the light socket broke apart
I took out the old socket by moving a clip. Reattached the electrical wires, clicked in the socket and that was it.
Parts Used:
-
Elyse from Skokie, IL
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers
4 of 7 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Cracked Icemaker Water Fill Tube
The plastic part that connects the fresh cold water to the ice maker in back of the fridge cracked.
Do to the fact that Whirlpool has the part stick out on the back top part of the fridge. So if you push the fridge just an inch too far back the plastic part will crack.
I ordered (The Part S&H)- came to about, $11.00.
1. Turned off the cold water under the sink.
2. In the back of the freezer section. I unscrewed the two screws that held the old broken part to the fridge.
3. I opened the freezer section and cleared out the top shelf till I could see the back of the fridge.
4. I removed the old plastic part by pushing & wiggling it about forward and it then extended out the back of the freezer side and then I pulled it out the back and it came out.
5. I slid the new replacement part in basically the reverse of step 4.
6. I connected the hose in the back. To the new, replacement plastic part, that fills the automatic ice tray with water.
7. Once finished I glued a small 2”x2” piece of wood next to the new part so the fridge will never get too close to the back wall so to never break that part that sticks out again.
Before just a small bump could break the part and water is everywhere and this leak could happen slowly at first and the next day what a mess.
Some fridges have this part recessed into the back of the fridge so this would never happen as my other fridge has.
Also, this might seem like more work then it was. It was very simple. I was scared I'd screw it up, but just did it step by step. If I had someone do it. It would have cost me a bundle.
It took more time to type this, then to do the work.
I had no instructions to follow, but again, was easer then I thought it would be.
I hope that this was helpful,
Jim Vourakis
Do to the fact that Whirlpool has the part stick out on the back top part of the fridge. So if you push the fridge just an inch too far back the plastic part will crack.
I ordered (The Part S&H)- came to about, $11.00.
1. Turned off the cold water under the sink.
2. In the back of the freezer section. I unscrewed the two screws that held the old broken part to the fridge.
3. I opened the freezer section and cleared out the top shelf till I could see the back of the fridge.
4. I removed the old plastic part by pushing & wiggling it about forward and it then extended out the back of the freezer side and then I pulled it out the back and it came out.
5. I slid the new replacement part in basically the reverse of step 4.
6. I connected the hose in the back. To the new, replacement plastic part, that fills the automatic ice tray with water.
7. Once finished I glued a small 2”x2” piece of wood next to the new part so the fridge will never get too close to the back wall so to never break that part that sticks out again.
Before just a small bump could break the part and water is everywhere and this leak could happen slowly at first and the next day what a mess.
Some fridges have this part recessed into the back of the fridge so this would never happen as my other fridge has.
Also, this might seem like more work then it was. It was very simple. I was scared I'd screw it up, but just did it step by step. If I had someone do it. It would have cost me a bundle.
It took more time to type this, then to do the work.
I had no instructions to follow, but again, was easer then I thought it would be.
I hope that this was helpful,
Jim Vourakis
Parts Used:
-
James from Ft. Lauderdale, FL
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Pliers, Screw drivers
4 of 7 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water fill tube broken
removed two screws and pulled part out of the unit. The local appliance store said they needed model and part # to try to identify and order the part. Found part select online, found the part immediately, ordered the part for $4.50 or so. Part was delivered in 2 days! Very easy installation and the part works perfectly. Thanks so much!
Parts Used:
-
Jeffrey from Monroe, MI
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Screw drivers
3 of 4 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Cimpressor would not start
Checked compressor with amp meter, and found it was not running, found Overload Switch bad.
When removing old switch watch carefully which lug you move wires from, so you will know which
lug to put the new switch on.
BE SURE YOU KNOW SOMETHING ABOUT
ELECTRICITY!!
When removing old switch watch carefully which lug you move wires from, so you will know which
lug to put the new switch on.
BE SURE YOU KNOW SOMETHING ABOUT
ELECTRICITY!!
Parts Used:
-
Oliver from Madison, AL
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Nutdriver, Screw drivers
5 of 11 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Bad fan motor
Pop off six mounting screws and the ground screw. Remove the fan blade and reattach. Reinstall. Save yourself big bucks.
