and belt tension arm
Parts Used:
Idler Pulley Wheel and Arm Dryer Drum Support Roller
  • Steven from WICHITA, KS
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Socket set
6 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The dryer would not heat up
After opening the bottom access panel, I found a lot of lint build up which is very flammable. I took my leaf blower and cleaned it all out. Then I just followed the instructions that came with the part. But be careful as the igniter is fragile. I broke the first one...
Parts Used:
Igniter Kit
  • William from Canyon Country, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Wrench set
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
My drier would start create heat,than stop heating after 8-10minutes.
After reading the many different common stories,I replaced both coils (m series).Very simply lifted up the top of driver,held by 2 snap springs and 2 lint vent screws.Removed front cover,2 screws and 2 bottom snaps,coils down on bottom left.r/r both coils,reinstalled covers and let there be heat!This website is a blessing!!
Parts Used:
M Series New Style Coil Kit
  • Tom from Schaumburg, IL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Dryer heat would go off and timer would not move. Dryer would continuously run
Replaced coils on gas valve.
Parts Used:
M Series New Style Coil Kit
  • chuck from smithtown, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Too much drying time, not hot enough
I removed the Drier Door and removed the Front Drier Panel exposing the Gas Valve & associated parts. I removed two (2) screws holding the Gas Valve Coils in place & replaced the 2 terminal coil, then replaced the screws, Front Cover & Drier Door. I liked the results so much, I ordered the other Gas Valve Coil and will replace it also when it arrives.

Good trouble shooting information.
Parts Used:
M Series New Style Coil Kit
  • John from Floyd, VA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Dryer would shut off mid way through cycle and give an E1 error code
After turning off the power to the dryer I removed two screws to the bottom front panel and droped it out of the way. I remved three screws hloding the lint screen in place just for better axcess to the element. I then removed the two wires attached to the element and then the two screws holding the element in place. I put everything back together in reverse. I also took the time to clean any dust and lint out.
Parts Used:
Thermostat, Internal-Bias
  • Dwayne from Bainbridge, PA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Socket set
5 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
ignitor failed to ignite gas or would fail to after first ignition.
Watched youtube video to problem shoot. Cause determined to be coils bad. Searched web found Parts Select to be easiest site to deal with and had coils for best price. Followed instructions supplied with parts. Dryer works like new.
Parts Used:
M Series New Style Coil Kit
  • CHUCK from HARDIN, KY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
4 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
dryer would light up gas coil bad
took 2 screws out and replace new coils
Parts Used:
M Series New Style Coil Kit
  • Louis from CHARLES CITY, IA
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
YouTube video dated 9/28/2015
How to repair E1 error/fault on Whirlpool Duet dryer model GEW9200LW0 please watch that video very helpful.
Parts Used:
Thermostat, Internal-Bias
  • Madeline from PANA, IL
  • Difficulty Level:
    Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers, Socket set, Wrench (Adjustable), Wrench set
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Dryer would not start, showed F40 code
Very easy do it yourself repair, and saved at least $300.00. I watched a video and it took me less than 20 minutes to complete repair. Part fit perfect and I have already ordered another to keep as a spare.
Parts Used:
Disposable Thermal Fuse - Two Terminal
  • Glenn from KINGSPORT, TN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Dryer drum turned hard because rollers were worn
Remove top, front and drum. Top is removed by sliding a putty knife under the front corners and pushing the tabs back. Front is held with screws. Disconnect two electrical connectors. Rollers are easily accessible and changed.
Parts Used:
Dryer Drum Support Roller
  • Paul from STONE CREEK, OH
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!