broken left arm to hold rack in
Just put the two screw back in that i had removed.
Parts Used:
Gate Support - Left Hand
  • Roy L from Layton, UT
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Heard a five second buzzing sound repeated 4 or 5 times per cycle coming from rear lower left compressor side.
Removed the six screws holding the bottom access plate found at the rear of the refrigerator. This gives you easy access to the run capacitor that has a retaining clip. Remove the wire clip and pull out the capacitor (it has two quick disconnect terminals). Reverse the process using the new run capacitor to complete the repair.
Parts Used:
Refrigerator Capacitor
  • Burton from Pecatonica, IL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
Was this instruction helpful to you?
Thank you for voting!
Light switch in the refrigerator was faulty from the first day we installed the fridge.
I had ordered some other parts for something entirely different off your website and service was great. So after almost ten years of a dark refrigerator, because of a defective switch, I decided to see if you had the part to fix it... You did and the part got here in 3 days. I had a working light switch and all the light in the world where my husband needed it most (in the fridge). It took me at the most ten minutes to replace the part. All is well now and I have a happy husband who can find the leftovers just fine. Thanks for your great service!
Parts Used:
Refrigerator Door Switch
  • Mary from Wasilla, AK
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
light would come on and off
Viewed the viedo - it showed what to do
Parts Used:
Refrigerator Door Switch
  • Dora from Rock Island, IL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
Was this instruction helpful to you?
Thank you for voting!
Frig not cooling.
After plugging in the new relay to no avail. I replaced the thermostat. That fixed the problem.
Parts Used:
Refrigerator Capacitor
  • Adam from Randolph, ME
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers
Was this instruction helpful to you?
Thank you for voting!
Switch didn't work
followed the video as instructed. Saved two repairman calls, one to find the problem, one to install. Net savings was about $130.00
Parts Used:
Refrigerator Door Switch
  • Don from Laramie, WY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
Was this instruction helpful to you?
Thank you for voting!
Needed a new bulb under the microwave.
After unplugging the microwave and removing the screw, I removed the old bulb and put in the new one!! I made sure it was in securely and the difference in the light was awesome! I use this light when I bake bread and let it rise inside the microwave, but DO NOT turn it on. The heat from this light helps the bread to rise properly!!
Parts Used:
Light Bulb - 120V 25W
  • Norma from Unionville, MO
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
light switch sticking
I watched the video and thought "I can do this". Made some notes and then proceeded to remove the old switch and replace with the new one. Thank you.
Parts Used:
Refrigerator Door Switch
  • Paula from Rush, NY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
Was this instruction helpful to you?