TMH14XLQ (AWHEEST) LG Range - Overview
Sections of the TMH14XLQ
[Viewing 7 of 7]Keep searches simple, eg. "belt" or "pump".
Light Bulb - 120V 30W
PartSelect #: PS3530415
Manufacturer #: 6912W1Z004B
$24.95
In Stock
Order within the next 1 hr and 19 mins and your part ships today!
Air Duct Bracket
PartSelect #: PS3523851
Manufacturer #: 4810W1A151A
This bracket holds the metal or plastic flapper that closes off the exhaust duct when the fan is not running and opens when the fan turns on. If the exhaust fan on your microwave does not appear to be...
$24.15
In Stock
Order within the next 1 hr and 19 mins and your part ships today!
Time Delay Fuse
PartSelect #: PS3522743
Manufacturer #: 3B74133Q
Sold individually.
$13.15
In Stock
Order within the next 1 hr and 19 mins and your part ships today!
Spring
PartSelect #: PS3524607
Manufacturer #: 4970WRA001G
This spring provides tension or controlled movement within the appliance mechanism. Engineered for durability, it supports smooth operation and helps maintain proper alignment of connected components.
$13.15
In Stock
Order within the next 1 hr and 19 mins and your part ships today!
Glass Cooking Tray
PartSelect #: PS3517413
Manufacturer #: 1B71961H
This tray rotates in your microwave ensuring more even temperatures.
$67.05
In Stock
Order within the next 1 hr and 19 mins and your part ships today!
Hardware Mounting Kit
PartSelect #: PS3522503
Manufacturer #: 3861W1A043C
$48.35
In Stock
Order within the next 1 hr and 19 mins and your part ships today!
Mounting Plate
PartSelect #: PS3518617
Manufacturer #: 3300W0A030A
$56.05
In Stock
Order within the next 1 hr and 19 mins and your part ships today!
Capacitor
PartSelect #: PS3517241
Manufacturer #: 0CZZW1H004B
$60.45
In Stock
Order within the next 1 hr and 19 mins and your part ships today!
Thermostat
PartSelect #: PS3530460
Manufacturer #: 6930W1A003E
$18.65
In Stock
Order within the next 1 hr and 19 mins and your part ships today!
Common Symptoms of the TMH14XLQ
[Viewing 4 of 4]Won’t turn on
Fixed by
these parts
these parts
Show All
No heat
Fixed by
these parts
these parts
Show All
Door not closing properly
Fixed by
these parts
these parts
Show All
Tray won’t turn
Fixed by
these parts
these parts
Show All
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Broke the round glass tray
-
Eileen from DETROIT LAKES, MN
-
Difficulty Level:Very Easy
-
Total Repair Time:Less than 15 mins
10 of 14 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Micro Wave no heat all else fine. Also at times door would not shut properly.
Replace (after testing w/ohm meter) diode and locker holder. My door often would not close properly. Microwave let know by saying not shut properly. When disassembled found the top screw mount was hollowed out resulting in it moving on occasion when you close door. First remove casing (special safety torx head) needed for rear screws. Onc e removed all parts available to view or work on. Diode is on the capacitor so caution is needed when removing. Serious shock hazard if touched. Use insulated pliers to remove from capacitor and a phillips on the ground. Test with ohm meter Should have resistance on way and non the opposite. Replaced mine bad. Next the holder 2 phillips screws and its yours. Unplug each switch and remove. Take note to what wires go to what switch and what switch mounts where. Mine had 3 switches. Removed from old holder and put in new. Screwed holder back in place and left scrws loose till re wired. Once wired set the holder by lightly tighting the screws. Try the door till it seats properly ensuring that all 3 switches are working properly. If so thighten screws. If all seems to work as advertised, safely plug in and test unit if heats up un plug and put cover back on micro. Your all set. Happy heating.
Parts Used:
-
Roy from MILLINGTON, TN
-
Difficulty Level:Really Easy
-
Total Repair Time:1- 2 hours
-
Tools:Pliers, Screw drivers
2 of 2 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Microwave operated but did not heat
Initial failure of over range microwave Aug 3rd. Control Panel worked but no heat. Took to local LG authoriaed local repair place. They fixed it quickly and we re-installed it. Worked fine for 2 months then had similar failure again. Agaim took to same authorized repairer. They kept unit for 3 months but finally concluded theu could not fix it and suggested we contact LG for a partial refund. When they tested the unit during re-assembly in my presence, there was a blue flash and the fuse blew. Since we had built a custom tile mural back splash around this unit, I brought it home, ordered a number of time delay fuses new capacitor and two new high voltage diodes. However, using my Fluke DMM, I checked the existing capacitor and high voltage diode and they checked OK so I just replaced the time delay fuse. The high voltage transformer leads had 2 possible ways to connect to capacitor and diode. Tried one way, plugged unit in and turned it on, and immediatly blew the fuse. Replaced the fuse and reversed the high voltage transformer connections,amd turned unit pn, and it worked perfectly. Since we had experienced several power failures during the time of the original failure, the repairer concluded that power spikes might be at fault, so I also purchased a TrippLite ISOBAR4ULTRA 3300 Joule surge protector between wall outlet and microwave, and re-installed over range. It has worked perfectly since.
Parts Used:
-
Donald from Oak Ridge, TN
-
Difficulty Level:Easy
-
Total Repair Time:1- 2 hours
-
Tools:Screw drivers
3 of 10 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!