Freezer was too cold and refrigerator was too warm
After receiving the part, I watched the installation video on the PartSelect website. The step by step demonstration was excellent. I felt confident I could do it myself after watching the video just once, and utilizing the written instructions that came with the part. The installation went smoothly, and my refrigerator is functioning correctly again. Best of all, I did not have to go through the hassle and expense of hiring a repair person!
Parts Used:
-
Jolinda from Eau Claire, WI
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers, Socket set
Was this instruction helpful to you?
Thank you for voting!
Refrigerator not cooling
Exactly how the part select video described it. Threw a little curve ball figuring out which timer setting to set it to. But the instructions provided with defrost timer walked me right through it. No problem. After installing part nothing happened for about ten minutes, which had me second guessing each and every step. Then, like magic, cold air began blowing. What a relief. Thanks so much, love this site. Refrigerator works like new!
Parts Used:
-
Bryan from Midland, NC
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver, Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
See below
The defrost timer that I ordered form you did the trick. My fridge was
running all the time and the fridge temp was 55 but the freezer was 10
below. The instructions did not say how to test the old one to compare with
the new on. However in the Readers Digest Home Repair book it did and the
test proved that it was defective. Your article said that with the system I
had, 65% on the time it was the timer. I ordered it and thank you it works
just fine. I do have another problem, maybe you can help. The fridge runs
for 6 minuets and stays off for 10 minuets. The temp in the freezer is 0
and the fridge is 35-40 on the warmest settings, but all is well.
Thank you
running all the time and the fridge temp was 55 but the freezer was 10
below. The instructions did not say how to test the old one to compare with
the new on. However in the Readers Digest Home Repair book it did and the
test proved that it was defective. Your article said that with the system I
had, 65% on the time it was the timer. I ordered it and thank you it works
just fine. I do have another problem, maybe you can help. The fridge runs
for 6 minuets and stays off for 10 minuets. The temp in the freezer is 0
and the fridge is 35-40 on the warmest settings, but all is well.
Thank you
Parts Used:
-
Patricia from Hobe Sound, FL
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Fan motor worn out
My Son who is not an appliance repairman did it for me. He had some difficulty getting the nuts and bolts loose mainly. Sorry I'm not much help other than that! I would like to compliment you on your fast service, first time ordering from you and it was for an older model refrigerator that my repairman said he couldn't find. It's working fine now and I'm a satisfied customer!
Parts Used:
-
Myrna from Decatur, IL
-
Difficulty Level:Difficult
-
Total Repair Time:1- 2 hours
Was this instruction helpful to you?
Thank you for voting!
wouldn't make ice, door seal was hot to touch, warm in fridge.
I folded in half twice! and took the back off the fridge(cardboard) and took one brace off and just took the screws off the fan from the other two braces. Turned the fan enough to get at the wires for the fan and cut them off an inch from the old fan, stripped the insulation and wire nutted them to new fan. Make sure they don't interfere with the new fan and put the new fan in place put the screws in and we're making ice and cold fridge again.
Parts Used:
-
Dale from Sterling, AK
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:1- 2 hours
-
Tools:Nutdriver, Socket set
Was this instruction helpful to you?
Thank you for voting!
The old gasket had worn out.
I was really surprised. It was easier than I thought. Once I l loosened bolts with nutdriver the old gasket came out with no problem. To put the new gasket on I started at the top. I just slid the gasket lip under the metal brackets on the top and then the bottom. Next I slid the gasket lip under the metal brackets on the sides. I started tightening the bolts on the top and then the bottom. I did the sides last. I don't know about you but I had set aside the whole day for this and it only took 2 hours.
Parts Used:
-
Judith from Charlotte, NC
-
Difficulty Level:Easy
-
Total Repair Time:1- 2 hours
-
Tools:Nutdriver, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Evaporator fan motor stopped working
Remove back cover of freezer compartment; Remove old fan assembly, new fan terminals did not exactly match old one so I had to remove one of the terminals from old fan and attach it to new fan/ then install new assembly and repaced freezer cover
Parts Used:
-
Kurt from Baltimore, MD
-
Difficulty Level:Difficult
-
Total Repair Time:1- 2 hours
-
Tools:Nutdriver, Screw drivers, Wrench set
Was this instruction helpful to you?
Thank you for voting!
Fan was making noise, Freezer temperature was erratic
First, watched video on Part Select Website. Very good. Pulled Appliance out from wall, Pulled the power plug, and removed the back shield covering the working parts of the unit. Found the fan and it was almost the same setup as on the video except that I could not get to one of the screws holding the motor in place so had to remove the entire bracket with the fan. Not too hard. Cleaned away dust and gunk around the site and noticed that the fan pulled air through a tunnel-like condenser coil that was packed with gunky lint...this is what probably killed the motor. I cleaned out the tunnel with the bottle brushes and vacuum and installed the new motor / bracket assembly. Then replaced the shielding around the fan and the back cover .panel. This is important because these form the channel that guides air flow throughout the condenser coils. This particular refrigerator has a barrier underneath which guides air flow from the front left to the condenser, through the fan, over the evaporator drip pan and out the right front. I cleaned all the lint and gunk from this area as well. I also made an air filter (cut from a furnace filter) and wedged it in front of the air entry section. This should keep the condenser coil cleaner over time but you have to remember to change the filter once a year. Probably should clean the condenser coil every 5 years as well. This unit has been very reliable over 20 years and may well go for another 20. Good luck with your repair.
