Models > PSC23PSTS > Instructions

PSC23PSTS General Electric Refrigerator - Instructions

All Instructions for the PSC23PSTS
31 - 45 of 883
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Icemaker stripper arm tine broke off (by me), causing ice to remain and not discharge normally. The cause was a stripperarm tine becoming caught under an opposing tine in the icemaker preventing it from discharging ice altogether.
Installed the new stripper arm per instructions - an easy installation. After a few cycles the original problem happened again, the stripper arm tine caught under an opposing tine stopping the unit from operating. I removed the stripper arm, after marking where it was caught, and filed it down so it wouldn't catch anymore. Icemaker works fine now. Troubleshooting tip. If a stripper arm tine is caught under an opposing tine, gently slide a screwdriver between them to release it without breaking the tine. Remove the arm, file it down 1-3 mm, and reinstall.
Parts Used:
Icemaker Stripper Arm
  • Errol from Mill Creek, WA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
45 of 61 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker dispensed crushed ice but not cubes
Removed the ice bin and maker, then removed cover from the rear that covered the solenoid that controls the dispensing mechanism. Replace solenoid. The tricky part here is that there is a styrofoam cover around the solenoid pin that needs to be superglued into place and oriented properly during replacement. All electrical feeds snap out neatly and are easily replaced. Reassemble ice dispenser and bin, and viola, your back in business.
Parts Used:
Ice Dispenser Solenoid Service Kit
  • James from Greenville, NC
  • Difficulty Level:
    Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Nutdriver, Screw drivers
44 of 62 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The partion between the tub and dispenser broke
Once I got the correct part, (the expanded view of the icemaker is confusing as it shows the partition at the back of the diagram) I removed the ice dispenser from the tub by removing the screws and disengage the tabs holding the dispenser assembly in the tub. The most difficult step was getting the disenser disengaged from the tub. I used two kitchen knives to wedge between the walls of the tub. It was then easy to remove and replace the broken inside partition and reassemble the dispenser. Works like new.
Parts Used:
Housing Crusher Dispenser
  • Mark from Brandon, MS
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
36 of 41 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator Not Cooling due to ice buildup on coils
Removed shelves from freezer section and removed protective cover using a screwdriver and nutdriver. 5 screws.
Upon removal of the cover, I noticed the coils totally cover with ice. At this point I noticed that the defrost heater was burnt out. I removed the heater using screwdriver and pliers and tested the heater according to instructions from Parts Select website.
Since the coil was exposed, I also tested the defrost thermostat according to Parts select instructions and found it to be working properly. i also tested the defrost timer and found it OK.
I replaced the heater, closed the protective cover, replaced the shelves and plugged the unit on.
It has been working just fine since then..
In addition to saving money, i saved myself the agravation of looking for a repairman and having to wait for THEIR convenience to to the work.
Parts Used:
Defrost Heater and Bracket Assembly
  • FERNANDO from MIAMI, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers, Screw drivers
36 of 42 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water if refigerator door is really slow. Ice making is really slow.
Used by pass filter and problem disappeared. Of course wayer is now unfiltered. This is a GE design flaw. Also replacement filters are outrageously expensive and do not last long. We have good water here and I'll stick with the bypass.
Parts Used:
Refrigerator Bypass
  • Fred from Edgartown, MA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
41 of 60 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer would not defrost correctly
Took panel off back of inside of freezer section, took off old sensor from the evaporator, spliced new sensor into the existing wires, waterproofed spliced connections, snapped sensor back onto evaporator, then put panel back on the inside of the freezer. Really, it took only 10 minutes to fix. Now refrigerator defrosts like it used to, and temps have settled in at specified temps.
Parts Used:
Temperature Sensor
  • Michael from Milton, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers
32 of 34 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Plastic Drive Cup split
I took the four screws out of the ice basket and removed the plastic cup pieces. I then lifted the scress shaft up and put the new cup in. You have pull up very hard on the screw shaft and use two thin flat metal puddy knives to disingage the two plactic stays on each side of the shaft holder. The plactic housing around the screw shaft did not brake, however. I then put the screw shaft and the cup drive in place quite easily. Works fine.
Parts Used:
Ice Dispensing Drive Cup
  • Leroy from Cary, NC
  • Difficulty Level:
    Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Pliers, Screw drivers
34 of 41 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The compartment behind control panel with snow
I have unlock the black panel. With a screw driver I have removed 2 screws and removed 3 conectors from circuit board. So, I had access to solenoid set. From this point on was intuitive. Very easy.

