my refrgerator stopped cooling and freezing
Take the cardboard grill off the bottom of the back it is held on with 5-6 hex head screws. Located the voltage inverter on the tank. It's on the bottom left of the refrigerator. Removed the screw that holds it in place.Remove the jumper wires at the quick connect. Rotate the voltage inverter and removed it. Check the voltage at the plug in going to the voltage Inverter. It should be 115-125 volts. Plug in the voltage inverter to the Quick connect away from the tank check the voltage on the side that would be connected to the tank. If both sides don't read at least 115 volts the inverter is bad. Order a new on and reinstall in the reverse order.
Parts Used:
-
Mike from Aguilar, CO
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver, Pliers, Screw drivers
12 of 12 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Flapper was stuck open. Old and warped.
-
James from Virginia Beach, VA
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers
16 of 27 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
slow water flow in dispenser
opened refrigerator door located water filter location in right back corner unscrewd 1/2 turn and out it comes without shutting off water it is a snap to do by anyone and shipment was really quick thanks. People do not call a service tech for something this simple even a child tall enough can do it.
Parts Used:
-
dwight from phoenix, AZ
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
14 of 21 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
filter replacement/water tray replace
remove by hand turning old and replacing new by turning by hand.Lifted out old grill and placed in new one
Parts Used:
-
ron from Winter Haven, FL
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Screw drivers
12 of 16 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice funnel cracked
Followed video for replacing the ice chute flap solenoid replacement because getting to the ice funnel took same steps of disassemble. Looked at how the existing funnel was set in the housing, where and how one spring was located, where the switch and its activating arm on the ice funnel were located, took old one out and put new one in. Cleaned everything in process.
Parts Used:
-
Jim from Glendale, AZ
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers
18 of 34 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The unit will not dispense water, but does make and dispence ice.
I replaced that part, but I still have the same problem, no water is dispensed. I believe I may need a circuit board. The problem was not the parts I replaced.
Parts Used:
-
michael from west bend, WI
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Pliers, Screw drivers
16 of 29 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
refrigerator and freezer stopped working
I replaced the three sensors, 2 in the freezer 1 in the refrigerator. This was rated as the most common problem. Did not fix the problem. I then checked the ohms on the new sensors then the old sensors they were all within .5 of each other. So I got smart and went down the list of causes on their list. I emailed partselect and asked what the parts should read. They replied with that information and it turned out to be the voltage converter on the compressor. I ordered the part on friday payed for overnight delivery and it arrived tuesday. This as you can imagine makes me angry. But the part was easy to install and my refrigerator started working right away. I would advise anyone with this problem to start at the top of the problem list use a multi meter check everything on the list and only replace part or parts that don't come up to standards. This will save time and money and hopefully fix the problem the first time as you are not switching out parts and hoping that it solves the problem.
Parts Used:
-
mike from Aguilar, CO
-
Difficulty Level:Really Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver
9 of 9 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Frig stopped working
Tested the circuits then the inverter and found that to be no good. There was no 277 voltage leaving the inverter. Ordered new and replaced. The frig is now working fine.
Parts Used:
-
Anthony from CAMBRIDGE, MA
-
Difficulty Level:Very Easy
-
Total Repair Time:1- 2 hours
-
Tools:Pliers, Screw drivers
10 of 14 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Icemaker flap not closing, frosting up
Watched video, however could not get outer casing off. Under the panel are three small holes, pushed up with an Allen key, used a small screwdriver to wedge out, came out easily, followed instructions from video on removing and replacing solenoid
Parts Used:
-
Graeme from Sarasota, FL
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers
9 of 11 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice buildup. The Ice Machine was frosting over. Ice (due to frosting) would block the drop chute.
Unfortunately, the replacement part didn't come with instructions. The repair, nevertheless, was fairly straightforward. After removing the plastic parts that guide the ice through the door (by removing a few screws that attach the parts to the inside of the door), I was able to slip my hand into the ice maker dispenser and remove the old part. The part clips on. It is a tight fit through the funnel (from the outside of the freezer), however, and requires that the gasket first be "flipped" open wherein it unfolds 180 degrees. Doing this will make it easier to clip the new gasket onto the assembly.
