dryer would't heat up and noticed a smell of something very hot just prior to dryer not heating up.
Prior to ordering parts i moved the dryer out and took the back off the dryer with a nutdriver. I noticed right a way the heating element was damaged and burnt up. I ordered the above parts and recieved them in two to three days. the parts on my dryer were easy to get to and I just matched up the parts i recieved and replaced them one at a time. It only took a nit driver to remove them and plug the wires back in to the new parts.
the dryer works like new again.
Parts Used:
Dryer Thermal Fuse Dryer Cycling Thermostat Heating Element - 240V 5400W Thermal Cut-Off Kit
  • larry from decatur, IL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
12 of 25 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
bad heating element
Pulled the dryer away from the wall took back cover off the dryer. Used volt/ohm meter to identify the bad element. Ordered the element it came in two days. 2 screws and 2 wires to plug in and we were back to drying cloths
Parts Used:
Heating Element - 240V 5400W
  • Kevin from pendleton, IN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Dryer would not heat up
Un plug or remove power before you start. First you would have to remove the rear panel of the dryer. All you need is a quarter inch nut driver. Then look at the bottom right side of the dryer. There you will see the heating duct. At the very bottom is where the element is. There are two screws on both sides( they will all be removed with a quarter inch nutdriver ). After you have removed the four screws holding the element on you will have to remove two wires from the elemet be sure that you mark them and dont mix them up. You will also have to remove the round temperature sensor because you will have to reinstall it on the new element. Then you get new element and reverse the order of my directions. Good luck and be safe ALL WAYS REMOVE POWER BEFORE WORKING ON ELECTRICAL APPLIANCES.
Parts Used:
Heating Element - 240V 5400W
  • Clinton from Warren, AR
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers
6 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Dryer was blowing cold air
It's amazing... I fixed my dryer!! I am a 47 year old woman with no technical training, and I did it!

I live in a apartment and I bought the Whirlpool Dryer (Model #LER7646JQ0) USED for $150 about 6 months ago. The dryer started blowing cold air, so I called the place that I bought it from and they quoted me a price of at least $300 to fix the dryer.

After searching through google, I found the partselect.com website, and read the repair stories. I decided to take a chance. I ordered just 2 of the suggest 4 parts that could fix the issue, and the dryer did not work. The next day I order the other 2 parts, and that did it - my dryer was fixed.

The diagrams on the site were a little confusing to me (the dryers looks a little simpler inside) but it was easy to repair. I used a screw driver and plier to do the repair, however it would have been much easier if I had a socket set. I would suggest buying all parts suggested, and return the items you don't need. Here are the parts I used:

1. THRMST-FIX (Thermostat, High Limit 221 F
2. USE WPL 279838 (Heating Element (10" long x 6" wide)
3. Thermal Cut-Off Kit
4. Cycling Thermostat (Limit: 155-25) (Thermostat, Internal-Bias)

Good Luck!
Parts Used:
Dryer High Limit Thermostat Heating Element - 240V 5400W
  • All About Eve from Hollywood, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
6 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
dryer would not heat
thought the heating element was bad, once inside the element
looked good, tested continuity , tested good.
further test revealed I only had 110 volts at the wall outlet,traced problem to fuse blown in disconnect box under
the house.
Did not need the heating element.luckily parts select is taking the new element back since I did not use it.
Hope this review helps.
Parts Used:
Heating Element - 240V 5400W
  • Jessica from Campton, KY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers
6 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Dryer would not stop. Heating problem also fixed
Followed the video .... Also installed another part. which was a kit. the video here showed the third wire being installed. The video on repair clinic did not show where to attach the third wire (orange wire). The Kit and the Thermostat was installed with 25 mins. Thanks
Parts Used:
Dryer Thermal Fuse Dryer Cycling Thermostat
  • Frank from Wingdale, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
7 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Heating Element went bad, melting a wire
*as with all electrical repairs I unplugged dryer from the outlet*

I disconnected the wires to the heating element, removed the 2 nut screws holding the heating element in place and removed the defective heating element. It looked like the heating element had darkened on the lower end and the wire terminals definitely looked like they had built some resistance that lead to the connection wire melting.

I slid the new heating element in and replaced the 2 screws. I cut the melted portion of the connection wire about 1/2" beyond the melted area and stripped the wire jacket exposing clean wire. I took the connection kit & clean wire lead, divided the wires into 2 groups on each end and braided them together and twisted them to a hand tight grouping. I then took the lead cap and twisted into onto the braided wire connection until it was also hand tight and snug.

