LT103HNR (AWYBHDP) LG Air Conditioner - Overview

Sections of the LT103HNR

[Viewing 1 of 1]
Keep searches simple, eg. "belt" or "pump".
Fan Assembly,Axial – Part Number: 5900AR1173A
Fan Assembly,Axial
PartSelect #: PS3528606
Manufacturer #: 5900AR1173A
$58.25
  Special Order
Capacitor – Part Number: EAE43285408
Capacitor
PartSelect #: PS3620459
Manufacturer #: EAE43285408
$65.95
  On Order
Escutcheon – Part Number: 3831A10044B
Escutcheon
PartSelect #: PS3522256
Manufacturer #: 3831A10044B
  No Longer Available
Frame – Part Number: 4918A20001A
Frame
PartSelect #: PS3524156
Manufacturer #: 4918A20001A
$36.95
  Special Order
REMOTE CONTROLLER ASSEMB – Part Number: 6711A20066L
REMOTE CONTROLLER ASSEMB
PartSelect #: PS3636484
Manufacturer #: 6711A20066L
$57.15
  Special Order
Louver,Vertical – Part Number: 4758A20009A
Louver,Vertical
PartSelect #: PS3523369
Manufacturer #: 4758A20009A
$50.95
  Special Order
Louver,Vertical – Part Number: 4758A20009B
Louver,Vertical
PartSelect #: PS3523370
Manufacturer #: 4758A20009B
$10.95
  Special Order
Room Air Conditioner Fan Bracket – Part Number: 4960A20005A
Room Air Conditioner Fan Bracket
PartSelect #: PS3524525
Manufacturer #: 4960A20005A
$46.15
  Special Order
Electric Heater – Part Number: 5300A20003A
Electric Heater
PartSelect #: PS3527720
Manufacturer #: 5300A20003A
  No Longer Available
Clamp,Spring – Part Number: 3H02932B
Clamp,Spring
PartSelect #: PS3522762
Manufacturer #: 3H02932B
The fan blade clamp, also known as a clamp spring, are for air conditioners. The clamp supports the fan blade on the motor shaft. When the motor is running, it signals the shaft to turn and rotate, bu...
$10.29
  Special Order
Damper,Compressor – Part Number: 4H00982C
Damper,Compressor
PartSelect #: PS3525491
Manufacturer #: 4H00982C
  No Longer Available
FILTER,AIR – Part Number: 5230A20007D
FILTER,AIR
PartSelect #: PS7785417
Manufacturer #: 5230A20007D
This part is the replacement air filter for your room air conditioner. It is framed by white plastic and is approximately 18 inches wide and 8.5 inches long. The air filter protects your home from air...
$35.27
  Special Order
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Motor mount broke due to imbalance caused by mud dobber nests.
Pulled PTAC out of wall sleeve, unhook wire harness from control area, remove condenser shroud and motor and fan blade all at the same time. Replaced motor bracket and re-installed in reverse order.
Parts Used:
Room Air Conditioner Fan Bracket
  • Travis from LOUISVILLE, IL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Capacitor went out
Unplugged and replugged everything and it worked very easy job thank you
Parts Used:
Capacitor
  • Al from CROSS PLAINS, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers, Screw drivers
2 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
fan had stripped out and was replacing.
very tight working situations. made a mistake with a delicate piece of the fan and broke it and that rendered the part unuseful. Since I broke it I considered it to be my fault and just threw it away. Ordered another from another company hoping that just maybe it would be more durable. It arrived in only 4 days. Yours took well over a week to arrive. Thanks for asking for my experience.
Parts Used:
Fan Assembly,Axial
  • Douglas from ENGLEWOOD, TN
  • Difficulty Level:
    Very Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Pliers, Screw drivers, Socket set
1 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!