Parts Used:
-
Tim from The Woodlands, TX
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers
9 of 12 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker door not opening
Removed panel from front of freezer door by pushing up on three spring loaded screws located in the opening where the ice door opens and closes. they are about 1 inch apart on the bottom of the opening. Push up to free ice maker panel. Remove three screws from solenoid, located at the top right. Remove wire, replace with new and that is it. Fixed the problem!! Our ice maker hadn't worked for months. Be careful if you remove the round ice maker door to clean. There is a spring that located on the left side of sprocket. The spring fell off and took me a while to figure where it came from. Recieved package in three days and the job took minutes. Works great! Very easy to complete.
Parts Used:
-
scott from lake orion, MI
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Nutdriver, Screw drivers
8 of 10 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Compressor would not kick on and condenser fan ran constantly
Remove back panel on bottom of fridge to access compressor area. Remove screws from water solenoid and water valve and push to the side so the side of the compressor can be accessed. Then locate the inverter box. You will find a Phillips head screw on the bottom of the inverter. This is the only screw that hold the inverter in place. Remove the screw and tilt the inverter box forward away from the compressor, then lift the box out of the the holder. You may have to wiggle it a bit to get it out. Remove the plug that attaches to the compressor and then with the power on check your voltage coming to the compressor. It should read 120 volt. If it doesn’t your inverter is bad. Remove the other plug on the inverter box and pull the box out.
Reinstall the unit in reverse order. Use the appropriate jumper to plug into the wire connection going to box and then plug it into the connection off the fridge.
Once everything is reinstalled and before you put the back panel on plug your refrigerator back in and you should be able to hear the compressor working or feel the top of it to make sure. If it’s working you are good and can reinstall the back panel.
It will take 4-5 hours to come back to temp if it’s been off for any length of time.
Reinstall the unit in reverse order. Use the appropriate jumper to plug into the wire connection going to box and then plug it into the connection off the fridge.
Once everything is reinstalled and before you put the back panel on plug your refrigerator back in and you should be able to hear the compressor working or feel the top of it to make sure. If it’s working you are good and can reinstall the back panel.
It will take 4-5 hours to come back to temp if it’s been off for any length of time.
Parts Used:
-
Charles from ORO VALLEY, AZ
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver, Screw drivers, Socket set
6 of 6 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker not delivering ice, shoot freezing up with condensation.
Your video shows how to make the necessary repairs. Solenoid was the main issue, other parts were replaced to bring assembly to "like new" condition. Over kill but thats how I fix things. All and all a very easy fix. Thanks for the info and parts.
Parts Used:
-
Michael from Virginia Beach, VA
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Screw drivers
9 of 16 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Unit was not dispensing water nor ice.
Removed the plastic frame by pushing to the inside (all 4 sides), removed touch pad by sliding it to my right and disconnected the wires. Removed the four screws that hold the dispensing unit and replaced broken parts. Please note that I also replaced the funnel. Total cost of repair for DIY $30.00, savings by avoiding repair man, priceless.
Parts Used:
-
Javier from Woodstock, GA
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers
9 of 16 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Red Spring Broke - Refrig Sect. Door Closure
I found that I did not have the strength to stretch the new spring enough to install it initially. Using a 1/8 or 5/32 inch allen wrench I removed the pivot for the arm that the spring applies tension to. This allowed the spring to be easily attached to the hole in the arm and to the post in the bottom of the refridgerator. I then used a small pliers to grab the arm in front of its pivot hole and pull it against the spring into position to replace the pivot. Replacing the filter was surprisingly easy. I turned the water supply valve off under the sink and easily unscrewed the old filter (about a quarter turn). I filled the new filter with water and srewed in in. No wrenches required. I turned the water back on under the sink and everything works great!
Parts Used:
-
Jack B from Walnut Creek, CA
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:15 - 30 mins
-
Tools:Pliers, Screw drivers
8 of 13 people
found this instruction helpful.
Was this instruction helpful to you?