light bult needed to be replaced
The nightmare was that this microwave is installed under the cabinet....in order to get to the light bulb I had to pull out my stove then squeeze into the space between the stove and counter....my old microwave light bult was much easier to change.....Shame on Whirlpool for making this so difficult.....must be a better way to cover the light bulb so that we do not need a screwdriver to remove the door to get to the light bulb
Parts Used:
Light Bulb - 40W
  • Deborah from Millersville, MD
  • Difficulty Level:
    Difficult
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
220 of 325 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
bulb had broken off in base that was still screwed into socket
At first I tried to use pliers to unscrew the base,very uncomfortable working position,upside down and backwards(the microwave is installed over the range top)very limited space for your body and arms to manuver and you really cant see the base,all of this took place after the breaker was turned off ofcourse,finally figured out that you can drop the entire bottom housing of the microwave by unscrewing 6 screws and the light sockets are easily accessable once you lower it,take out 1 retaining screw ,remove the entire socket and unscrewed the broken base and replaced the bulbs,I said bulbs,there is no sense in having to replace another bulb in who knows how long since only one had burned out but they were both the same age
Parts Used:
Light Bulb - 40W 130V
  • william from san antonio, TX
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
93 of 109 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Unit worked fine except it would not heat
Had to take unit off wall and disassemble the main casing.then disconnected the wires from the magnetron.took the mounting nuts off but wasn't able to remove the magnetron until I loosened the transformer out of the way .Then it came out easy.Installed the magnetron ,tightened the nuts,installed the transformer back in, connected the the wires back on and installed the casing on ,screwed the screws and got help to install the unit to the wall again.....Tested the unit before putting back on the wall to make sure it heated....The parts were exac same type and wasn't too hard to do...
Parts Used:
Magnetron
  • Roy from Colorado Springs, CO
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers, Socket set
88 of 96 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Bulb "burnt out"
Removed 1 screw, removed "burnt out" bulb and replaced it with new bulb.
Parts Used:
Light Bulb - 40W
  • Joseph from Pembroke, MA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
96 of 160 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Microwave worked intermittently depending on how door was closed
Remove top grille (2 screws), undo control panel (1 screw). Tilt down control panel, switches are on the left. There are actually three switches that are involved with the door, two horizontally mounted, one vertically mounted. This would be an EASY REPAIR, but it took me a while to figure out which of the three switches was bad, and also took a while to figure out that there is a plastic rod that inserts through the hole in the switch body. Once i figured this out went like a breeze. Lower horizontal switch was the bad one, but since the kit came with two switches i went ahead and replaced the upper horizontal one as well. IT appears that the horizontal switches are probably more likely to fail than the vertical switch based on the position of the switch and force angles. Works great now!
Parts Used:
Door Interlock Switch Kit
  • Robert from Bainbridge Island, WA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers, Screw drivers
67 of 85 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Oven wouldn't heat
Over the range microwave. Replaced magnetron. Completely disassemble the case top and bottom.
Remove screws from bottom of HV transformer. Magnetron will not clear without this removal.

Remove nuts with socket from top of Magnetron. Remove thermo unit from old magnetron and attach it to new. Replace and bolt down Mag. Replace and screw in HV transformer. Make sure all wires are reconnected.

Put it back up on the wall. Took about three hours from taking it down from wall and putting it back up.
Parts Used:
Magnetron
  • CARTER from OXNARD, CA
  • Difficulty Level:
    Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Nutdriver, Screw drivers, Socket set
37 of 39 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
oven wouldn't heat
1. remove microwave from wall
2. remove cover (many screws)
3. remove nuts holding magnetron in place (4)
4. remove magnetron (this is a pain due to the plastic molding used to direct cooling air through the magnetron
5. get new magnetron in place (this was even more fun to find the right angles to tilt to get the magnetron to fit
6. re-tighten the 4 nuts on the magentron
7. put the cover back on
8. put the unit back on the wall.