I recomend these parts be replaced once time for each two years.
Parts Used:
Dispenser Door Solenoid Assembly Dispenser Door Assembly or Flapper Dispenser Door Recess Crank Recess Door Spring
  • Victor from Houston, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
40 of 61 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
ice despenser door would stick open and frost up to the point of of ice not coming out
after finding the video describing the same problem, i gave it a shot. Major problem was figuring out how to take outside trim off of the ice/water dispenser. Everything i tried did not work like the videos i had seen. Looking thru some of the posted blogs i found another way to get behind the control panel without even taking off the trim piece. i pressed a 1/8th allen wrench into the two outer holes on the bottom of the control panel which released the panel to pull out from the bottom. after that it was simple to release the three plugs from the circuit board and remove the control panel. 4 phi lips screws later the ice chute comes straight out revealing the flapper door which is held in by 2 more screws. once that assembly is out the solenoid is held by three more screws. there was nothing difficult at all about this repair once the secret was out about the first step about the three holes (use only the outer two) in the bottom of the control panel
Parts Used:
Dispenser Door Solenoid Assembly Dispenser Door Assembly or Flapper Door Recess Retainer Dispenser Door Recess Crank Recess Door Spring
  • joe from raleigh, NC
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
35 of 47 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Drive Cup Broke and Helix Cracked
Pulled Ice bin out and emptied ice out of bin. Removed 4 screws holding bin to frame and seperate bin from frame. Takeoff or loosen dispenser arm that has 1 screw holding it. On the sides in the front I pushed tabs in and pulled up on front auger/chip assembly area using two screwdrivers to hold tabs in. Pulling assembly up took a little pressure by hiting down on main ice bin to disengage and watching to see that tabs were also disengaged at same time. After that it was take c-clip off loosen nut and disassemble. You might want to draw a diagram as to how everything was in place or take a picture with your camera phone to make it alot easier for you to remember how everything went. Remove and Replace parts and assemble in reverse.Once you start to do it you'll see how it goes so easy, hopefully I didn't miss to many steps but if I did You'll see what needs to be done to go to the next step.
Parts Used:
Ice Dispensing Drive Cup Helix
  • Michael from Surprise, AZ
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Wrench (Adjustable)
32 of 40 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice & Ice Cream would melt and refreeze
Noticed the problem in November 2009. Replaced Hi Limit Sesor for Defrost thinking it was the freezor temperature sensor. Did not fix the problem. Replaced Motherboard. Did not fix the problem. Called Sears Repair. They mis-diagnosed the problem and told me it was the sealed system. I doubted them and sent them home. Replaced the correct freezer temperature sensor that connects to the motherboard. FIXED.
Removed a panel, cut two wires, soldered and insulated two wries, reinstalled panel.
Parts Used:
Temperature Sensor
  • Joe from Suffolk, VA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
30 of 34 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Cold water dispencer not working
Disconnect Refrigerator by unplugging from wall socket. Removed back access panel. Shutdown water supply to refrigerator. Have a backet and towels handy to catch residual water in lines. Unscrewed water valve assy. Push water line connectors inwards and remove plastic tubing. Using a wrench (or Adjustable wrench) remove incoming water supply line. Attach incoming water hose to new valve assy and push other two lines in valves. transfer the electrical conections.
Parts Used:
WATER VALVE WITH GUARD Crisper Cover Glass Insert
  • Vasilis from San ose, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers, Wrench (Adjustable), Wrench set
29 of 32 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water dispensor would not shut off
Actually this was a two part repair of which I purchased both parts. The micro switch Pt # PS296176 and also a double outlet water valve Pt # PS304374 from Parts Select as well.

The difficult part was accessing the area to get to the micro switch.

The trim had to be removed, then the cover.

Then one unplugs the board and removed the face plate which also contains the micro switch.

Once removed the two electrical terminals had to be disconnected, the micro switch installed and terminal reconnected.

Then reverse the removal procedure.

Then on to the double outlet replacement.

Suggest watching the installation video for the replacement although it was really a straight forward repair.

Two things to remember.

1. Unplug the fridge

2. Shut off the water to the dispenser

Overall it was not bad at all.

This was my first attempt at refrigerator repair and it went well.

Good luck on yours.

John
Parts Used:
Micro Switch
  • John from Mason, OH
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers, Wrench (Adjustable)
34 of 48 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker wouldn't dispense ice
ice tray slides right out. 4 philips to remove the bottom, 1 to remove the arm that controls the mode (regular vs. crushed). It just slips into a hole on a wheel at the dispenser end - the same end has two tabs you push in and slide up/out the coil screw that rotates and drives ice out. Once one end is out, it slips out, replace the cup, reverse. This is the 2nd time I've ordered from PartsSelect, both times the part came in just a couple of days, easy navigation on the site, plenty of security validation, etc.
Parts Used:
Ice Dispensing Drive Cup
  • Danny from Saint Augustine, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
29 of 36 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water is not coming from front door dispenser, but ice maker works well
On one severe winter cold night my fridge dispenser door stopped water supply, but ice maker was working. First I disconnected power supply to the fridge then turned off main water supply from the wall to fridge and with wrench set disconnected water supply pipe from wall to fridge while disconnecting the pipe make sure to collect the water from the both end pipes. Then removed the cardboard from the back side of the fridge. I disconnected the blue element (dispenser water) the red element (ice maker). [DOUBLE OUTLET WATER VALVE]. If you would try to pull the pipes white (dispenser water) and black (ice maker) you woudn't succeed because once the the white and black pipes are insereted into the water valve those pipes are clamped tightly in the valve. So I cut off those pipes and removed the old water valve, then I conncected the new water valve first conncected those white and blue elements and inserted the white and black pipes pushed in closed with round plactic caps comes with new one.I reconncected the main water supply pipes from wall to the frige and turned on the water supply from wall and plugged the power supply. First surpisingly I doubted it will work, actullay the water dispnser did'nt work immediately I have to wait 2 to 3 hours of time, in the mean time I checked the pipe connections from the bottom of the front left side door ( if you open the two doors bottom you can see the plastic cover it can be removed by pulling towards and pushing in you can close it back into normal position) which water supply pipe comes through the bottom of the door to water dispenser. I disconnected the connector and pusheed the dispensor several times to flushout any leaky water or air then I reconnected the pipes to the connector. I pushed the dispenser with a cup to dispenser, it started working as it is normally. While I was working my 7 years old son helped me as he always eager to learn and explore things.
Parts Used:
WATER VALVE WITH GUARD
  • BABU from GRAND PRAIRIE, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers, Wrench (Adjustable), Wrench set
26 of 31 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the PSC23PSTS