Parts Used:
-
Mark from Farmington Hills, MI
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver
3 of 5 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Faulty light socket
-
Larry from HOUSTON, TX
-
Difficulty Level:Very Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers
3 of 5 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broken plastic part at top of water fill tube to freezer
Simple. 1st, removed broken part to understand part (water fill tube to freezer, plastic part at top of fill tube cracked). 2nd go on your web site and look at prints to find part number, Study video to understand video. 3rd. Called customer service and lady was very nice and efficient. Placed order and received. Study video again and installed. My 9 year old grandson was visiting from out of town and assisted in installation. Just over 30 minutes to install
Parts Used:
-
Jay from Mt. Pleasant, WI
-
Difficulty Level:Really Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Screw drivers, Socket set
2 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Mounting bracket was riveted on old motor, mounting bracket holes on new motor were different
removed shims on screws holding motor together, enlarged hole in mounting bracket so motor screws could also go through mounting brackets.
Parts Used:
-
MIKE from ARLINGTON, OR
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:1- 2 hours
-
Tools:Nutdriver, Screw drivers
2 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fan was noisy - bearing had failed
It's self-explanatory. The procedure is obvious; it's just a little difficult. The only hard part is attaching the mounting brackets to the fan. If you can't tighten the mounting bolts, loosen them and reposition the brackets. You might end up mispositioning them at first, because they are hard to reach.
Parts Used:
-
Karl from Wellesley, MA
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver
2 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
freezer (later fridge too) wouldn't stay cold~
****Make are you order Capacitor & Starter relay too (we ordered separtely so had to pay shipping twice)**** Super easy just open access panel on back near compressor and remove retention clip with fingers, remove & replace both capacitor & starter, put clip and access panel back on, plug in and allow 8 hours to cool! Works like new again! Hope it goes another 10 years
Parts Used:
-
David from MARYLAND HTS, MO
-
Difficulty Level:Very Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver
2 of 3 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
replacing evaporator fan
My fridge did not have icemaker add on. The evap fan is in the freezer behind the back panel. Empty the freezer section (into a cooler) and turn the fridge off. Remove all the shelves in freezer section. Remove the shelf support tabs by lifting them up. use phillips head screwdiver to remove back panel in freezer section. Use nut driver to remove fan shroud. Remove old fan and save the mounting arms. Install mounting arms on new fan and install fan. Install shroud, back panel, shelf mounts and shelves. Thats it!
Parts Used:
-
Steve from SAN CARLOS, CA
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver, Screw drivers
2 of 3 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Outer case of freezer was heating up, not making ice (sometimes) turned up thermostat several times (especially freezer)
I got the product very quickly. (thank you) Looked at online instructions that were quite vague. Pulled plug.Removed the holder for the fan motor slid it out to see what I had. Removed the mounting screws (3) and slid the motor an fan blade out. I made a cut between the wires and marked the "top" wire to motor to be sure to spin in right direction. Removing fan blade hold down clamp was NOT explained at all but I noted that the shaft on the motor was threaded, so I used pliars and held the shaft white un-screwing clamp. I cleaned the fan blades with degreaser and scraped edges of opening on holder opening. Make sure to use ALL the NEW parts included with this kit when re-installing. They send them for a reason. When slpicing and connecting wires it is a 50/50 shot if you don't mark before cutting. You can connect and try plugging fridge back for moment and make sure it is blowing OUT. Put everything back together and after turning DOWN the thermostats twice, fridge is back to usual. Ice maker is cranking out ice and outside case is cool to the touch.
Note: This can be a DIRTY job especially with 4 dogs in house. Fir and grease don't mix well
Note: This can be a DIRTY job especially with 4 dogs in house. Fir and grease don't mix well
Parts Used:
-
John from Greensboro, NC
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver
3 of 6 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
noisy fridge, perimeter of door heating up
figured out the condenser fan was kaput. Tried WD, worked for several days then gave out completely. Took off back of fridge and trained small fan on compressor while I ordered new condenser fan. The swap was easy, undid the housing bolts, stripped off the connector, reconnected and voila! works perfect.
Parts Used:
-
craig from maple grove, MN
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver, Pliers
2 of 3 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Shelves in freezer falling off
Went online with the model number, the part was very easy to find, diagrams helped me to have confidence in the choice. Parts came in two days, tore them open and used a screw driver to replace the broken shelf brackets, replaced shelves, I am a happy camper!!
Parts Used:
-
wendy from palm coast, FL
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Screw drivers
2 of 3 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The plastic water fill tube got cracked when we moved. I called a parts company and they told me they couldn't just sell me the tube I would have to buy a whole kit for about $50 dollars. I decided to glue the tube. It worked for a while then it started leaking. So I thought I would have to buy
I hand screwed the fill tube into the water tube and stuck it into the freezer hole. I screwed the fill tube to the back of the refrigerator.
Thanks so much! You saved me a bundle!!
Thanks so much! You saved me a bundle!!
Parts Used:
-
Joseph from Chesterfield, MO
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Screw drivers
3 of 6 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!