Parts Used:
-
Dik from Quincy, MA
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:1- 2 hours
-
Tools:Nutdriver, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Refrig ran and ran with a lot of hot air coming from the back. Temps in freezer and refrig areas would fluctuate with the unit running almost constantly. Discovered the fan was intermittently running, mostly not.
Removed the old fan; cut the wire and spliced in the new fan and reassembled. A little over one hour. Refrig is working perfectly now with lower settings. It is definitely off much more than on now.
Parts Used:
-
Donald from Strafford, NH
-
Difficulty Level:Easy
-
Total Repair Time:1- 2 hours
-
Tools:Socket set
Was this instruction helpful to you?
Thank you for voting!
blower motor was going out
just had to remove the fan motor the hard thing is getting down to it
Parts Used:
-
Robert from Batavia, OH
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:1- 2 hours
-
Tools:Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Refrigerator not shutting off, liquids freezing in fridge
It wasn't quite as easy to get to the bolts as the video showed. The lay out of the part wasn't exactly like the video either. However, I managed to put the new part in. Unfortunately, it didn't solve the problem. At first the fridge cycled on and off but after 12 hrs it started to freeze liquids again. Since the appliance was 17 years old we opted to just get a new one.
Parts Used:
-
Barbara from Apollo, PA
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:1- 2 hours
Was this instruction helpful to you?
Thank you for voting!
Freezer not cooling. Temperature rising.
One day the ice cream in the freezer seemed mushy, but the ice was still frozen. There was not water in the ice bin. However, the problem resolved itself. This suggested that the defrost timer had become stuck for an extended time, but then continued to run. The fact that the freezer went back to frozen, implies that all the components of the cooling loop (compressor, condenser & fan, evaporator & fan) were fine. It was possible that the problem was caused by a bad defrost (?evaporator?) thermostat but everything I saw on line suggested that the defrost timer is the culprit about 40 - 50% of the time. Anyway, I followed the instructions in the on-line video at this site for replacing the defrost timer and it was easy. It would have only taken 15 minutes, but I spent a while reading the defrost timer instructions and hunting down a schematic for my refrigerator, to determine which pin the loose wire should go on.
Parts Used:
-
Jeff from Austin, TX
-
Difficulty Level:Really Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Noisy fan
Unplug the refrigerator. Remove the rear shelf supports by lifting them straight up. No tools required. Remove the screws holding the rear cover of the freezer. Use a nut driver to remove the 4 screws holding the fan housing. Unplug the wiring harness, then remove the fan and install the new one. Remount the housing, plug in the harness replace the rear cover, install the shelf supports and plug in the refrigerator. It was 30 minutes start to finish, which includes the time to gather the tools, unload and reload the freezer, and putting the tolls away!
Parts Used:
-
Harry from Cincinnati, OH
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
refridgerator was not cooling to the proper temps and finally would not cool at all
Pulled refridgerator forward away from the wall. Remove the cardboard back behind the appliance.I saw that the condenser fan motor was not working. Unplugged the appliance from the electrical outlet. Removed a 3 wire plug from the condenser fan motor. Remove 3 screws (with a nut driver) which held the condenser fan motor in place. Remove the condenser fan motor from the appliance. Looked up the part needed for repair using the appliance model number. Found which part was applicable for the appliance. Placed the order from Price Select on a Monday morning and recieved the part 2 days later on Wednesday via FedEx. The item shipped was a 2 wire condenser fan motor. Read the instructions that came with the part. Using wire cutters, cut the old 3 wire plug. The center wire is a green and yellow striped wire. Use the same colored wire that is also shipped in the box and has connectors on both ends. Cut one of the connectors off and use the wire strippers to remove plastic wire coating. Connect both ends from the appliance and the green and yellow wire that was shipped. Use a wire nut (also shipped in the box) to connect the wires. You will have 2 black wires left on the new condenser fan motor that need to be connected to the appliance. You should have an orange colored wire and another wire that is black with a white stripe. Connect one wire from the new fan motor to the orange wire and use a wire nut to attach both wires together. Use the other black wire from the new fan motor to the black/white striped wire from the appliance. Use the wire nut to attach both those wires. Place the new condenser fan motor back in the appliance using the screws that come with the motor. Attach the green and white wire with the connector on the end to one of the 3 screws that hold the motor in place and secure the screws. Use the electical tape to hold the wires all together and away from the fan motor. Plug the appliance into the outlet. You can see the condenser fan motor working properly. Note that when connecting the 2 black wires from the new condenser fan motor to the orange and the black/white wire from the appliance, for my appliance, it did not matter which wires were connected as the fan motor was a clockwise motor. Place the cardboard appliance backing, back on to the appliance and push the refridgerator back in place. Allow about 5-6 hours to get the freezer to between 0-5 degrees. The refidgerator should be between 34-38 degrees and will take a little longer to get to that projected temp.
Parts Used:
-
John from LAS CRUCES, NM
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Condensor fan motor quit working
Pulled the fridge out, Took bottom panel off. Removed 3 screws holding motor. Unplugged connector, cut wires, attached old connector on new motor. put blade on new motor.installed in fridge, put cover back on.
Parts Used:
-
David from New Albany, IN
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver, Screw drivers
Was this instruction helpful to you?
Thank you for voting!