fan motor was loud,sqeal,would not get cold
Very easy, hardest part was taking panels out of way. 20 min. to finish. After repair it works like new.About 20 years old.
Parts Used:
Evaporator Fan Motor Kit
  • Thomas from Monsey, NY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
35 of 42 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water valve failed, flooded kitchen
Turned off water supply and unplugged appliance. Removed lower panel on back of refrigerator with 1/4 " nutdriver. Then removed supply line, and line to icemaker. removed valve from back panel and replaced with new valve. wrapped water connections with teflon tape, turned on supply line, checked for leaks, everything o.k..Replaced back panel and in 45 minutes had first drop of ice. Job requires moderate mechanical ability and minimum tools. Saved a PANT load of money by doing it myself. VERY satisfied with Partselect.com
Parts Used:
Single Outlet Water Valve Kit
  • James R from Valley Springs, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Wrench (Adjustable)
28 of 29 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The light switch on the refridgerator broke - no light.
Once I saw the replacement part I understood how to pry out the switch with a small screwdriver. Then just unplug the old one, plug in the new one and pop it into place.

The PartSelect site made it easy to correctly identify the correct part, it was inexpensive, and the shipping was fast.

I'm very pleased!
Parts Used:
Refrigerator Door Switch
  • David from Albany, OR
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
34 of 52 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator stopped cooling. Pulled it out of the alcove and plugged it back in. Compressor starfted but noticed condenser fan was not turning. Unplugged fridge and tried to turn the fan by hand - frozen.
Remove the back hardboard cover screws for access to the condenser fan. I opted to tip the fridge over on its side for even better access to the fan mounts and wire. Replaced the fan assy (reused the fan). Splice the wire and it's done.
Parts Used:
Condenser Fan Motor Kit
  • Florentino from Windsor Locks, CT
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
27 of 36 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer and Fridge wouldnt cool
My husband replaced the condenser fan. It took awhile and a few choice words but he got it replaced. The fan seemed to work fine, but it still wasn't cooling. I noticed that when we had the fridge unplugged that water started draining out the dials at the top of the fridge under the freezer. And there was absolutely no water at all in the drip pan under the fridge. So I took the doors off and totally took the inside of the freezer apart. I discovered that the styrofoam on the floor of the freezer had become inudated with fluid and the under the foam the coils were all frozen solid with ice. Hence not allowing any drainage. I put a lamp in the freezer area and defrosted all the ice. In searching the internet i discovered that they no longer produce the foam so i went to home depot and got a piece of foam and aluminum foil and cut it to replace the ruined foam. I put the fridge all back together said a prayer and crossed my fingers and lo and behold it works perfectly now!!!!
Parts Used:
Condenser Fan Motor Kit
  • Janet from Hillsboro, OR
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Nutdriver, Pliers, Screw drivers, Socket set, Wrench (Adjustable), Wrench set
23 of 24 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer too warm; noticed sides of refrigertor were warm
I saw on a partselect web site that these symptoms could be caused by a failed condensor fan motor. After removing the cardboard panel in back of the refrigerator I noticed the fan was not running when the rfigerator was. The fan was held in place by three brackets. I unscrewed the screws holding the fan motor to the brackets and also unscrewed one of the brackets to make room to pull the motor out. I cut the wires close to the motor. I removed the fan blade and secured it to the new motor. I had to reroute the old wires in order to have enough slack to use wire nuts to attach them to the leads on the new motor. I then re-attached the motor to the two brackets remaining in place and then re-attacehed the third bracket I had removed to get the motor out.. The most difficult part was working in a very confined space.
Parts Used:
Condenser Fan Motor Kit
  • W from Nellysford, VA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers, Socket set, Wrench set
22 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The old motor wouldn't turn the fan.
After moving the refrigerator away from the wall I removed the cover on the lower back of the unit by removing the screws that held it in place. The condenser fan was not turning and there was heat build up in the area causing the refrigerator to not work properly creating elevated temperatures in both the freezer and regrigerator. Removal of three torx screws from the original motor was all it took to get the motor free. By turining it and working the fan blade around the mounting bracket I had the motor out in just a few minutes. Replacing the new motor was just as easy to reinstall. The fan was removed from the old motor and placed on the new for installation. The original motor was wired to accept a connector from the wiring harness of the refrigerator. I simply cut the connector off the wiring harness and stripped the insulation from the wires which easily allowed me to connet the wires of the motor and harness with two wire nuts. Three self tapping screws were used to hold the motor in place replacing the torx screws. Installed I plugged the unit in and immediately the fan started spinning as the unit came to life. Cleaned and replaced the cover over the back and slid back into its spot. Running as good as it did when it was new. Easy job to take care of.
