PIR23MGTABV General Electric Refrigerator - Instructions
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
No Ice
After verifying that my water solenoid valve did open and close (I removed the solenoid and put my own 120vac on it and blew through it) and then I verified that I was receiving my 120vac from the ice maker itself I knew my problem was in the ice maker itself. Just removed the mounting screws holding the old ice maker and it lifted out of place after unplugging the unit from electrical connection at the rear of the cabinet. Reversed the process for installation. Power unit up. Bleed air out of the water line feeding the watermaker. Waited a couple of hours and my first cubes where there. Filled up quick! Thanks.
Parts Used:
-
Michael from Calvin, LA
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver, Screw drivers
24 of 33 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fridge Door would not close "automagically"
I had to remove the fridge door (side by side), which took approximately 10min (most of which was retrieving the right size socket wrench from the garage). With the door removed, I could replace the broken door closing cam and door stop... with 4 screws. Not much to it. Had the door mounted back on in another 5min and that was it. :)
Parts Used:
-
David from Cary, NC
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers, Socket set
24 of 33 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
evertthing in frige was freezing
went online to an appliance repair site and found out that this model has problems with the damper malfunctioning. went to partselect and ordered what I needed and it arrived in two days. to replace the damper you just remove the light at the top of the frige and the cover around it . the damper assembly only has 2 screws and is easy to remove.
Parts Used:
-
justin from brownsville, OH
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers
19 of 24 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Cracked Housing Mount - water leak
Turned off the water. Removed the maintenance cover plate on the back of the refrigerator and disconnected the tubing. Removed the tubing cover plate on back of refrigerator. Removed two screws from filter hosing mount on the inside of the refrigerator and pulled the old tubing out. Simply inserted the new tubing and mounted the housing and reconnected the tubing using plumber’s pipe compound. Then re-installed the cover plates on the back of the refrigerator, installed the filter and turned on the water. It was a very easy install.
Parts Used:
-
Richard from Chandler, AZ
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers, Socket set
19 of 25 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker busted
There's a plastic cup part in the very rear of the ice bucket, that fits around the corkscrew thing that moves the ice toward the front of the bucket, where it can either get chopped up for crushed ice or just drop down as whole cubes as the case may be.
Well, that cheap plastic thing busted on our ice maker shortly after we bought it. Why GE chooses such thin, flimsy plastic for this important part is beyond me. I decided to replace the entire bucket assembly, for $105 rather than just the plastic part that was broken for $30. I never did figure how to take the thing apart to remove and replace that one part anyway. GE direct was expensive, so I finally found Part Select and was pleased to see that the bucket assembly was available for significantly less. When it arrived, I simply slid out the old ice bucket and slid in the new one. Voila! It's great to be able to have crushed, let alone any ice, automatically generated, again.
Well, that cheap plastic thing busted on our ice maker shortly after we bought it. Why GE chooses such thin, flimsy plastic for this important part is beyond me. I decided to replace the entire bucket assembly, for $105 rather than just the plastic part that was broken for $30. I never did figure how to take the thing apart to remove and replace that one part anyway. GE direct was expensive, so I finally found Part Select and was pleased to see that the bucket assembly was available for significantly less. When it arrived, I simply slid out the old ice bucket and slid in the new one. Voila! It's great to be able to have crushed, let alone any ice, automatically generated, again.
Parts Used:
-
Jeff from Temecula, CA
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
17 of 19 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
low water flow from in door water dispenser
after changing the water filter and having no improvement. I went to the next part of the system. Turned off the water supply. I removed the bottom cover in the back of the refrigerator. unscrewed the nuts on the water supply hose from the main supply and the one going back into the fridge. moved to the inside of fridge and unscrewed two screws holding the filter mount and pulled the tubing through. Reversed my steps and the water flow was great . Thanks
Parts Used:
-
kevin from summerville, SC
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver, Pliers, Screw drivers
17 of 20 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Add and Ice maker to a Kenmore Refridgerator
Ordered the complete kit minus the water tap. Should have ordered that also. Install was difficult simply because I was not sure of the style of the fridge. No ident had been left on the unit, so I used the p;ictures in the install kit to decide the proper install. Was very quick and the parts were great. After I went under the house(crawl space) I found an old water tap which broke off in my hand and started spewing water. Replaced everything and it runs great. Nice kit with a lot of instructions. Fantastic ordering fromyour company. Next day delivery was unexpected.
Parts Used:
-
Philip from Cape May, NJ
-
Difficulty Level:A Bit Difficult
-
Total Repair Time:30 - 60 mins
-
Tools:Pliers, Screw drivers, Wrench set
18 of 24 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
freezer freezing up
Unplug refrigerator,remove the freezer bulb, trays and rear cover to expose coils and heating element/defroster, The telltale sign its bad was it looked like an old flashbulb/burned, the old one was open, melt enough ice to remove and replace the defrost element(2 screws 2 wires) and reinstall components, reconnect power, thats it.
