Condenser fan not working. Freezer & frig heating up
Very limited working space in this model. Must remove grill and disconnect elect connector on motor. One additiional tool suggested: Extendable rod with magnet on end because you will most likely drop something. First, remove two screws holding motor to metal strap. Tool must be inserted between blades of fan in order to get to the screws and this is the hard part. Fan and motor are removed as one assy and this takes some manuvering. Might have to remove front screw on metal strap to gain more room. I did not attempt to remove fan shroud. My fan was attached to the motor shaft with a metal clip. Spray a good lubricant such as PB Blaster on the shaft, wait a few minutes and press it or tap it out gently. Save misc parts on old motor for reassembly. Your set up may be different so check out everything before starting.
Parts Used:
DC Condenser Fan Motor - 12V
  • Edward from New Smyrna Beach, FL
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Socket set, Wrench set