Parts Used:
Condenser Fan Motor Kit
  • Bob from Hesston, KS
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Socket set, Wrench set
24 of 31 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
refrigerator would not keep running.I had to tap the cold control with the blunt end of a knife
first I unpluged the refrigerator, then removed the nob for the cold control thermostat. then I removed the plastic cover, and removed the lightbulb. this revealed the metal plate that holds the cold control. four screws held this in place.once theplate was loose I unpluged the three wires that plug into the cold control, and removed the two srews that held it in place. then I remved the cold control thermostat, replaced it with the new one hooked up the wires, replaced the metal plate and lightbulb,and the plastic cover. plugged the refrigerator back in, and turned it back on works great now. I hope this will help others to make their repairs easier thanks, gary
Parts Used:
Cold Control Thermostat
  • gary from fort bragg, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
23 of 28 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Over flowing Icemaker
Ice Maker would seem like it was the valve was leaking and Ice would build up at the rear of tray.
After listening to it cycle, (drop ice and fill) valve would open up again about 20 minutes later.
Over flowed and iceberg would form at rear.
Replaced icemaker unit and works fine now.
Parts Used:
Replacement Ice Maker
  • Thomas from Flower Mound, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
21 of 28 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water began to leak under the refrigerator. Source looked like it was coming from control valve suppling water to ice maker and water dispenser.
Followed instructions supplied. It was relatively easy and the parts fit exactly right. Sears wanted twice as much for the part and service would have charged me another $100 to come to my home. I saved over $100 doing the project myself.
Parts Used:
Water Tube Kit
  • jesse from hacienda heights, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
21 of 31 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
paint on bottom of ice maker was flaking into ice
1. shutoff water
2. removed 3 screws holding old ice maker. A small nut or screw driver is needed to get into a somewhat tight area
3. detached electrical connector
4. cut indicated area for water inlet to lie in
4. attached new electrical connector (no splicing needed)
5. attached new ice maker with 3 screws
6. put on water
Parts Used:
Replacement Ice Maker
  • Richard from Newburgh, IN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
17 of 21 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Slow to produce ice & tray damage
Removed the top two screws and one on the bottom which attach the ice maker to the side of the freezer. I unclipped the wire bundle from the side of the ice maker and unplugged the connector, totally removing the unit . The maker came with several different wiring setups, but I just used the existing. The contol arm on the new unit basically snaps into place and the above process is reversed to install the new unit. My old ice maker had an accelerator which blows cold air to the bottom of the tray to speed up ice production. This component was undamaged and by taking off the new units outer end cap and borrowing the clips from the old unit, this component can be installed on the new ice maker.
Parts Used:
Replacement Ice Maker
  • Tim from Leander, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
16 of 19 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
light inside fridge was flickering and clicking
tested bulb good ,replaced door switch first(least expensive)then ordered light socket and circuitboard.If clicking sound is heard replace circuitboard first to save on return shipping because the switch and socket where ok
Parts Used:
Refrigerator Door Switch
  • bill from escondido, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
20 of 32 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer was not staying cold enugh for ice maker to work. Discovered fan was not working to cool condensor. Fan motor would only run if manually turned.
Unplugged refrigerator. Removed lower back access panels and panel running up the back of refrigerator. Removed and disconnected old fan. Removed old fan motor from mounting bracket. Removed fan blade from old fan motor and placed on new fan motor. Connected new fan motor to power supply. Tested. Reinstalled.
Parts Used:
Condenser Fan Motor Kit
  • David from Cedarville, OH
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Screw drivers, Socket set
14 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice water valve leaking
Removed two screws holding valve, removed two 1/4" water lines. disconnected wire clip from old valve.
Installed new valve, connecting water and electrical with ease.
Absolutely Simple!
Parts Used:
Single Outlet Water Valve Kit
  • Byron from Steamboat Springs, CO
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Pliers, Wrench (Adjustable)
13 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the 1066748601
16 - 30 of 508