Parts Used:
-
richard from cleburne, TX
-
Difficulty Level:Really Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Screw drivers
16 of 21 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Iced up Freezer compartment in SxS
So I replaced a burnt out defrost heater; replaced the thermostat for good measure and STILL the freezer compartment was freezing up. WHY didn't I look more closely at the ice making system sooner!!?? Thought about it for a while and decided that it had to be that the solenoid in the water valve was NOT shutting off water flow to ice maker (overflowing the icemaker and running over & down interior of freezer compartment making an icberg).
Took off about 4-5 backcover screws with one size nut driver. Moved to a size larger driver to remove 1 screw holding on the water valve. And what some people don't realize is that you can push in the connectors (push them down) and THEN pull the water lines out as long as you're careful and someone hasn't already tugged on the waterlines with some force. You don't have to cut the lines off at the valve. Put the water lines in the new valve and put one screw back in it; then 4-5 backcover screws and you're done!!! At most 15 minutes...that is if you want to clean the condensor unit located behind the backcover (on the newer models within the last 4-6 years).
EASY!!! Do it yourself and save a BUNCH of money. If you're getting a flooded freezer compartment or icebergs created in there then check whenever you hear the icemaker drawing in water and see if water is running down the interior.....problem solved!
Took off about 4-5 backcover screws with one size nut driver. Moved to a size larger driver to remove 1 screw holding on the water valve. And what some people don't realize is that you can push in the connectors (push them down) and THEN pull the water lines out as long as you're careful and someone hasn't already tugged on the waterlines with some force. You don't have to cut the lines off at the valve. Put the water lines in the new valve and put one screw back in it; then 4-5 backcover screws and you're done!!! At most 15 minutes...that is if you want to clean the condensor unit located behind the backcover (on the newer models within the last 4-6 years).
EASY!!! Do it yourself and save a BUNCH of money. If you're getting a flooded freezer compartment or icebergs created in there then check whenever you hear the icemaker drawing in water and see if water is running down the interior.....problem solved!
Parts Used:
-
Jamison from Heltonville, IN
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
15 of 18 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
My 13 yr grandson assisted me on this
We couldn't get the other connector loose from one end of the tubing so he said just cut it and so we did and attached the connector. I now have water again in my fridge and took the sticky note down "don't use the water" as it had leaked for a year...... Thanks!
Parts Used:
-
Sherry from Auburn Hills, MI
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
15 of 18 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer Cold Refrigerator warm
The defrost heater failed. The coils frosted completely over so no airflow to the fridge. Step 1. Empty the freezer. Ice maker and top shelf can stay. Remove power, pull plug or open breaker. Step 2. Remove shelves and bottom food drawer. Step 3. Remove bottom food drawer rails. 2 phillips screws on each side. Step 4. Remove back panel, 2 screws at the top. Work panel out. Note there may be a green ground wire hook on it at the top. This will expose the heater and the cooling coils. The heater is at the bottom of the cooling coils and is the width of the coils. Step 5. There will be 2 wires, one on each end, and two phillips screws holding it in. Wires pull straight out. Note which way the heater is installed and remove the 2 screws. Step 6. Assemble in reverse order. Be very careful with the heater. It is in a glass tube and is very easy to break.
Parts Used:
-
Steve from DOWS, IA
-
Difficulty Level:Really Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Nutdriver, Screw drivers
13 of 13 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator side gets colder than set temperature. Plastic damper door broken in Fresh Food Air Inlet.
There were not detailed instructions provided with the parts, however, it was fairly simple to determine how to remove the old part. First, I removed all the shelves. Then I took out four screws holding the top light cover. The plasic around the back center column was removed with a pannel tool. The plastic around the water filter was also removed. The old Fresh Food Air Inlet was then able to come out. Remove the connector. Reinstall per instructions provided. Install the other parts in order they were removed.
Parts Used:
-
Robert from Hurst, TX
-
Difficulty Level:Easy
-
Total Repair Time:30 - 60 mins
-
Tools:Screw drivers
12 of 13 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Interior light needed replaced
Unplugged the appliance for safety. Removed two 1/4" screws that held the assembly in place. Carefully removed the wire guard that retains the glass shield. Unscrewed old light bulb and replaced with new part. Reversed the steps after cleaning glass cover.
Parts Used:
-
Leo from TWIN FALLS, ID
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Nutdriver
22 of 43 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
no water from door water dispenser and valve chattered
Removed water filter and turned off water supply. Remove the metal plate at the rear bottom of refrigerator and the metal plate at the top rear of the refrigerator that covers the exit of the filter housing from the refrigerator. Then disconnected the water supply line and water line from the filter housing mount to the valves that control water to the door and ice maker. From inside the refrigerator, removed the two bolts holding the filter housing and then removed the filter housing and tubing. Reversed the procedure to install the new top filter housing mount with tubing.
Parts Used:
-
Arthur from Richmond, VA
-
Difficulty Level:Easy
-
Total Repair Time:15 - 30 mins
-
Tools:Nutdriver, Screw drivers, Wrench set
14 of 20 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
slow water flow in dispenser
opened refrigerator door located water filter location in right back corner unscrewd 1/2 turn and out it comes without shutting off water it is a snap to do by anyone and shipment was really quick thanks. People do not call a service tech for something this simple even a child tall enough can do it.
Parts Used:
-
dwight from phoenix, AZ
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
14 of 21 people
found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!