bonus repair: the display flickered while the magnetron was on (cooking ) prior to the magnetron dying. found a ribbon cable on the control board to the display with an aluminum foil shield that had peeled off (adhesive failure). re-installing the aluminum shield with packaging tape, and the display no longer flickers
Parts Used:
Magnetron
  • david from elmira, NY
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Screw drivers, Wrench set
44 of 60 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
burned out bulb
removed two screws,lowered the glass shield,removed the burned out bulb and replaced it with the new one. I ordered the bulb from parts select and recieved it two days later. It was a pleasure to deal with them, and certainly use them again.
Parts Used:
Light Bulb - 40W
  • john from plainfield, IL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
28 of 39 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
microwave oven blew fuse
First I removed upper front grill by removing two Philips head screws on top and pulling off. This exposed the Philips head screw which holds control panel in place. After removing screw I pushed up on panel and it came off to expose fuse. With needle nose pliers I removed old fuse and again with pliers held new fuse in position. With the help of a bladed screwdriver, I pushed new fuse into holder, then replaced panel, screw and grill. This took less than 15 minutes even as one of the wires on control panel pulled out of connection and took some time to locate where to reconnect, otherwise was an easy fix
.
Parts Used:
Ceramic Fuse - 20 amp
  • tad from tamarack, MN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
27 of 42 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Burned out light bulbs in microwave hood stove
I had some difficulty removing the glass plate because of the awkward (upside down) position of the screw that retained it. After replacing the burned out bulbs and replacig the glass plate the problem of replacing the screw involved my dropping the thing several times before I got the screw threads to catch. I got a screw thread to catch enough to hold the glass plate in position and left it at that.
Parts Used:
Light Bulb - 40W
  • Herbert from Norton, MA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
24 of 35 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
blown dual element lightbulb
The hard part was trying to find the light bulb locally. The locally sold light bulbs were either too long, not dual element or not powerful enough. So I ordered the light bulb straight from PartSelect. When it came time to install the new light bulb I carefully removed the screw holding the plate in position so as not to loose it in my gas stove. I needed the mirror to line up the light bulb and screw it in. Once it was in I verified operation and closed up the plate being careful not to drop the screw into my gas stove. Problem solved.
Parts Used:
Light Bulb - 40W
  • Glenn from BRISTOW, VA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers, Wrench set
19 of 25 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Changing the bulb that illuminates the cooktop
Loosen screw holding glass cover plate in place over bulb. Glass cover plate will swing down. Unscrew bad bulb, replace with good bulb, reset glass cover and tighten screw.
Parts Used:
Light Bulb - 40W 130V
  • LUCY from BALLWIN, MO
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
21 of 33 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Microwave stopped working it lost complete power
Upon taking the faceplate off (unplugged power source first) I found one of the wires going to the THERMO SW-TCO SENSE TEMP was completely burned away. I cut back the wire and spliced a new section with heat shrink connectors and I replaced the THERMO SW-TCO SENSE TEMP. I plugged the power back in and it works great.
Parts Used:
Thermal Fuse
  • Thomas from HAMPTON BAYS, NY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
18 of 26 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Close the door on the microwave, punch in the # nothing happened
I removed the unit from the wall. Took the cover off. Set the unit on its side. It revealed the working parts. Removed the old micro switches. Put in the new oness. Presto, it worked. Very easy for me.
The parts was delivered almost before my notice they were shipped.
Parts Used:
Door Interlock Switch Kit
  • Robert S. from Stafford, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
15 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Both bulbs burned out at same time
I r/r the bulb cover, I then removed the burned out bulbs w/ a rag in case they broke they wouldn't have cut my fingers. You turn the bulbs lefty loosy. Installation is just the reverse. Install each bulb and turn righty titey, just snug the bulbs into place. Replace Glass cover and insert one phillips screw in plate and re-tighten
Parts Used:
Microwave Light Bulb - 40W
  • JOHN C from NORTH BEACH, MD
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
18 of 36 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the MVH230E