I then reconnected the heating element connection wire back to the terminal end of the heating element and made sure all connections were snug.

I plugged the dryer back in, reset the dryer by turning the dial to a timed setting then back to off. I set the heat to low turned the dial to a time dry and turned on the dryer to ensure the element heated up and that the wired connection was secure. After 20 - 30 seconds, the element maintained heat and no issues were found with the fixed wire.

I replaced the dryer back and all screws and reconnected the vent hose. Dryer has worked great for the last few weeks with no issues. I was really surprised it was that easy to fix.
Parts Used:
Heating Element - 240V 5400W Heating Element Connection Wire Kit
  • Ryan from INDIANAPOLIS, IN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
No heat on any applicable settings
Cleaned entire unit, replaced all thermostat assemblies and exhaust seal
Parts Used:
Dryer High Limit Thermostat Lint Trap Housing Seal Dryer Cycling Thermostat Thermal Cut-Off Kit
  • Russell from LOUISVILLE, KY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Dryer quit heating
I removed the hex head screws from the back of the dryer and removed the back panel, after unplugging the dryer. I tested the various electrical components until I found that the upper limit temp fuse had gone out. Came to partselect.com and found the kit I needed and ordered it. When it came in, I replaced the upper temp limit fuse, and the other parts that came with the kit. I also, since the back was open, used the opportunity to vacuum out the blower fan and as much of the lint as I could get to. Dryer works great now!
Parts Used:
Thermal Cut-Off Kit
  • Christopher from Orlando, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
6 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
No heat, everything else worked fine.
Installed the new High Limit Thermostat onto the new Heating element and installed the unit on the dryer. Wires were then connected and the dryer was tested. Repair complete. Dryer is 25 years old and this is its first repair.
Parts Used:
Dryer High Limit Thermostat Heating Element - 240V 5400W
  • STEVEN from MORA, MN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Dryer would leave clothes damp
First, I unplugged the dyer and then I removed all of the screws for the panel that covers the rear of the dryer. This exposed the cycling thermostat's location. I then removed the wires, one at a time so I would be able to put them back on in the same place. Then I removed the one screw using a nut driver and then put the new cycling thermostat in place. It was pretty easy.
Parts Used:
Dryer Cycling Thermostat
  • Luke from Elmira, NY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
5 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Clothes not drying, and dryer didn't get warm.
Good
Parts Used:
Heating Element - 240V 5400W Heating Element Connection Wire Kit
  • Steven from WINSTON SALEM, NC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
5 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Poor drying and took excessive amount of time to complete partially dried loads
Took back cover off. Cleaned out the lint that had built up inside the dryer. Replaced the lint trap housing and lint chute seals. Also replaced the drying vent hose. Works great now.
Parts Used:
SEAL Lint Trap Housing Seal
  • Stephen from LOUISVILLE, KY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers, Socket set
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
My dryer stopped heating
The repair was really easy and I loved the DIY videos they were great, not many tools needed to do these repairs that was great. The only thing is this didn't solve my issue.
Parts Used:
Dryer Thermal Fuse Heating Element Connection Wire Kit
  • Jennifer from CLINTON, MS
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
5 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Dryer too hot in all heat settings.
My dryer was running way too hot and the temperature settings didn't make any difference. Clothes were shrinking and coming out almost scalding hot. I followed simple directions posted on you tube for troubleshooting this problem. I checked that there were no lint blockages, visually inspected all connections and hardware. All seemed good. Metered out all thermostats and fuses. Everything checked good for continuity. For the reset-able thermostats, I heated them on a hot plate to verify that the normally closed switches opened near their specified temperatures. Dont do this for the non-resetable fuses and thermostats. If you're
not sure, avoid this step. Only the hi-limit thermostat seemed to open a little higher than expected but I couldn't with 100% accuracy determine the exact temp it opened. Made sure the heating element wasn't shorted in its housing or that too might give the dryer the same symptoms. That checked good too. Only thing left I could think of was to change that hi-limit thermostat. Ordered part, removed and replaced. Perfect fit. Op-checked good. All heat settings now operate normally. No more shrunken clothes that are too hot to touch even on the lowest setting lol. Hope this helps, happy hunting.
Parts Used:
Dryer High Limit Thermostat
  • Jon from SALINAS, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers
4 of 4 people found this instruction helpful.